Home Automation OmniPro II Controlling Outputs, All On / Off, All Lights On, All Off, Page

Page 34

Controlling Outputs

The OmniPro II has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 385-392, respectively. If the Interior Horn is configured as a "General Purpose" output, Unit Number 393 is used to control the output. If the Exterior Horn is configured as a "General Purpose" output, Unit Number 394 is used to control the output. In this configuration, Unit Numbers 393 and 394 should not be used as "Flags".

These 12 VDC voltage outputs are connected directly to the OmniPro II and not through a module. If you have something connected to these outputs, such as a sprinkler system, your dealer will explain its operation.

Outputs cannot be brightened or dimmed and are not affected by All ON or All Off commands.

All On / Off

The All On/Off menu is used to turn all unit numbers in the specified House Codes on and off.

Note: UPB, CentraLite, and RadioRA devices are not affected by the OmniPro II “All On” or “All Off” command. To achieve this functionality, we suggest the following:

UPB: Program a Link into each device that will respond to an OmniPro II “All On” and “All Off” command program. For example:

In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that will go to 100% when activated (turned on). Then write the following programs in the OmniPro II controller:

WHEN ALL ON: LINK 50 ON

WHEN ALL OFF: LINK 50 OFF

CentraLite: Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on the CentraLite.

RadioRA: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).

For example:

WHEN ALL ON: PHANTOM BUTTON 16 ON

WHEN ALL OFF: PHANTOM BUTTON 17 ON

This All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes. From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad.

ALL

0=OFF 1=ON 2=SCN 3=LINK

ALL

4=PHANTOM 5=CENLIT

All Lights On

At the ALL prompt, press the 1 (LIGHTS ON) key. The console will beep, and a command will be sent that turns on all specified X-10 and ALC units and HLC Rooms. X-10 Appliance Modules do not respond when the All Lights On command is sent. All House Codes (1-16), by factory default, respond to the All-On command.

NOTE: The All On function can be changed, if desired - See Set Up Misc, All On And All Off.

All Off

At the ALL prompt, press the 0 (OFF) key. The console will beep, and a command will be sent that turns off all specified X-10 and ALC units and HLC Rooms. All House Codes (1-16), by factory default, respond to the All-Off command.

Page 26

Image 34
Contents Control & Security System HOME AUTOMATION, INCDocument Number 20R00-2Rev. January Copyright 2001-2006Home Automation, Inc All Rights ReservedSECURITY SYSTEM OPERATION INTRODUCTIONOVERALL DESCRIPTION ContentsCONTROL TELEPHONE CONTROL SETUP CANADIAN INDUSTRY CANADA NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE APPENDIX A - DIAL OUT PLANNERPage Underwriters Laboratories UL Listing INTRODUCTIONPage 1- OFF OVERALL DESCRIPTIONConsole Operation 2- DAY6- UP ARROW Normal Top-LevelDisplayDisplay Menus 7- CONSOLE LEDTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyAreas OmniPro II MaintenanceCancel Confirmation Beep0 = OFF SECURITY SYSTEM OPERATIONArming the Security System 1 = DAY3 = AWAY Using Shortcut Keys2 = NIGHT 4 = VACATIONBypassing Zones 9 = RESTOREQuick Arm Restoring ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated #=GOTOEmergency Keys Fire Alarm ActivatedGas Alarm Activated PageAlarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Police EmergencyMaster Code Trouble IndicationsCodes PageArea Arming Panic SwitchesDuress Code Manager CodeGOTO Area PageTesting Your System PageAbout UPB Control CommandsCONTROL PageHAI Lighting Control HLC Format When set to UPB, the OmniPro II controller canRoom Controller LED Indicators About RoomsAbout House Controllers About CentraLiteAbout Lutron RadioRA PageHouse Codes About ALCAbout ALC Module TypesModule / Output Unit Numbers Unit NumbersOmniPro II Unit Numbers PageControlling Units Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling a Room of HLC LightingControlling CentraLite Units StepOperation PageControlling ALC or X-10Units Controlling RadioRA UnitsPage Controlling Compose Units Ramp Command ALCScene Command Compose PageInternal Flags Timed CommandsStatus of a Unit PageAll Lights On Controlling OutputsAll On / Off All OffScene On Command Scene CommandsScene Set Command Leviton Scene ControlUPB Links Scene Off CommandSetting a Link Lighting Scenes Activating and Deactivating LinksENTER BUTTON Executing Phantom ButtonsExecuting CentraLite Scenes PHANTOM BUTTON 1 0=OFF 1=ONLeave for Work Button ButtonsTemperature Control Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageIndoor and Outdoor Temperature Freeze AlarmsIMPORTANT NOTES PageOutdoor Temperature Temperature AlarmsHumidity Temperature Control of AppliancesStatus Configuring HLC DevicesConfiguring HLC Devices using an Omni Console PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationRING - RINGING ONHK - ON HOOKOFFHK - OFF HOOK DEAD - DEAD PHONE LINETHROUGH PageShow Events Event LogPage Play Memo Message MessagesRecord Memo Message Clear Text MessagesClear Message Show MessageLog Message Say MessageMSGNAME Send Message Pro-LinkSERIAL PORT ENTER MESSAGEIn-HousePhones TELEPHONE CONTROLTelephone Interface Remote PhonesMain Menu Phone Access Denied - Remote LockoutAlternate Method Page3 - Button 1 - Control2 - Security 4 - All6 - Status When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 7 - EventsPlaying and Recording a Message When the HAI Two-WayAudio Module is being used8 - Message Paging and ListeningPlaying and Recording the Address 9 - Good-ByePanic Button over the Phone # # # # # # PageVoice Dialer Emergency Dial-OutDigital Dialer How the OmniPro II Voice Dialer WorksEntering the Code PC AccessWhat You Hear - If Your OmniPro II Calls You PageOmniPro II Ethernet Connections Connecting to Network via PC AccessBuilt-InEthernet Port PageDynamic DNS Local NetworkPage i.e Local / Wide Area Networki.e PageAccess Areas SETUPSet Up Codes Authority LevelTIME Set Up TimeDuress Code Page2 = Show Programs Advanced Control Programming ACP1 = Add Programs PageMenu Page3 = Delete All Programs Edit ProgramsPage Times Programs Edit Programs WhenPage Button and Event Programs Control Unit / Switch Press Event ButtonsPage OmniPro Corresponding Switch TableSwitch UPB 6-ButtonKeypadUPB Link Event Buttons Zone Event ButtonsAll On/Off Event Buttons PageMiscellaneous Event Buttons Alarm Event ButtonsX-10Event Buttons PageMessage Event Buttons Pro-Link Switch Press Event Buttons CentraLitePage Program Control Commands Edit Program CommandPage Program Button Commands Unit Toggle CommandProgram Security Commands Program All On / All Off CommandsProgram Temperature Commands Program Video CommandsProgram Message Commands Program Energy CostProgram Security Mode Conditions Edit Program ConditionProgram Control Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsPage Remote Commands Set Up DialTelephone Access Answer Outside CallDial Order Dial Out NumberDial Out Numbers PageExit Delay Set Up ArmingEntry Delay Audible Exit DelayEnable Auto Bypass Set up MiscellaneousEnable Quick Arm All On For AlarmHouse Codes 1-16Format Enable Freeze AlarmFlash For Alarm FORMATTime Clocks House Codes 1-16All OnPage Daylight Savings Latitude, Longitude, and Time ZoneZONE NAME PageNUMBER Controller IP AddressController Port Number DESCRIPTIONEncryption Key Set Up NamesPage SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ Set Up VoiceSet Up Address 4=CODE 5=TEMP 6=AREA 8=MSG↑FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSPage FEDERAL COMMUNICATION COMMISSION NOTICE PageIF YOU HAVE TROUBLE WITH YOUR PHONES CANADIAN INDUSTRY CANADA NOTICEPage OmniPro II Voice Dial-OutPlanner APPENDIX A - DIAL OUT PLANNERPage INSTRUCTIONS TO CALLED PARTY PageCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARDESCRIPTION APPENDIX C - VOICE DESCRIPTION CODESCODE CODECODE CODEDESCRIPTION DESCRIPTIONCODE CODEDESCRIPTION DESCRIPTIONDESCRIPTION NOTES ON CUSTOM PHRASESCODE CODEPage NOTE TO INSTALLER HAI New Orleans, LA U S A