Ultimate Products UP-206 manual Part 6b S Series

Page 23

21

Part 6a: U Series

Door speed adjustments and fine tuning continued.

Note: Only for U series operators

B. Door slows too soon when closing

Step 1- Speed control valve closest to wall controls down. Follow same procedure as Part A, Step 2.

C. Door opens slowly and closes rapidly.

Step 1- If counter weights are available, add more weight if necessary. For doors with springs you may need to add more tension.

D. Door goes halfway and stops

Step 1- Check the door itself to make sure nothing is binding the door. Also check speed control valves to make sure they are adjusted properly.

Part 6b: S Series

Door speed adjustments and fine tuning

Note: Only for S series operators

A. Door Slows Down too Soon When Opening:

1.Locate the airflow control screw on the bottom of the up cylinder (farthest from the wall).

2.Turn the airflow control valve one complete turn counter clockwise or until the door operates properly.

Note: Use caution: Unscrewing too far will cause it to come out. When screwing it back in, pay attention to the two holes adjacent to each other on the bottom cap. Placing the screw in the wrong hole causes the loss of the cushioning effect. The correct hole has threads.

B. Door Opens too Quickly (Bangs or Slams Into Upper Limit):

1.Locate the airflow control screw on the bottom of the up cylinder (farthest from the wall).

2.Turn the airflow control screw one complete turn clockwise or until the door operates properly.

Image 23
Contents  Supplies needed but not included with this kit Necessary toolsPart 1BELT Installation Installing Tensioner Kit Before installing the air cylinder, Installing Tensioner Kit As shown on From belt before installing belt onto Operator Hanging Operator Page Page Setting Open and Close Door Limits Completed Operator set up view Installation Chain Drive Part 2INSTALLING Chain Drive Step Installing Chain Speed Control Kit Sprocket Assembly Part No. SPK1000 Step Completed Chain Operator set up, see Part Installing Air Lines Part 6a U Series Part 6b S Series Door adjustments and fine tuning Fixing Door or Operator Problems Install Signal SendersTroubleshooting Fixing Control Problems Putting the cable back on the drum Automatic Oiler Adjustment Cable JumpingCable jumping solutions Door cable is jumping2624 Model DC Model DC Model DC Home of the Best Buy Guarantee Photo Amplifier Wiring Directions Limit Switch Wiring and Mounting Suggested Installation of Magnetic Loop Wiring Diagram Finder Timer to Control Box Operator with Belt Operator with Chain Ring AP1004 Check ball Model Power SupplyDimensions Control BoxOperators Operators with belts Superior or Economy Air-Powered OperatorsUltimate Air-Powered Operator Operators with chainsOperators without Oiler Cylinder OilingOperators with Automatic Oilers Cup Seals Items included in the kitTools and materials needed Needle Valve Piston Rod SealsBreather Vents and Check Ball Page Technical assistance and salespeople are available Monday