18
Part 3:
Install the control
A.
There are several different control options available for your
Choices are as follows:
DC1000: Manual,
DC4000: 24V Control Box that only works when the electricity is on. It Does NOT HAVE buttons.
DC5000: 24V Control Box that only works when electricity is on. Has buttons.
DC6000: 24V Pneumatic control box that will work without electricity by drawing upon the air built up in the compressor.
DC7000: 120V Pneumatic control box that will work without electricity by drawing upon the air built up in the compressor. Has large, red emergency buttons.
B.
Mounting and Electronic Control Box:
1.
Before installing control box (seen below), install all regulators, dryers etc.
Air line dryer
2.
Install control box near operator and 110V power supply. If not possible, the control box can be installed in equipment rooms, attics etc. Installing a Quick Dump Exhaust may be needed depending on the distance between the control box and the operators. The control box should be mounted
Note: Control Boxes require 110V AC power unless specified on the unit