Remington QFP40 manual Venting

Page 39
SHINGLES OVERLAP
TOP EDGE OF
FLASHING FIG. 14
250-4721 JUNE 2001
(2) Step 6.
If an offset is necessary in the attic to avoid obstructions, it is important to sup- port the vent pipe every 3' (914mm) to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (page 38, Figure 11).
Whenever possible, use 45° elbows, instead of 90° elbows. The 45° elbow of- fers less restriction to the flow of flue gases and intake air.
Slip the flashing over the pipe section(s) protruding through the roof. Secure the base of the flashing to the roof with roofing nails. Insure the roofing material overlaps the top edge of the flashing as shown in Figure 14. Verify that the chimney is the required height above the roof. See “2-10-3 Vertical Termination Rule” on page 28 of this manual
NOTE:
(1)
Framing
FIG. 13
1 -1/2"Long
Wood Screws
Step 4. Assemble the desired lengths of GS pipe and elbows necessary to reach from the stove up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Be sure to seal the outer pipe with appropriate sealant (high temperature silicone).
Step 5. Cut a hole in the roof centered on the small drill hole placed in the roof in Step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof line. Galvanized pipe and elbows may be utilized in the attic, as well as above the roofline. The galvanized finish is desirable above the roofline, due to its higher corrosion resistance.
To install the round support box/wall thimble in a flat ceiling, cut a 10" (254mm) square hole in the ceiling, centered on the hole drilled in Step 2. Frame the hole
as shown in Figure 13.Ceiling Joists
Step 3.
REMINGTON QFP40 Direct Vent FIREPLACE
VERTICAL INSTALLATION INSTRUCTIONS

VENTING

Page 39

Image 39
Contents What to do if YOU Smell GAS For Your SafetyCongratulations WelcomeModel Name Serial Number Date Purchased Contents Operation Completing InstallationMaintenance Troubleshooting Parts & Accessories WarrantyRatings Plate Safety LabelModel Remington QFP40 Vented GAS Fireplace Heater STANDARDS/CLEARANCES LabelSafety Notices If YOU Smell GAS Safety NoticesHeating Specifications SpecificationsMinimum Cabinet Dimensions Preparation Installation TerminologyPreparation AN Overview Installation to OperationLP Conversion Instructions LP ConversionFIG. B Conversion INSTRUCTIONS,Minimum Framing Dimensions InstallationCorner Installations Raised Fireplace Raised Fireplace with Raised Hearth Hearth Requirements Combustible Mantels Mantel RequirementsAcid Wash Alert Fascia DimensionsInstallation Rectangular Fascia Facing RequirementsFacing Over 1 25mm Thick General Venting Instructions Installation PrecautionsSafety Precautions for the Installer VentingSimpson DURA-VENT Parts List Vertical Termination Rule Venting Installation Options & Guidelines#HHW2 OnlyInstallation Into a Class a Metal Chimney USA only Venting INSTALLATION,Installation Into a Masonry Chimney USA only HOW to USE Vent Graph Horizontal Termination Requirements Female Locking Lugs Male Locking Lugs Horizontal InstallationWall Wood Screw HHW2Siding Beneath Removed Venting Using GS Series Pipe Vertical Installation InstructionsVenting Minimum Clearance Cathedral Ceiling Installation Installation Into a Class a Metal Chimney USA only Installation Into AN Existing Masonry Chimney USA only Venting Venting GAS Line Requirements GAS LineElectrical Connection Copper White Wire BlackOptional Thermostat Installation ElectricalBrick Installation Brick InstallBrick INSTALLATION, Logset Install Logset and Nugget InstallationLOG Identification Nugget Placement Logset and Nugget INSTALLATION,Left Twig Fascia Installing GlassInstalling Fascia GlassLeak TEST/START-UP Leak TestInitial START-UP Normal Occurrences Lighting Instructions LightingAdjusting the Blower Speed AdjustmentsShutter Adjustment Damper AdjustmentHigh Altitude Operation Operation OperationControl Panel Maintenance MaintenanceYearly Servicing Procedures Glass Replacement Blower Replacement Electrical Schematic Troublshooting TroubleshootingTROUBLESHOOTING, Parts Parts & AccessoriesWarranty WarrantyDirect Vent Gas Fireplace