SSA-S2100/SSA-S2101 has 4 input pins and 4 output pins installed(2 relay and 2 TTL outputs) The input pins can receive signals from the Exit button and the Door Contact sensor, while the two relays can be connected to the Door Lock and the alarm device. You can specify the output time for these output pins. (Refer to “I/O Wiring” on pages 17 to 18)

Holiday Scheduling

In total, 10 holiday schedule codes are available for SSA-S2100/SSA-S2101 models, and each holiday schedule code can be confi gured for up to 100 holidays except Sundays. Each holiday code can be linked to the time schedule code.

You can set all holidays to holiday schedule codes, and holiday schedule code is based on the holiday time zone for the time scheduling. (Refer to “Holiday Scheduling” on page 52)

Forced Door Open Alarm

You can set the Forced Door Open Alarm to activate when the door is opened by force.

For its application, you must have installed the door contact sensor and properly set the door contact time and output settings for the alarm device. The Forced Door Open Alarm lasts until the alarm event is terminated. (Refer to “Door Contact Sensor” on page 40)

ANTIPASSBACK

A door has two card readers installed: one for the entrance, and the other for the exit, so anyone who enters should recognize his/her card on the reader at the entrance time before he can exit normally. If a person does not go under the card recognition process and just follows another person’s way inside the door, the person is not allowed to exit when he/she recognizes the access card on exit card reader, and the antipassback error (APB error) occurs which will be saved into the internal memory. And you can configure to output a signal through a specific pin when such an error occurs. (Refer to “Antipassback Error Output Setup” at pages 46 and 49.)

Arm/Disarm

As long as the device is in Arm mode, the reader ports are all frozen so that no one can get access to the door and any input from the corresponding external pin will not be processed. In this mode, SSA-S2100/SSA-S2101 transmits a specific signal to the connected security devices so that they responds properly. (Refer to “Arm/Disarm” on page 37)

Door Open Timeout Alarm

The Door Open Timeout Alarm notifies the administrator of the fact with an alarm if a door stays open after the normal service time. The Door Open Timeout Alarm lasts until the door is closed.

(Refer to “Door Open Timeout Setup” on page 44)

Duress Alarm

This is used in a situation where you should open the door inevitably by a robber insisting to do so. Entering the two- digit duress alarm password with pressing the ENT button and recognizing the registered card (or card number) opens the door, while this forcibly unarmed situation will be notified to the PC application with an alarm event. (Refer to “Duress Mode” on page 36)

Two Men Operation Mode

In this mode, SSA-S2100/SSA-S2101 permits a certain person (visitor) to enter or exit only when accompanied by a special user (administrator). Both the visitor and the administrator should be authorized before they can get access. (Refer to “Registering the ID card” on page 32)

4 Levels of Individual Door Opening Time Setting

You can use this function to set 4 different door opening time points. (Refer to “Output Setup for Level IDs Accessing Reader” at pages 44 and 47.)

Name Display

SSA-S2100/SSA-S2101 can display the name of a person when the person is authorized to get access. (Refer to “Name Display” on page 25)

8_ product introduction

Image 8
Contents Standalone Rfid Access Controller Please visit our websiteSafety information Safety informationThis device may not cause harmful interference, Important Safety InstructionsSafety Information Contents Contents Event Memory Setup Voice Volume SetupInput Type Setup Default SettingsFeatures Product introductionExternal I/O Pins Forced Door Open AlarmDoor Open Timeout Alarm Duress AlarmWHAT’S Included Quick Guide CD ManualLCD AT a GlanceFront Panel Communication status indicator Pin Connector Preliminary connector for extensionRear Panel LEDCable Color Scheme PIN ConnectorPins Signal Cable Color TCP/IP RJ45 Connector Cable SelectionInstalling the Wall Mount Follow the instructions below to install the wall mountConnecting the Termination Resistor and Diode Bypass Diode ConnectionEARTH-GROUNDING the Communication Cables Host PCConnection Input ConnectionOutput Connection External Reader Connection External Reader ConnectionCommunication Line Connection RS-232 Communication Port ConnectionRS-485 Communication Port Connection Standalone RS-485 Communication Port Connection Multiple UnitsMax m Please follow the steps belowTCP/IP Communication Port Connection Connect all RS-485 ports of the product in parallelInitializing the system using the Initialize switch System Initialization in Master ModeInitialization Initializing the SystemTo register a master card To Access the Master ModeRegistering a Master ID 00/00 Name DisplayTo register a master card PIN User Count Setup Language SetupMAX User Setup € English € Espanol € PortugueseDATE/TIME Setup Communication Address SetupSET DATE/TIME Comm Addr SETBaud Rate Setup Factory DefaultsDefault SET Baud RateReader #2 Mode Reader mode setupReader #1 Mode € USE If set, you can get access using the keypad input Reader #1 KEY InputReader #2 KEY Input RD#1 KEY Input not USERegistering ID in Quick Mode Quick Mode RegistrationUser management To register IDRegistering the ID To register the ID cardSCANNING… PW TA TB C RD MA MB LV ID RegisteredTo register the PIN number To select PINSSA-S2101 Numeric letters in 4 ~ 8 or 10 digits PW TA TB C RD MA MB LV ID Registered User ManagementID List To Delete IDViewing the ID List ALL ID Clear To cancel the work, press the buttonTo delete all registered IDs Duress Mode Duress Mode Not USE Duress Password Enter Duress P/WTo delete all registered master IDs Master ID CLRDoor Open Alarm Time Setup ARM/DISARMOpen ALR Time User Management ARM/DISARM SETTWO MEN Operation Mode To move to the TWO MEN Mode itemTo Check the Number of Events To select USE or not USE, and press ENT . J not USETo Remove ALL Events To Remove the Time ScheduleTime setup Door Contact Sensor SetupExit Button Output Exit ButtonAuxiliary Input #1 Setup Auxiliary Input #2 SetupTime Setup AUX INPUT#1Tamper Alarm Output Setup CUT OFF Output SetupTamper Alarm CUT OFF AlarmDuress Mode Output Setup ARM/DISARM Output SetupDoor Open Timeout Setup Output Setup for Level IDs Accessing Reader #1Output Setup for Level 4 IDs Accessing Reader #1 Output Setup for Level 2 IDs Accessing Reader #1Output Setup for Level 3 IDs Accessing Reader #1 Reader #1 Error Output Setup Reader #1 ID Error Output SetupReader #1 Time Schedule Error Output Setup Reader #1 Antipassback Error Output SetupOutput Setup for Level IDS Accessing Reader #2 RD2 ID OK LV2Reader #2 Error Output Setup Output Setup for Level 4 IDs Accessing Reader #2Reader #2 ID Error Output Setup 12.RD2 ID ErrorReader #2 Time Schedule Error Output Setup Reader #2 Antipassback Error Output Setup13.RD2 T/S Error Time Setup 14.RD2 APB ErrorAdvanced setup Time Unit SetupOutput Time SCHEDULE+ID Time Unit Unit 1SEC Unit 0.1SECAntipassback Mode Time Schedule SetupAPB Mode Not USE ALL Clear Use the 4 Buttons to specify the interval, dayHoliday Setup Holiday Code Setup Holiday CodeCode 01 Code 10Reader Mode Time Schedule Reader #1 Mode Time Schedule Reader #2 Mode Time ScheduleRD1 Mode I T/S RD2 Mode I T/SOutput Time Schedule Setup Voice Message Time ScheduleVoice I T/S T/S Code ‘00’ means no Time Schedules are to be appliedCUT OFF SET Input Time Schedule SetupInput CUT OFF Check Setup ID Display Additional featuresEvent Memory Setup Wiegand Output Setup Voice Volume SetupVoice Volume Wiegand Output not USE Not USE The default setting for One Time Read is not USE ONE Time Read Not USE Jnot USE Additional FeaturesONE Time Read Version CheckInput Test Output TestLast Update LCD TestKeypad Test Press ANY KEYRAM TESTING… Reader TestMemory Test Reader Test SCANNING…Communication Test Comm TestO , 0 1 N C E X D C I 1 I 2 T P 0 0 0 0 0 0 0 0 0 Input Type SetupInput Type Other information Menu StructureMenu Structure of the F3 button F3 buttonMenu Structure of the F4 button F4 buttonOther Information Menu Structure of the F5 buttonF5 button Menu Structure of the F6 button F6 buttonMenu Structure of the F7 button Menu Structure of the F8 buttonMenu Structure of the F9 button F9 buttonMenu Structure of the F12 button F12 buttonDefault Settings Output Settings for Input SourcesDuress Alarm TTL#1 TTL#2Output Setting for Authentication Trouble Shooting TroubleshootingTroubleshooting Card Buzzer keeps beepingCommunication between Controller and the Host PC failsProduct Specifications Product specificationsCorrect disposal of batteries in this product