Trouble Indications

The OmniPro II constantly monitors the alarm zones and several internal matters and will alert you if it detects trouble. The particular trouble is indicated on the bottom line of the display and a trouble signal is given by beeping the console beeper continuously, 2 beeps per second.

When any trouble condition occurs, the console will beep twice per second and continue to beep until the ' * ' key (cancel) is pressed to acknowledge the trouble. The console will say "TRBL NOW" (trouble now) if the trouble condition actually exists while you are looking at the console. It will say "HAD TRBL" (had trouble) if the trouble occurred and then corrected itself.

The following are trouble indications and their meanings:

¾ZONE NAME TRBL NOW or HAD TRBL: If the reading for a zone becomes abnormal, trouble will be indicated on that zone -SeeStatus \ Test. Excessive resistance in the contact and wiring usually causes trouble on security zones. If the cause is not obvious, call your installer for service.

¾AC POWER OFF TRBL NOW or HAD TRBL: Indicated if the normal house current powering the OmniPro II controller is interrupted for more than 3 minutes. If this happens without good cause, check the wall mounted transformer to ensure that it hasn't come out of the wall socket and check to see that the socket has power.

¾BATTERY LOW TRBL NOW or HAD TRBL: Every hour, the OmniPro II takes a dynamic test of the battery. If the battery voltage is too low, then the console will indicate "BATTERY LOW". If this happens, make sure that the battery is connected. The "BATTERY LOW" indication will remain until the next battery test is executed, 1 hour later, or when a Status Test command is given.

¾COMMUNICATOR TRBL NOW or HAD TRBL: Indicated if the digital communicator (not the voice dialer) was unable to make contact with the Central Station after trying both numbers multiple times. If this happens, there could be a problem with the system, central station, or the phone line. Call your installer for service.

¾FUSE TRBL NOW or HAD TRBL: Indicated when the solid state fuse that protects the "Auxiliary" power supply opens. The fuse will automatically reset when the fault condition is cleared.

¾PHONE LINE DEAD TRBL NOW or HAD TRBL: Indicated if the phone line is dead for more than 1 minute.

To silence the trouble beeps on the console, press the ' * ' key. If more than one type of trouble has occurred, the display will show each one for two seconds. Pressing the ' * ' key will acknowledge all trouble indications.

If the trouble condition occurs again, the console beeper will beep again - See Set Up Arming, Beep On Trouble if you wish to disable the beeper.

¾NO CONTROLLER DATA: Indicated when console's alarm functions are no longer operational. This may indicate a wiring problem to the console or a more serious problem. Call your installer for service.

Codes

There are 99 user codes that you may assign to users of the system. All OmniPro II codes are 4 digits in length. A code can be any number from 0001 to 9999. Each user should be assigned a security code with an authority level, areas that can be accessed (if area arming is used), and times and days in which the code will be valid. Memorize your codes! Don't give them to anyone who doesn't need to know them.

The levels of authority that you can assign to a user code are Master, Manager, and User.

Master Code

The Master code allows complete access to the entire system. Only the owner(s) or the one(s) who will govern the system should have and use the master code. A Master code is allowed access to all areas, all the time.

User code 1 is always set to a Master code - See Set Up Codes.

Page 12

Image 20
Contents Document Number 20R00-2Rev. January HOME AUTOMATION, INCControl & Security System Copyright 2001-2006Home Automation, Inc All Rights ReservedINTRODUCTION OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL SETUP UNDERWRITERS LABORATORIES REQUIREMENTS FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage Page INTRODUCTIONUnderwriters Laboratories UL Listing OVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniPro II Maintenance CancelAreas Confirmation BeepSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys PageDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code PagePanic Switches Duress CodeArea Arming Manager CodeGOTO Area PageTesting Your System PageControl Commands CONTROLAbout UPB PageWhen set to UPB, the OmniPro II controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsAbout CentraLite About Lutron RadioRAAbout House Controllers PageAbout ALC AboutHouse Codes ALC Module TypesUnit Numbers OmniPro II Unit NumbersModule / Output Unit Numbers PageConfiguring Lighting Scenes in an HLC Room Scrolling Through NamesControlling Units Controlling a Room of HLC LightingStep OperationControlling CentraLite Units PagePage Controlling RadioRA UnitsControlling ALC or X-10Units Ramp Command ALC Scene Command ComposeControlling Compose Units PageTimed Commands Status of a UnitInternal Flags PageControlling Outputs All On / OffAll Lights On All OffScene Commands Scene Set CommandScene On Command Leviton Scene ControlScene Off Command Setting a Link Lighting ScenesUPB Links Activating and Deactivating LinksExecuting Phantom Buttons Executing CentraLite ScenesENTER BUTTON PHANTOM BUTTON 1 0=OFF 1=ONButtons Temperature ControlLeave for Work Button Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageFreeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature PageTemperature Alarms HumidityOutdoor Temperature Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStatus PageSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINETHROUGH PagePage Event LogShow Events Messages Record Memo MessagePlay Memo Message Clear Text MessagesShow Message Log MessageClear Message Say MessageSend Message Pro-Link SERIAL PORTMSGNAME ENTER MESSAGETELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Page1 - Control 2 - Security3 - Button 4 - AllWhen an HAI Communicating Thermostat is entered When a Programmable Energy Saver PESM is entered6 - Status 7 - EventsWhen the HAI Two-WayAudio Module is being used 8 - MessagePlaying and Recording a Message Paging and Listening9 - Good-Bye Panic Button over the Phone # # # # # #Playing and Recording the Address PageEmergency Dial-Out Digital DialerVoice Dialer How the OmniPro II Voice Dialer WorksPC Access What You Hear - If Your OmniPro II Calls YouEntering the Code PageConnecting to Network via PC Access Built-InEthernet PortOmniPro II Ethernet Connections PagePage Local NetworkDynamic DNS Local / Wide Area Network i.ei.e PageSETUP Set Up CodesAccess Areas Authority LevelSet Up Time Duress CodeTIME PageAdvanced Control Programming ACP 1 = Add Programs2 = Show Programs PageMenu PagePage Edit Programs3 = Delete All Programs Page Edit Programs WhenTimes Programs Page Control Unit / Switch Press Event ButtonsButton and Event Programs Corresponding Switch Table SwitchOmniPro UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsUPB Link Event Buttons PageAlarm Event Buttons X-10Event ButtonsMiscellaneous Event Buttons PagePage Switch Press Event Buttons CentraLiteMessage Event Buttons Pro-Link Page Edit Program CommandProgram Control Commands Unit Toggle Command Program Security CommandsProgram Button Commands Program All On / All Off CommandsProgram Video Commands Program Message CommandsProgram Temperature Commands Program Energy CostEdit Program Condition Program Control ConditionsProgram Security Mode Conditions Program Zone ConditionsPage Program Time Clock ConditionsProgram Other Conditions Set Up Dial Telephone AccessRemote Commands Answer Outside CallDial Out Number Dial Out NumbersDial Order PageSet Up Arming Entry DelayExit Delay Audible Exit DelaySet up Miscellaneous Enable Quick ArmEnable Auto Bypass All On For AlarmEnable Freeze Alarm Flash For AlarmHouse Codes 1-16Format FORMATPage House Codes 1-16All OnTime Clocks Latitude, Longitude, and Time Zone ZONE NAMEDaylight Savings PageController IP Address Controller Port NumberNUMBER DESCRIPTIONPage Set Up NamesEncryption Key Set Up Voice Set Up AddressSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑Page UNDERWRITERS LABORATORIES REQUIREMENTSFIRE ESCAPE PLANNING FEDERAL COMMUNICATION COMMISSION NOTICE PagePage CANADIAN INDUSTRY CANADA NOTICEIF YOU HAVE TROUBLE WITH YOUR PHONES Page APPENDIX A - DIAL OUT PLANNEROmniPro II Voice Dial-OutPlanner INSTRUCTIONS TO CALLED PARTY PageAPPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTION CODES CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONNOTES ON CUSTOM PHRASES CODEDESCRIPTION CODEPage NOTE TO INSTALLER HAI New Orleans, LA U S A