Remington QFP40 manual High Altitude Operation

Page 57

REMINGTON QFP40 Direct Vent FIREPLACE

HIGH ALTITUDE OPERATION

In Canada, this unit is approved from 0 to 4500 feet above sea level. Installation of this stove at altitudes above 4500 feet is subject to field test of the individual installation and approval by the local authority having jurisdiction.

In the United States, input ratings of this unit are based on sea level operation, and shall not be changed for operation at elevations up to 2000 feet. For operation at elevations above 2000 feet, this stove shall be reduced at the rate of 4% for each 1000 feet above sea level.

Exception: As permitted by the authority having jurisdiction.

To adjust stove for operation above 2000 feet the burner orifices may need to be changed. The orifices are located beneath the log set so it is necessary to first remove the logs. To do so please refer to the following detailed instructions to achieve optimum performance of your stove.

WARNING ! The following procedure should only be undertaken by a qualified and certified gas appliance installer.

CAUTION: DISCONNECT ANY ELECTRICAL CORDS AND TURN OFF GAS SUPPLY TO UNIT BEFORE PROCEEDING.

1.If logset is installed, remove logs and embers at this time.

2.With a Phillips screwdriver, remove pilot lighting channel and front log rack.

3.Remove the two Phillips head screws that secure the front and rear burner pan in place.

4.Remove the burner pans by sliding to the right and lifting out. (Shutters may need to be adjusted ‘closed’ to make this easier).

5.Slide shutters out of the way. Using a 3/8" wrench or socket, remove the orifice inserts and replace with proper orifices for the specified gas. See below.

6.Reinstall burner pans and adjust shutters to ‘open’ position.

CAUTION: The correct orifice placement is critical for proper appliance performance fol- low BTU de-rating chart below to locate the necessary orifice size for the front and rear burners.

EQUIVALENT ORIFICE SIZES AT HIGH ALTITUDES

(Includes 4% Input Reduction For Each 1000 Feet)

Orifice size

2000

3000

4000

5000

6000

7000

8000

9000 10000

 

at Sea Level:

 

 

 

 

 

 

 

 

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

Front

47

48

48

48

49

50

50

51

51

52

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear

42

43

43

43

44

44

45

46

47

47

 

 

 

 

 

 

 

 

 

 

 

 

Propane

 

 

 

 

 

 

 

 

 

 

Front

56

57

57

57

58

58

59

60

61

62

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear

53

54

54

54

54

54

55

55

55

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250-4721

JUNE 2001

 

 

 

 

 

 

 

 

 

ADJUSTMENTS

Page 57

Image 57
Contents What to do if YOU Smell GAS For Your SafetyCongratulations WelcomeModel Name Serial Number Date Purchased Contents Maintenance Completing InstallationTroubleshooting Parts & Accessories Warranty OperationRatings Plate Safety LabelModel Remington QFP40 Vented GAS Fireplace Heater STANDARDS/CLEARANCES LabelSafety Notices If YOU Smell GAS Safety NoticesHeating Specifications SpecificationsMinimum Cabinet Dimensions Preparation Installation TerminologyPreparation AN Overview Installation to OperationLP Conversion Instructions LP ConversionFIG. B Conversion INSTRUCTIONS,Minimum Framing Dimensions InstallationCorner Installations Raised Fireplace Raised Fireplace with Raised Hearth Hearth Requirements Combustible Mantels Mantel RequirementsAcid Wash Alert Fascia DimensionsInstallation Rectangular Fascia Facing RequirementsFacing Over 1 25mm Thick Safety Precautions for the Installer Installation PrecautionsVenting General Venting InstructionsSimpson DURA-VENT Parts List Vertical Termination Rule Venting Installation Options & Guidelines#HHW2 OnlyInstallation Into a Class a Metal Chimney USA only Venting INSTALLATION,Installation Into a Masonry Chimney USA only HOW to USE Vent Graph Horizontal Termination Requirements Female Locking Lugs Male Locking Lugs Horizontal InstallationWall Wood Screw HHW2Siding Beneath Removed Venting Using GS Series Pipe Vertical Installation InstructionsVenting Minimum Clearance Cathedral Ceiling Installation Installation Into a Class a Metal Chimney USA only Installation Into AN Existing Masonry Chimney USA only Venting Venting GAS Line Requirements GAS LineOptional Thermostat Installation Copper White Wire BlackElectrical Electrical ConnectionBrick Installation Brick InstallBrick INSTALLATION, Logset Install Logset and Nugget InstallationLOG Identification Nugget Placement Logset and Nugget INSTALLATION,Left Twig Installing Fascia Installing GlassGlass FasciaLeak TEST/START-UP Leak TestInitial START-UP Normal Occurrences Lighting Instructions LightingShutter Adjustment AdjustmentsDamper Adjustment Adjusting the Blower SpeedHigh Altitude Operation Operation OperationControl Panel Maintenance MaintenanceYearly Servicing Procedures Glass Replacement Blower Replacement Electrical Schematic Troublshooting TroubleshootingTROUBLESHOOTING, Parts Parts & AccessoriesWarranty WarrantyDirect Vent Gas Fireplace