Ultimate Products UP-206 manual Control Box, Power Supply, Model, Mounting, Dimensions

Page 39

37

Architectural Guide for Air-Power Operator System

Control Box

— Power Supply :

110V Plug in type. Solenoid valve available in 24V or 110V. Always 24V unless specified otherwise.

— Model:

DC1000: Lever-operated, three-position air valve.

DC4000: Control box that only works when the electricity is on (no buttons).

DC5000: Control box that only works when the electricity is on.

DC6000: Control box that will work without electricity by drawing upon the air built-up in the compressor.

DC7000: Line voltage emergency open red button. Used with Autec equipment

Note: Control boxes interface with all car wash equipment and operate by pulse.

— Mounting:

Control Box may be mounted in the wash or equipment room. Specify a quick-dump exhaust AA1210 (additional cost) if the control box is more than 40 feet away from the air compressor.

— Dimensions:

DC1000: 8 1/4 inches tall, 6 inches deep, 3 1/4 inches wide

DC4000: 11 1/2 inches tall, 6 inches deep, 10 1/2 inches wide

DC5000: 11 1/2 inches tall, 6 inches deep, 10 1/2 inches wide

DC6000: 12 inches tall, 6 3/4 inches deep, 10 3/4 inches wide

DC7000: 11 1/2 inches tall, 7 inches deep, 9 1/2 inches wide

21

Image 39
Contents  Supplies needed but not included with this kit Necessary toolsPart 1BELT Installation Installing Tensioner Kit Before installing the air cylinder, Installing Tensioner Kit As shown on From belt before installing belt onto Operator Hanging Operator Page Page Setting Open and Close Door Limits Completed Operator set up view Installation Chain Drive Part 2INSTALLING Chain Drive Step Installing Chain Speed Control Kit Sprocket Assembly Part No. SPK1000 Step Completed Chain Operator set up, see Part Installing Air Lines Part 6a U Series Part 6b S Series Door adjustments and fine tuning Install Signal Senders TroubleshootingFixing Door or Operator Problems Fixing Control Problems Putting the cable back on the drum Automatic Oiler Adjustment Cable JumpingCable jumping solutions Door cable is jumping2624 Model DC Model DC Model DC Home of the Best Buy Guarantee Photo Amplifier Wiring Directions Limit Switch Wiring and Mounting Suggested Installation of Magnetic Loop Wiring Diagram Finder Timer to Control Box Operator with Belt Operator with Chain Ring AP1004 Check ball Model Power SupplyDimensions Control BoxOperators Operators with belts Superior or Economy Air-Powered OperatorsUltimate Air-Powered Operator Operators with chainsCylinder Oiling Operators with Automatic OilersOperators without Oiler Items included in the kit Tools and materials neededCup Seals Piston Rod Seals Breather Vents and Check BallNeedle Valve Page Technical assistance and salespeople are available Monday