Home Automation OmniPro II Zone Event Buttons, All On/Off Event Buttons, UPB Link Event Buttons

Page 71

AREA:

0=ALL

ENTER AREA

The area number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of areas.

WHEN C1 A1 AWAY: 1=DELAY 2=CODE 3=AREA

Zone Event Buttons

Pressing the 3 (ZONE) key allows you to select the event button for a zone activation event. You are first prompted to enter the desired zone number:

ZONE:

ENTER ZONE

The zone number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of zones. The desired zone is then displayed and you are prompted to specify the state that activates the event button:

WHEN Front Door:

0=SECURE

1=NOT RDY

All On/Off Event Buttons

Pressing the 4 (ALL) key allows you to specify an event button activated by issuing an All On or an All Off command, issuing a Leviton Scene command, or issuing a UPB Link command. You are first prompted to specify whether the event button is for All Lights On, All Off, Leviton Scene, or UPB Link:

ALL

0=OFF 1=ON 2=SCN 3=LINK

If area arming is being used, you will be prompted to specify the desired area:

AREA:

0=ALL

ENTER AREA

If Leviton Scene is selected, you must first specify the scene number:

ENTER SCENE: 1-256

Then select the specified command Off, On, or Set.

If UPB Link is selected, you must first specify the link number:

ENTER LINK: 1-250

Then select the specified command Off, On, or Set.

UPB Link Event Buttons

When a program is created that uses “When Link On” as the trigger, the program will execute when a “Link Activate”, “Link Goto” (as long as the result of the Goto command is not “0”), or “Link Fade Start” (as long as the result to the Fade command is not “0”) message is received.

When a program is created that uses “When Link Off” as the trigger, the program will execute when a “Link Deactivate” or “Link Goto” (where the result of the Goto command is “0”) message is received.

Using HAI PC Access Software, you can create a program that uses “When Link Fade Stop” as the trigger. When this trigger is used, the program will execute when the “Link Fade Stop” message is received.

Page 63

Image 71
Contents Document Number 20R00-2Rev. January HOME AUTOMATION, INCControl & Security System All Rights Reserved Copyright 2001-2006Home Automation, IncContents INTRODUCTIONOVERALL DESCRIPTION SECURITY SYSTEM OPERATIONCONTROL TELEPHONE CONTROL SETUP APPENDIX A - DIAL OUT PLANNER UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE CANADIAN INDUSTRY CANADA NOTICEPage Page INTRODUCTIONUnderwriters Laboratories UL Listing 2- DAY OVERALL DESCRIPTIONConsole Operation 1- OFF7- CONSOLE LED Normal Top-LevelDisplayDisplay Menus 6- UP ARROWTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsConfirmation Beep OmniPro II MaintenanceCancel Areas1 = DAY SECURITY SYSTEM OPERATIONArming the Security System 0 = OFF4 = VACATION Using Shortcut Keys2 = NIGHT 3 = AWAYRestoring Zones 9 = RESTOREQuick Arm Bypassing Zones#=GOTO What To Do When You Come HomeWhat Happens When the Alarm is Activated Burglar Alarm ActivatedPage Fire Alarm ActivatedGas Alarm Activated Emergency KeysPolice Emergency Duress Code Entered or Duress Alarm ActivatedAlarm Reset Alarm CancelPage Trouble IndicationsCodes Master CodeManager Code Panic SwitchesDuress Code Area ArmingPage GOTO AreaPage Testing Your SystemPage Control CommandsCONTROL About UPBAbout Rooms When set to UPB, the OmniPro II controller canRoom Controller LED Indicators HAI Lighting Control HLC FormatPage About CentraLiteAbout Lutron RadioRA About House ControllersALC Module Types About ALCAbout House CodesPage Unit NumbersOmniPro II Unit Numbers Module / Output Unit NumbersControlling a Room of HLC Lighting Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling UnitsPage StepOperation Controlling CentraLite UnitsPage Controlling RadioRA UnitsControlling ALC or X-10Units Page Ramp Command ALCScene Command Compose Controlling Compose UnitsPage Timed CommandsStatus of a Unit Internal FlagsAll Off Controlling OutputsAll On / Off All Lights OnLeviton Scene Control Scene CommandsScene Set Command Scene On CommandActivating and Deactivating Links Scene Off CommandSetting a Link Lighting Scenes UPB LinksPHANTOM BUTTON 1 0=OFF 1=ON Executing Phantom ButtonsExecuting CentraLite Scenes ENTER BUTTONDinner for Two Button ButtonsTemperature Control Leave for Work ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsPage Freeze AlarmsIMPORTANT NOTES Indoor and Outdoor TemperatureTemperature Control of Appliances Temperature AlarmsHumidity Outdoor TemperaturePage Configuring HLC DevicesConfiguring HLC Devices using an Omni Console StatusStep Operation Setup Mode for HLC DevicesStep Operation Step OperationDEAD - DEAD PHONE LINE ONHK - ON HOOKOFFHK - OFF HOOK RING - RINGINGPage THROUGHPage Event LogShow Events Clear Text Messages MessagesRecord Memo Message Play Memo MessageSay Message Show MessageLog Message Clear MessageENTER MESSAGE Send Message Pro-LinkSERIAL PORT MSGNAMERemote Phones TELEPHONE CONTROLTelephone Interface In-HousePhonesPage Phone Access Denied - Remote LockoutAlternate Method Main Menu4 - All 1 - Control2 - Security 3 - Button7 - Events When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 6 - StatusPaging and Listening When the HAI Two-WayAudio Module is being used8 - Message Playing and Recording a MessagePage 9 - Good-ByePanic Button over the Phone # # # # # # Playing and Recording the AddressHow the OmniPro II Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerPage PC AccessWhat You Hear - If Your OmniPro II Calls You Entering the CodePage Connecting to Network via PC AccessBuilt-InEthernet Port OmniPro II Ethernet ConnectionsPage Local NetworkDynamic DNS Page Local / Wide Area Networki.e i.eAuthority Level SETUPSet Up Codes Access AreasPage Set Up TimeDuress Code TIMEPage Advanced Control Programming ACP1 = Add Programs 2 = Show ProgramsPage MenuPage Edit Programs3 = Delete All Programs Page Edit Programs WhenTimes Programs Page Control Unit / Switch Press Event ButtonsButton and Event Programs UPB 6-ButtonKeypad Corresponding Switch TableSwitch OmniProPage Zone Event ButtonsAll On/Off Event Buttons UPB Link Event ButtonsPage Alarm Event ButtonsX-10Event Buttons Miscellaneous Event ButtonsPage Switch Press Event Buttons CentraLiteMessage Event Buttons Pro-Link Page Edit Program CommandProgram Control Commands Program All On / All Off Commands Unit Toggle CommandProgram Security Commands Program Button CommandsProgram Energy Cost Program Video CommandsProgram Message Commands Program Temperature CommandsProgram Zone Conditions Edit Program ConditionProgram Control Conditions Program Security Mode ConditionsPage Program Time Clock ConditionsProgram Other Conditions Answer Outside Call Set Up DialTelephone Access Remote CommandsPage Dial Out NumberDial Out Numbers Dial OrderAudible Exit Delay Set Up ArmingEntry Delay Exit DelayAll On For Alarm Set up MiscellaneousEnable Quick Arm Enable Auto BypassFORMAT Enable Freeze AlarmFlash For Alarm House Codes 1-16FormatPage House Codes 1-16All OnTime Clocks Page Latitude, Longitude, and Time ZoneZONE NAME Daylight SavingsDESCRIPTION Controller IP AddressController Port Number NUMBERPage Set Up NamesEncryption Key 4=CODE 5=TEMP 6=AREA 8=MSG↑ Set Up VoiceSet Up Address SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓Page UNDERWRITERS LABORATORIES REQUIREMENTSFIRE ESCAPE PLANNING Page FEDERAL COMMUNICATION COMMISSION NOTICEPage CANADIAN INDUSTRY CANADA NOTICEIF YOU HAVE TROUBLE WITH YOUR PHONES Page APPENDIX A - DIAL OUT PLANNEROmniPro II Voice Dial-OutPlanner Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESCODE DESCRIPTIONDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODECODE NOTES ON CUSTOM PHRASESCODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER