Home Automation OmniPro II Set up Miscellaneous, Enable Quick Arm, Enable Auto Bypass, Page

Page 82

Enable Quick Arm

The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter your code.

The default setting for Enable Quick Arm is No.

Enable Auto Bypass

The Auto-Bypassfeature allows the system to automatically bypass an open zone when the system is armed, rather than setting off the alarm. In some applications, it may be preferable to allow arming only if all zones are secure (READY).

With Auto-BypassOff, all zones to be armed must be secure when the system is armed. Otherwise, the console will beep three times and display "ZONE NOT RDY". If the system is armed and a zone is open when the Exit Delay expires, the alarm will sound.

All On For Alarm

This option will instruct OmniPro II to execute an X-10 All On command in the event that any type of alarm occurs.

Beep On Trouble

If the OmniPro II detects any troubles with itself or one of the zones connected to it, it will display a message on the screen and beep the console twice per second, continuously (i.e. beep beep...beep beep...). You can silence this sound by pressing the ' * ' key. However, if the trouble occurs again, the beeper will start beeping again.

If you do not wish to hear the beeping sound when a trouble occurs, set Beep On Trouble to No.

The default setting for Beep On Trouble is Yes.

Set up Miscellaneous

To configure Miscellaneous items in the system, from the Set Up menu, press the 6 (MISC) key.

High Security Mode

In High Security Mode, the Master or Manager code is always required to do the following functions:

Any Control functions

Any Temperature Control

View the Event Log

Access the system from a local phone

With High Security Mode Off, no code is required to access a local telephone.

If your system is set up with High Security Mode On, the display will request the Master or Manager code whenever you select one of these functions, even if the security system is Off. Simply enter your Master or Manager code.

Your system was shipped from the factory with High Security Mode Off, which allows you to view the event log and access the local phones without having to enter a code. In most residential applications, this is appropriate. If you have a commercial installation, or would like added protection from unauthorized access to the system, you may wish to turn on High Security Mode.

Announce Alarms

If a Two-Way Audio Module is being used in a system, this item enables the system to speak the type of alarm and zone over a speaker on premises. When an alarm first occurs, the siren is activated. After a few seconds, the siren is turned off and the type of alarm is announced. The siren is then reactivated.

The default for Announce Alarms is No.

Page 74

Image 82
Contents Control & Security System HOME AUTOMATION, INCDocument Number 20R00-2Rev. January Copyright 2001-2006Home Automation, Inc All Rights ReservedSECURITY SYSTEM OPERATION INTRODUCTIONOVERALL DESCRIPTION ContentsCONTROL TELEPHONE CONTROL SETUP CANADIAN INDUSTRY CANADA NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE APPENDIX A - DIAL OUT PLANNERPage Underwriters Laboratories UL Listing INTRODUCTIONPage 1- OFF OVERALL DESCRIPTIONConsole Operation 2- DAY6- UP ARROW Normal Top-LevelDisplayDisplay Menus 7- CONSOLE LEDTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyAreas OmniPro II MaintenanceCancel Confirmation Beep0 = OFF SECURITY SYSTEM OPERATIONArming the Security System 1 = DAY3 = AWAY Using Shortcut Keys2 = NIGHT 4 = VACATIONBypassing Zones 9 = RESTOREQuick Arm Restoring ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated #=GOTOEmergency Keys Fire Alarm ActivatedGas Alarm Activated PageAlarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Police EmergencyMaster Code Trouble IndicationsCodes PageArea Arming Panic SwitchesDuress Code Manager CodeGOTO Area PageTesting Your System PageAbout UPB Control CommandsCONTROL PageHAI Lighting Control HLC Format When set to UPB, the OmniPro II controller canRoom Controller LED Indicators About RoomsAbout House Controllers About CentraLiteAbout Lutron RadioRA PageHouse Codes About ALCAbout ALC Module TypesModule / Output Unit Numbers Unit NumbersOmniPro II Unit Numbers PageControlling Units Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling a Room of HLC LightingControlling CentraLite Units StepOperation PageControlling ALC or X-10Units Controlling RadioRA UnitsPage Controlling Compose Units Ramp Command ALCScene Command Compose PageInternal Flags Timed CommandsStatus of a Unit PageAll Lights On Controlling OutputsAll On / Off All OffScene On Command Scene CommandsScene Set Command Leviton Scene ControlUPB Links Scene Off CommandSetting a Link Lighting Scenes Activating and Deactivating LinksENTER BUTTON Executing Phantom ButtonsExecuting CentraLite Scenes PHANTOM BUTTON 1 0=OFF 1=ONLeave for Work Button ButtonsTemperature Control Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageIndoor and Outdoor Temperature Freeze AlarmsIMPORTANT NOTES PageOutdoor Temperature Temperature AlarmsHumidity Temperature Control of AppliancesStatus Configuring HLC DevicesConfiguring HLC Devices using an Omni Console PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationRING - RINGING ONHK - ON HOOKOFFHK - OFF HOOK DEAD - DEAD PHONE LINETHROUGH PageShow Events Event LogPage Play Memo Message MessagesRecord Memo Message Clear Text MessagesClear Message Show MessageLog Message Say MessageMSGNAME Send Message Pro-LinkSERIAL PORT ENTER MESSAGEIn-HousePhones TELEPHONE CONTROLTelephone Interface Remote PhonesMain Menu Phone Access Denied - Remote LockoutAlternate Method Page3 - Button 1 - Control2 - Security 4 - All6 - Status When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 7 - EventsPlaying and Recording a Message When the HAI Two-WayAudio Module is being used8 - Message Paging and ListeningPlaying and Recording the Address 9 - Good-ByePanic Button over the Phone # # # # # # PageVoice Dialer Emergency Dial-OutDigital Dialer How the OmniPro II Voice Dialer WorksEntering the Code PC AccessWhat You Hear - If Your OmniPro II Calls You PageOmniPro II Ethernet Connections Connecting to Network via PC AccessBuilt-InEthernet Port PageDynamic DNS Local NetworkPage i.e Local / Wide Area Networki.e PageAccess Areas SETUPSet Up Codes Authority LevelTIME Set Up TimeDuress Code Page2 = Show Programs Advanced Control Programming ACP1 = Add Programs PageMenu Page3 = Delete All Programs Edit ProgramsPage Times Programs Edit Programs WhenPage Button and Event Programs Control Unit / Switch Press Event ButtonsPage OmniPro Corresponding Switch TableSwitch UPB 6-ButtonKeypadUPB Link Event Buttons Zone Event ButtonsAll On/Off Event Buttons PageMiscellaneous Event Buttons Alarm Event ButtonsX-10Event Buttons PageMessage Event Buttons Pro-Link Switch Press Event Buttons CentraLitePage Program Control Commands Edit Program CommandPage Program Button Commands Unit Toggle CommandProgram Security Commands Program All On / All Off CommandsProgram Temperature Commands Program Video CommandsProgram Message Commands Program Energy CostProgram Security Mode Conditions Edit Program ConditionProgram Control Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsPage Remote Commands Set Up DialTelephone Access Answer Outside CallDial Order Dial Out NumberDial Out Numbers PageExit Delay Set Up ArmingEntry Delay Audible Exit DelayEnable Auto Bypass Set up MiscellaneousEnable Quick Arm All On For AlarmHouse Codes 1-16Format Enable Freeze AlarmFlash For Alarm FORMATTime Clocks House Codes 1-16All OnPage Daylight Savings Latitude, Longitude, and Time ZoneZONE NAME PageNUMBER Controller IP AddressController Port Number DESCRIPTIONEncryption Key Set Up NamesPage SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ Set Up VoiceSet Up Address 4=CODE 5=TEMP 6=AREA 8=MSG↑FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSPage FEDERAL COMMUNICATION COMMISSION NOTICE PageIF YOU HAVE TROUBLE WITH YOUR PHONES CANADIAN INDUSTRY CANADA NOTICEPage OmniPro II Voice Dial-OutPlanner APPENDIX A - DIAL OUT PLANNERPage INSTRUCTIONS TO CALLED PARTY PageCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARDESCRIPTION APPENDIX C - VOICE DESCRIPTION CODESCODE CODECODE CODEDESCRIPTION DESCRIPTIONCODE CODEDESCRIPTION DESCRIPTIONDESCRIPTION NOTES ON CUSTOM PHRASESCODE CODEPage NOTE TO INSTALLER HAI New Orleans, LA U S A