Samsung ASV24PSPNXEA, ASV13PSPNXEA, ASV18PSPXXEA manual Extend the assembly cable if necessary

Page 29

There must be no space between the terminal and the screw when connected.

The terminal socket

is upside down. or there is a space between the screw and the ring terminal.

• For the terminal block wiring, use a wire with a ring terminal socket only.

CAUTION

ng work.

￿When you install the unit, make refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, disconnect electrical cables, then refrigerant connections.

If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable.

The maximum length of the cable is 15(** 10/13 ** )/ 30( ** 18/24 ** ) meters.

1. Extend the assembly cable if necessary.

Do not connect two or more cables to extend the length.

It may cause

2 . Open the front grille.

3 . Remove the screw securing the connector cover.

4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)

• Each wire is labeled with the corresponding terminal number.

5 . Pass the other end of the cable through the 65mm hole in the wall.

6 . Close the connector cover by tightening the screw carefully.

7 . Close the front grille.

8 . Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture.

ENGLISH

Indoor unit

18/24

10/13

Indoor unit

Indoor unit

Outdoor unit

 

Outdoor unit

 

 

Outdoor unit F1 F2

*

 

F1 F2

F1

F2

• Also circular terminal must be matched with screw size in terminal block.

• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.

10.Connect the grounding conductor to the grounding terminals.

11.Close the terminal board cover by tightening the screw carefully.

• In Russia and Europe, consult with the supply authority to determine the supply system impedance before

 

installation.

 

Connect the wires according to color codes, referring to the wiring diagram.

 

The power cable and the interconnection cable should be selected according to the

in page 28.

29

Image 29
Contents Air Conditioner Contents Important safety symbols and precautions Safety precautionsFollow directions Wall socketFor Using For Cleaning Operation ranges Checking before useChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperaturePress the Air swing button on the remote controller Using the Turbo functionCirculate the air Position you preferMode Press the button Press the button to set the time Press the Set/Cancel button to active it onTimer 1 hour Using the Smart Saver functionTimer 5 hours From the moment you have set the timerUsing the Quiet function Cleaning the outdoor unit heat exchanger Cleaning the indoor unitOpening the panel Heat exchangerClean the Air Cleaning the air conditionerSlide it down Dry the Ai lter in a ventilated areaPeriodical checks Maintaining the air conditionerTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterIf may not be a Model Name Included Models Remark General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker Won’t be considered in-warranty and charged to end userModel Outdoor UnitTop view Side view When installing more than 1 outdoor unit When the air outlet is towards the wall Accessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsFix the indoor unit Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryThen pull it out through the appropriate hole Smooth the cut edgesCutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Connect the pipesCracked Correct InclinedApplying the following torque Outer DiameterChanging direction of the drain hose Drain hose installationExcessive torque can be cause of gas leakage Purging the connected pipesAdding Refrigerant Covered by the Kyoto Protocol 1975To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesFixing the outdoor unit in place Outdoor unit installed on the wall by rackPart without insulation on the end of the pipes Properly ModelPress the Power button and check the following Pump down procedure when removing the productPress the Mode button to select Cool or Heat mode Final Check and Trial OperationHow to connect your extended power cables Questions or COMMENTS?