R

Castile Pellet Insert

E. Combustion Blower Replacement

1.If you have adequate clearance you will not have to remove the panel set and disconnect fl ue, if not then you will have to remove the panel set and disconnect the flue.

2.Pull appliance out onto the hearth.

3.Remove right cast side.

4.Disconnect the white and blue wires from the blower.

5.Remove blower mounting screws (not housing bolts), Figure 37.1, from blower housing and remove blower. The replacement blower is shipped with a housing. If you do not need the housing, discard it. If you do need to the replace the housing you will also need to replace the gasket. See Service Parts List for the part number.

6.Re-install in reverse order.

F.Convection Blower Replacement

1.The blower is located at the bottom rear of the insert. If an outside air kit is also installed, you will fi rst need to remove the outside air fl ange by removing the 2 screws using a Phillips head screwdriver. You do not need to remove the fl ex pipe from the fl ange.

2.If you have adequate clearance you will not have to remove the panel set and disconnect fl ue, if not then you will have to remove the panel set and disconnect the flue.

3.Pull appliance out onto the hearth.

4.Remove left cast side.

5.Disconnect the wires from the blower. The wires coming from the wiring harness are purple & white and the wires from the blower are black.

6.The blower is held in place with a wing screw.

7.Re-install in reverse order.

Housing Bolts

(Do Not Remove)

Blower

Screws

Figure 37.1

Wing Screw

Figure 37.2

January 19, 2011

7022-122

Page 37

Image 37
Contents Hot glass will cause burns Castile Pellet InsertWelcome to the Quadra-Fire Family Castile Pellet InsertTable of Contents Appliance Certification BTU & Efficiency Specifications Listing and Code ApprovalsMobile Home Approved Glass SpecificationsAppliance Location Getting StartedDraft Castile Pellet Insert Locating Your Appliance & ChimneyNegative Pressure Minimum Vacuum Requirements 095Castile Pellet Insert Avoiding Smoke and Odors Negative Pressure, Shut-Down and Electrical Power FailureVent Configurations Outside AirInspect Appliance & Components Castile Pellet Insert Fire SafetyTools And Supplies Needed Pre-Burn Check ListAppliance Dimensions 3Dimensions and ClearancesCastile Pellet Insert Clearance To Combustibles, UL and ULC Must be installed in a non-tapered enclosureShown with Rear Vent and Outside Air Minimum Opening for Masonry and Factory-Built Fireplaces Masonry and Factory-Built FireplacesCastile Pellet Insert Floor Protection Prefabricated Metal ChimneyAltering the Factory-Built Fireplace Using a saws-all, cut out the floorChimney and Exhaust Connection Vent InformationVenting Termination Requirements Minimum Vent for One Elbow Castile Pellet Insert Pellet Venting ChartsHorizontalHori tal Run,RunftFT MinimumVertical Vent for Three ElbowsFull Reline With Horizontal Outside Air 5Venting SystemsCastile Pellet Insert Full Reline With Vertical Outside Air 6Mobile Home Mobile Home InstallationOutside Air Kit Instructions 7Appliance Set-UpLeveling System Ance. Shown in Figures 18.1Castile Pellet Insert Door Handle Removal Adjustable Hearth SupportDoor Removal 20.7 Ex the sides into a bowed position before installing21.4 Surround & Trim Set, EconoSurround and Cast Trim Set Castile Pellet Insert Surround & Trim Set, Econo Cont’dPiece. Figure Shown in Figure .2 onTwo Piece Log Set Installation Castile Pellet Insert Thermostat Installation Combustible/Non-Combustible Materials Operating InstructionsFuel Material and Fuel Storage Before Your First Fire Castile Pellet Insert General Operating InformationClear Space Thermostat Calls For HeatFeed Rate Adjustment Instructions Fire CharacteristicsCastile Pellet Insert Starting Your First Fire Castile Pellet Insert Ignition Cycles Frequently Asked QuestionsTurn down thermostat and let the appliance completely cool Page Symptom Possible Cause Corrective Action Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartTypes of Fuel FrequencyCleaning Ash Drawer Cleaning Firepot with Cleaning Rod & Firepot Clean-Out ToolSee .1 on Ash Removal from Firebox Disposal of Ashes Frequency As neededCleaning Beneath Heat Exchanger Cleaning Heat Exchanger TubesCleaning the Glass Door Latch InspectionCleaning Exhaust Blower Requires No Lubrication Cleaning the HopperCleaning Convection Blower Requires No Lubrication Preparing Firebox for Non-Burn SeasonImmediate Attention and Cleaning is Required Castile Pellet Insert High Ash Fuel MaintenanceConvection Blower Replacement Castile Pellet Insert Combustion Blower ReplacementGlass Replacement Castile Pellet Insert Igniter ReplacementCastile Pellet Insert Baffle & Brick Set Removal Re-installing Baffle & Brick SetCastile Pellet Insert Re-installing Baffle & Brick Set Cont’d Component Function Reference MaterialsWiring Schematic See .1 below Vacuum SwitchThermostat Snap Disc #1 Convection Blower 110FCastile Pellet Insert Component Locations Cleaning Rods & Heat Exchanger TubesPart number list on following pages Service PartsCastile Pellet Insert Stocked At Depot#28 Feed Assembly #23 Door AssemblyStocked at Depot #38 Firepot and Associted Parts StockedOptional Accessories SP-CSTLI5134 Description Comments Part Number Fasteners Service And Maintenance Log Service And Maintenance Log Cont’d Homeowner’s Notes Limited Lifetime Warranty Warranty Conditions Contact Information