2624

3.Lower the air pressure: Lower the air pressure to the operator. The door will not operate as quickly and the shock of the immediate reversal of the door won’t loosen the cables.

4.Restrict the air flow: Install a valve in the air line to restrict the airflow. This will slow the reaction time of the door and still maintain the desired air pressure.

5.Balance the door: Balance the door by checking spring tension or counterweight. If the springs are wound too tightly, or the counterweight is too heavy, the door may not come down properly and cable could get slack.

6.Cable keepers: This is a spring that attaches to the bottom roller shaft and hooks to the cable. It requires 11/4 inches of space between the door and the track.

7.Pusher springs: Pusher springs give a door stuck in the horizontal position a shove to get it started. These are available from most door companies, or call UPI at 1(800)542-7221.

800-542-7221 • 2319 Laurelbrook Street, Raleigh, NC 27604

Contact us if you have questions about installation or maintenance.Technical assistance and salespeople are available Monday through Friday between

9am and 5pm, Eastern Standard Time. Ultimate Products is

closed for national holidays.

1

Image 28
Contents  Necessary tools Supplies needed but not included with this kitPart 1BELT Installation Installing Tensioner Kit Before installing the air cylinder, Installing Tensioner Kit As shown on From belt before installing belt onto Operator Hanging Operator Page Page Setting Open and Close Door Limits Completed Operator set up view Installation Chain Drive Part 2INSTALLING Chain Drive Step Installing Chain Speed Control Kit Sprocket Assembly Part No. SPK1000 Step Completed Chain Operator set up, see Part Installing Air Lines Part 6a U Series Part 6b S Series Door adjustments and fine tuning Troubleshooting Install Signal SendersFixing Door or Operator Problems Fixing Control Problems Automatic Oiler Adjustment Cable Jumping Cable jumping solutionsDoor cable is jumping Putting the cable back on the drum2624 Model DC Model DC Model DC Home of the Best Buy Guarantee Photo Amplifier Wiring Directions Limit Switch Wiring and Mounting Suggested Installation of Magnetic Loop Wiring Diagram Finder Timer to Control Box Operator with Belt Operator with Chain Ring AP1004 Check ball Power Supply DimensionsControl Box ModelOperators Superior or Economy Air-Powered Operators Ultimate Air-Powered OperatorOperators with chains Operators with beltsOperators with Automatic Oilers Cylinder OilingOperators without Oiler Tools and materials needed Items included in the kitCup Seals Breather Vents and Check Ball Piston Rod SealsNeedle Valve Page Technical assistance and salespeople are available Monday