REMINGTON QFP40 Direct Vent FIREPLACE

INSTALLING GLASS

The glass assembly has a narrow metal edge at top of the frame, and wide metal edge at bottom of the frame. To install the glass assembly, lift and set the bottom T-bar extensions onto the bottom alignment pins located at the edge of firebox--refer to diagram below. With the bottom edge of glass assembly resting on the bottom alignment pins, lift up and onto the top alignment pins. Secure the assembly to zc appliance with the spring latches, two on top and two at bottom.

Narrow Edge (TOP)

Spring Latches.

 

 

(2 upper & 2 lower)

Flanges for fas- cia attachment, and T-bar exten- sions for setting glass onto align- ment pins.

(2 per side)

T-bar extension

of Flange.Alignment pins. (2 per side)

GLASS &

Wide Edge (BOTTOM)

WARNING: Use care in handling of glass assembly, do not strike or slam as this could cause breakage.

INSTALLING FASCIA

All arched and rectangular fascia attach to four flanges located two to each side of the glass frame. Insert and finger start bolts tightening with the 5/32" Allen wrench supplied with unit.

Insert bolts through these holes and into Flanges shown in picture above. (2 per side)

FASCIA

250-4721 JUNE 2001

Page 53

Image 53
Contents What to do if YOU Smell GAS For Your SafetyCongratulations WelcomeModel Name Serial Number Date Purchased Contents Maintenance Completing InstallationTroubleshooting Parts & Accessories Warranty OperationRatings Plate Safety LabelModel Remington QFP40 Vented GAS Fireplace Heater STANDARDS/CLEARANCES LabelSafety Notices If YOU Smell GAS Safety NoticesHeating Specifications SpecificationsMinimum Cabinet Dimensions Preparation Installation TerminologyPreparation AN Overview Installation to OperationLP Conversion Instructions LP ConversionFIG. B Conversion INSTRUCTIONS,Minimum Framing Dimensions InstallationCorner Installations Raised Fireplace Raised Fireplace with Raised Hearth Hearth Requirements Combustible Mantels Mantel RequirementsAcid Wash Alert Fascia DimensionsInstallation Rectangular Fascia Facing RequirementsFacing Over 1 25mm Thick Safety Precautions for the Installer Installation PrecautionsVenting General Venting InstructionsSimpson DURA-VENT Parts List Vertical Termination Rule Venting Installation Options & Guidelines#HHW2 OnlyInstallation Into a Class a Metal Chimney USA only Venting INSTALLATION,Installation Into a Masonry Chimney USA only HOW to USE Vent Graph Horizontal Termination Requirements Female Locking Lugs Male Locking Lugs Horizontal InstallationWall Siding Beneath Removed Wood ScrewHHW2 Venting Using GS Series Pipe Vertical Installation InstructionsVenting Minimum Clearance Cathedral Ceiling Installation Installation Into a Class a Metal Chimney USA only Installation Into AN Existing Masonry Chimney USA only Venting Venting GAS Line Requirements GAS LineOptional Thermostat Installation Copper White Wire BlackElectrical Electrical ConnectionBrick Installation Brick InstallBrick INSTALLATION, LOG Identification Logset InstallLogset and Nugget Installation Nugget Placement Logset and Nugget INSTALLATION,Left Twig Installing Fascia Installing GlassGlass FasciaInitial START-UP Normal Occurrences Leak TEST/START-UPLeak Test Lighting Instructions LightingShutter Adjustment AdjustmentsDamper Adjustment Adjusting the Blower SpeedHigh Altitude Operation Control Panel OperationOperation Maintenance MaintenanceYearly Servicing Procedures Glass Replacement Blower Replacement Electrical Schematic Troublshooting TroubleshootingTROUBLESHOOTING, Parts Parts & AccessoriesWarranty WarrantyDirect Vent Gas Fireplace