R
Castile Pellet Insert
E. Combustion Blower Replacement
1.If you have adequate clearance you will not have to remove the panel set and disconnect fl ue, if not then you will have to remove the panel set and disconnect the flue.
2.Pull appliance out onto the hearth.
3.Remove right cast side.
4.Disconnect the white and blue wires from the blower.
5.Remove blower mounting screws (not housing bolts), Figure 37.1, from blower housing and remove blower. The replacement blower is shipped with a housing. If you do not need the housing, discard it. If you do need to the replace the housing you will also need to replace the gasket. See Service Parts List for the part number.
6.
F.Convection Blower Replacement
1.The blower is located at the bottom rear of the insert. If an outside air kit is also installed, you will fi rst need to remove the outside air fl ange by removing the 2 screws using a Phillips head screwdriver. You do not need to remove the fl ex pipe from the fl ange.
2.If you have adequate clearance you will not have to remove the panel set and disconnect fl ue, if not then you will have to remove the panel set and disconnect the flue.
3.Pull appliance out onto the hearth.
4.Remove left cast side.
5.Disconnect the wires from the blower. The wires coming from the wiring harness are purple & white and the wires from the blower are black.
6.The blower is held in place with a wing screw.
7.
Housing Bolts |
(Do Not Remove) |
Blower |
Screws |
Figure 37.1
Wing Screw |
Figure 37.2
January 19, 2011 | Page 37 |