Ultimate Products UP-206 manual Operators

Page 40

38

Operators

— Air Usage:

Uses 0.4 cubic feet of air to open and 0.4 cubic feet of air to close.

— Air Pressure:

Regularly set for 40-90 PSI.

— Air Line:

3/8 inch PolyFlow line

— Operator Placement:

The operator is normally mounted to the side of the track (either side).

For extremely cold climates, the operator may be mounted on the horizontal track.

— Drive Mechanism:

The rod coming out of operator is attached to chain or belt by collars and the chain/belt goes around a sprocket on the shaft.

A Model — A mild-steel chain. Use with non-corrosive environments. S Model Nickel-plated chain

UA Model — Belt: Steel-embedded polymer belt, similar to a motorcycle timing belt.

— Operator Lifting Ability:

An 8 foot operator indicates that the operator will raise the door 8 feet high: a 10 foot operator lifts 10 feet high, a 12 foot operator raises the door 12 feet high, and a 14 foot operator lifts the door 14 feet high.

— Dimensions:

8 foot operator — 58 1/4 inches tall, 4 3/4 inches deep, 6 1/2 inches wide 10 foot operator — 68 1/4 inches tall, 4 3/4 inches deep, 6 1/2 inches wide 12 foot operator — 78 1/4 inches tall, 4 3/4 inches deep, 6 1/2 inches wide 14 foot operator — 88 1/4 inches tall, 4 3/4 inches deep, 6 1/2 inches wide

22

Image 40
Contents  Necessary tools Supplies needed but not included with this kitPart 1BELT Installation Installing Tensioner Kit Before installing the air cylinder, Installing Tensioner Kit As shown on From belt before installing belt onto Operator Hanging Operator Page Page Setting Open and Close Door Limits Completed Operator set up view Installation Chain Drive Part 2INSTALLING Chain Drive Step Installing Chain Speed Control Kit Sprocket Assembly Part No. SPK1000 Step Completed Chain Operator set up, see Part Installing Air Lines Part 6a U Series Part 6b S Series Door adjustments and fine tuning Troubleshooting Install Signal SendersFixing Door or Operator Problems Fixing Control Problems Automatic Oiler Adjustment Cable Jumping Cable jumping solutionsDoor cable is jumping Putting the cable back on the drum2624 Model DC Model DC Model DC Home of the Best Buy Guarantee Photo Amplifier Wiring Directions Limit Switch Wiring and Mounting Suggested Installation of Magnetic Loop Wiring Diagram Finder Timer to Control Box Operator with Belt Operator with Chain Ring AP1004 Check ball Power Supply DimensionsControl Box ModelOperators Superior or Economy Air-Powered Operators Ultimate Air-Powered OperatorOperators with chains Operators with beltsOperators with Automatic Oilers Cylinder OilingOperators without Oiler Tools and materials needed Items included in the kitCup Seals Breather Vents and Check Ball Piston Rod SealsNeedle Valve Page Technical assistance and salespeople are available Monday