Samsung ASV18PUQXXEA, ASV13PSPNXEA, ASV18PSPXXEA manual Checking before use, Operation ranges

Page 6

Checking before use

Operation ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the

Mode

Indoor

Outdoor

Indoor

Remark

temperature

temperature

humidity

 

 

 

 

 

Relative

 

Cooling

16˚C~32˚C

16˚C~46˚C

humidity

ASV10/13/18/24P 

 

 

 

80% or less

 

Dry

18˚C~32˚C

16˚C~46˚C

-

ASV10/13/18/24P 

 

 

 

 

 

If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.

Maintaining your air conditioner

Internal protections via the unit control system

This internal protection operates if an internal fault occurs in the air conditioner.

Type

Description

Against cold air

 

 

 

De-ice cycle

 

 

 

Protect compressor

The air conditioner does not start operating immediately to protect the compressor of the

outdoor unit after it has been started.

 

• If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures.

6

Image 6
Contents Air Conditioner Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesMain parts Power buttonChecking the name of the parts DisplayChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressCirculate the air Using the Turbo functionPress the Air swing button on the remote controller Position you preferMode Press the Set/Cancel button to active it on Press the button Press the button to set the timeTimer 5 hours Using the Smart Saver functionTimer 1 hour From the moment you have set the timerUsing the Quiet function Opening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerSlide it down Cleaning the air conditionerClean the Air Dry the Ai lter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter If may not be aConnection General information Model Name Included Models RemarkPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Won’t be considered in-warranty and charged to end userOutdoor Unit ModelWhen installing more than 1 outdoor unit  When the air outlet is towards the wallTop view Side view Accessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the assembly cable Connecting the cableFix the indoor unit Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Then pull it out through the appropriate holeUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Connect the pipesApplying the following torque Correct InclinedCracked Outer DiameterDrain hose installation Changing direction of the drain hosePurging the connected pipes Excessive torque can be cause of gas leakageAdding Refrigerant 1975 Covered by the Kyoto ProtocolTo check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesPart without insulation on the end of the pipes Outdoor unit installed on the wall by rackFixing the outdoor unit in place Properly ModelPress the Mode button to select Cool or Heat mode Pump down procedure when removing the productPress the Power button and check the following Final Check and Trial OperationHow to connect your extended power cables Questions or COMMENTS?