Limit Switch Wiring and Mounting
Track
Top of door
Step 2:
Lead side of limit switch & bracket
1/2”
Magnet & L-bracket
Step 3:
Black wire goes to 3 on electric eye
Black wire goes
amplifier.
to 4 on electric eye amplifier.
Red wire goes to open on control box terminal strip.
Step 1:
Remove existing wire on amplifier between terminal 3 and open