Samsung ASV24PUQXXEA Using the Smart Saver function, If the air conditioner is on, Timer 1 hour

Page 15

 

 

 

 

If the air conditioner is on

 

 

 

 

 

 

Ex) On timer : 3 hours,

timer : 1 hour

Ex) On timer : 3 hours,

timer : 5 hours

-

 

- The air conditioner will operate On timer after 3 hours

1 hour from the moment you have set the timer.

from the moment you have set the timer.

Your air conditioner will turn on after 2 hours.

Your air conditioner will remain on for 2 hours and then

 

 

 

 

• On and timer setting time should be from each other.

• Press the Set/Cancel button on the remote controller while timer combination is on.

Using the Smart Saver function

This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode.

Press the SmartSaver button on the remote controller while the air conditioner is operating in Cool mode.

Smart Saver indicator and air swing indicator appears automatically on the remote controller display.

If the current set temperature is lower than 24°C, it will automatically raise to 24°C.

Cancel Press the Smart Saver button once again.

• Smart Saver function is only available in Cool mode.

• When Smart Saver function is activated, temperature range will be limited to 24°C~30°C.

If the desired temperature is lower than 24°C, turn the Smart Saver function by pressing the Smart Saver button again.

Temperature/Fan speed can also be adjusted (see page 11 for instructions).

Aircan be adjusted manually (see page 12 for instructions).

If you press the Mode button while the Smart Saver function is on, it will cancel the function.

USING THE SPi FUNCTION < FOR SPi MODEL >

SPi, Super-Plasma Ion, generates hydrogen(H) and oxygen(O2) to remove a polluted substance and decomposition of such harmful particles. It makes you breathe better as if you were staying around waterfalls, ocean surf, rivers and mountains.

1.Press the SPi button on the remote control.

SPi indicator will appears on the remote control display and the air conditioner generates SPi.

• The SPi mode can be selected whether the air

• The SPi mode will be on automatically when you turn on the air conditioner.

To deactivate SPi mode

1. Press the SPi button on the remote control. SPi mode you set will be canceled.

ENGLISH

15

Image 15
Contents Air Conditioner Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperaturePosition you prefer Using the Turbo functionPress the Air swing button on the remote controller Circulate the airMode Press the button Press the button to set the time Press the Set/Cancel button to active it onFrom the moment you have set the timer Using the Smart Saver functionTimer 1 hour Timer 5 hoursUsing the Quiet function Heat exchanger Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelDry the Ai lter in a ventilated area Cleaning the air conditionerClean the Air Slide it downPeriodical checks Maintaining the air conditionerTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter If may not be aConnection Model Name Included Models Remark General informationWon’t be considered in-warranty and charged to end user Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerModel Outdoor UnitWhen installing more than 1 outdoor unit  When the air outlet is towards the wallTop view Side view Accessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Connecting the cableFix the indoor unit Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryThen pull it out through the appropriate hole Smooth the cut edgesConnect the pipes Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Correct InclinedCracked Applying the following torqueChanging direction of the drain hose Drain hose installationExcessive torque can be cause of gas leakage Purging the connected pipesAdding Refrigerant Covered by the Kyoto Protocol 1975Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitProperly Model Outdoor unit installed on the wall by rackFixing the outdoor unit in place Part without insulation on the end of the pipesFinal Check and Trial Operation Pump down procedure when removing the productPress the Power button and check the following Press the Mode button to select Cool or Heat modeHow to connect your extended power cables Questions or COMMENTS?