Direction of pipe

Optional accessories

If using a multi system, refer to the manual supplied with the outdoor unit.

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated

Insulated Assembly

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

ENGLISH

Assembly Pipe,

Pipe, Ø9.52mm (1)

Ø12.70mm (1)

Ø15.88mm (1)

Insulation (1)

 

Ø6.35mm (1)

10

18

24

 

 

 

 

 

 

 

13

 

 

 

 

 

Drain Hose,

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Putty 100g (1)

 

length 2m (1)

 

 

 

 

Screws (6)

 

 

 

 

 

 

 

 

4-wire

3-wire

2-wire

3-wire

 

 

 

Assembly Cable (1)

Power Cable (1)

Assembly Cable (1) Assembly Cable (1)

 

 

 

10

18/24

18/24

18/24

 

 

 

13

 

 

 

 

 

 

• If these accessories are supplied, they will be in the accessory box.

• The wire assembly cable is optional. If it is not supplied, use the standard cable.

Tools required for installation

General Tools

• Vacuum Pump(Backward

prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

 

Drill

L Wrench

• Measuring Tape

Tools for test operations

• Thermometer

• Resistance Meter

• Electroscope

Fixing the installation plate

the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

Right (A)

 

 

Left (B)

A

B

Underside_right (C)

D

D

 

C

Rear_right or left (D)

 

 

 

1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

(Unit : mm) 10/13

 

Pipe hole

 

(Ø65mm)

 

27

27

120

68

(Unit : mm)

18/24

Pipe hole

 

(Ø65mm)

 

27

27

170

85

Make sure to drill only one hole after choosing the direction of the pipe.

27

Image 27
Contents Air Conditioner Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperaturePosition you prefer Using the Turbo functionPress the Air swing button on the remote controller Circulate the airMode Press the button Press the button to set the time Press the Set/Cancel button to active it onFrom the moment you have set the timer Using the Smart Saver functionTimer 1 hour Timer 5 hoursUsing the Quiet function Heat exchanger Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelDry the Ai lter in a ventilated area Cleaning the air conditionerClean the Air Slide it downPeriodical checks Maintaining the air conditionerTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter If may not be aConnection Model Name Included Models Remark General informationWon’t be considered in-warranty and charged to end user Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerModel Outdoor UnitWhen installing more than 1 outdoor unit  When the air outlet is towards the wallTop view Side view Accessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Connecting the cableFix the indoor unit Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryThen pull it out through the appropriate hole Smooth the cut edgesConnect the pipes Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Correct InclinedCracked Applying the following torqueChanging direction of the drain hose Drain hose installationExcessive torque can be cause of gas leakage Purging the connected pipesAdding Refrigerant Covered by the Kyoto Protocol 1975Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitProperly Model Outdoor unit installed on the wall by rackFixing the outdoor unit in place Part without insulation on the end of the pipesFinal Check and Trial Operation Pump down procedure when removing the productPress the Power button and check the following Press the Mode button to select Cool or Heat modeHow to connect your extended power cables Questions or COMMENTS?