Castile Pellet Insert
R
B. Clearance To Combustibles, UL and ULC | NOTE: All Clearances are Minimum Clearances |
AS A
A | C | D |
B |
| B |
C |
|
|
0 in. Clearance To Exposed Section And Face Trim |
Figure 10.1 | Must be installed in a | |||||
|
|
|
|
|
|
|
|
|
|
|
| Inches | Millimeters |
| A | Top of Hopper | Top Vent | 2.0 | 51 | |
|
|
|
| Rear Vent | 2.5 | 64 |
| B | Side of Hopper | Top or Rear Vent | 2.0 | 51 | |
| C | Back of Hopper | Top or Rear Vent | 4.0 | 102 | |
| D | Vent Pipe to Combustible | Top or Rear Vent | 3.0 | 76 |
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Outside Air
Combustible | 12 in |
|
Mantel |
| |
| (305mm) |
|
|
| 6 in |
| Top Vent: | (152mm) |
| 2 in. (51mm) |
|
| Rear Vent: |
|
| 2.5 in (64mm) |
|
| Back of Hopper: |
|
| 4 in (102mm) |
|
| Vent Pipe to | Outside Air |
| Combustibles: |
|
| 3 in (76mm) |
|
Figure 10.2
WARNING
Fire Risk.
Comply with all minimum clear- ances to combustibles as speci- fied.
Failure to comply may cause house fire.
NOTE:
•Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
•Illustrations/diagrams are not drawn to scale.
•Actual installation may vary due to individual design preference.
Page 10 | January 19, 2011 |