LEAK TEST/START-UP
REMINGTON QFP40 Direct Vent FIREPLACE
LEAK TEST
1.Turn on gas to the fireplace.
2.Turn on gas at the manual shutoff valve.
3.Leak test all gas joints prior to starting the appliance.
4.Familiarize yourself with the control panel components, see page 58.
5.Follow Lighting Instructions on next page to light the pilot and then the main burner.
6.Leak test all gas joints again.
7.Check the pilot flame ensuring that it looks like the illustration below. Adjust the pilot flame if necessary.
Flames
Pilot Hood
Thermopile | Thermocouple |
Piezo Igniter
INITIAL START-UP: NORMAL OCCURRENCES
WARNING! You must clean all finger- prints and oils from any gold surface prior to firing the fireplace for the first
time.
Fumes from curing paint and oil burning off the steel is a normal occurrence. Open window to vent the area until fumes disappear.
Condensation appearing on the glass each time you start the fireplace is also normal. Blue Flames will occur on the initial
the yellow/orange flame color.
Remote Wall Switch: If you install a remote wall switch to operate the fireplace, leave the ON/OFF switch on the fireplace control panel in the “ON” position.
✔Do not place any combustible items on top of or directly in front of the fireplace, even temporarily. The optional thermostat may start the fireplace causing a combustible item to ignite.
✔If the fireplace turns on and off frequently while using the thermostat, you may want to adjust the flame height down until it produces just enough heat needed, or relocate the thermostat further away from the fireplace.
Page 54 |