Samsung ASV13PSPXXEA Connecting the assembly cable, Connecting the cable, Fix the indoor unit

Page 28

Fixing the installation plate

2. Fix the indoor unit.

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20mm.

Plastic

Anchor

<20mm

Wall

(1)

Determine the positions of the wooden uprights to be

(1)

 

 

attached to the window frame.

(2)

Fix the plate hanger on two studs.

(2)

Attach the wooden uprights to the window frame giving

 

 

 

attention to the weight of the indoor unit.

 

 

(3)

Attach the installation plate to the wooden upright using

 

 

 

tapping screws.

 

 

Search for other spots if there are less than two studs, or the distance between the studs are from the

plate hanger.

Fix the installation plate without inclining to one side.

Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not

strong enough to withstand the product weight, the unit could fall and cause injury.

Connecting the assembly cable

If using a multi system, install as described in the installation manual supplied with the outdoor unit.

Model

Power cable

 

Interconnection cable

Type GL

 

 

 

 

 

 

 

 

 

 

10/13

3G, 1.0mm² H05VV-F

4G, 1.5mm² H07RN-F

20A

18/24

3G, 2.5mm² H07RN-F

3G, 1.0mm² H07RN-F

25A

2, 0.75mm² H05RN-F

 

 

 

 

 

 

• Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of ≥3mm.

Connecting the cable

Electrical work

1)For electrical and earth works, comply with the ‘technical standards of electrical installations’ and the the ‘wiring regulations’ of the Electricity Enterprises Act.

2)Tighten the terminal block screw to under 12kgf.cm.

3)Precautions when connecting terminal blocks of the indoor unit

Before connecting, make sure the connecting part of the terminal socket is facing upwards.

Upside down

The terminal socket

There is no ring terminal

is damaged.

to cover the wire.

 

28

Image 28
Contents Air Conditioner Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressUsing the Turbo function Press the Air swing button on the remote controllerCirculate the air Position you preferMode Press the Set/Cancel button to active it on Press the button Press the button to set the timeUsing the Smart Saver function Timer 1 hourTimer 5 hours From the moment you have set the timerUsing the Quiet function Cleaning the indoor unit Cleaning the outdoor unit heat exchangerOpening the panel Heat exchangerCleaning the air conditioner Clean the AirSlide it down Dry the Ai lter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting If may not be a Outdoor unit Heat exchanger during Heat mode in winterConnection General information Model Name Included Models RemarkChoosing the installation location Installing the unitPower supply line, fuse or circuit breaker Won’t be considered in-warranty and charged to end userOutdoor Unit Model When the air outlet is towards the wall When installing more than 1 outdoor unitTop view Side view Accessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableFix the indoor unit Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Then pull it out through the appropriate holePurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Connect the pipesCorrect Inclined CrackedApplying the following torque Outer DiameterDrain hose installation Changing direction of the drain hosePurging the connected pipes Excessive torque can be cause of gas leakageAdding Refrigerant 1975 Covered by the Kyoto ProtocolPerforming the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesOutdoor unit installed on the wall by rack Fixing the outdoor unit in placePart without insulation on the end of the pipes Properly ModelPump down procedure when removing the product Press the Power button and check the followingPress the Mode button to select Cool or Heat mode Final Check and Trial OperationHow to connect your extended power cables Questions or COMMENTS?