Quadra-Fire CASTILEI-MBK owner manual Limited Lifetime Warranty

Page 54

Castile Pellet Insert

Hearth & Home Technologies Inc.

LIMITED LIFETIME WARRANTY

R

Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.

WARRANTY COVERAGE:

HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo- nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.

WARRANTY PERIOD:

Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table.

The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.

Warranty Period

 

HHT Manufactured Appliances and Venting

Parts

Labor

Gas

Wood

Pellet

EPA

Coal

Electric

Venting

Wood

 

 

 

 

 

 

 

 

Components Covered

1 Year

X

X

X

X

X

X

X

All parts and material except as

covered by Conditions,

Exclusions, and Limitations

listed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

 

 

Igniters, electronic components,

 

 

2 years

 

 

 

 

and glass

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

X

X

 

 

Factory-installed blowers

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

Molded refractory panels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 years

 

 

X

 

 

 

 

Firepots and burnpots

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 years

1 year

 

 

X

X

 

 

 

Castings and baffles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 years

3 years

 

X

X

X

 

 

 

Manifold tubes,

 

 

 

 

 

 

HHT chimney and termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

1 year

X

 

 

 

 

 

 

Burners, logs and refractory

 

 

years

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limited

3 years

X

X

X

X

X

 

 

Firebox and heat exchanger

 

 

Lifetime

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 Days

X

X

X

X

X

X

X

All replacement parts

 

 

beyond warranty period

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See conditions, exclusions, and limitations on next page.

4021-645C 12-29-10

 

 

 

 

 

 

 

Page 1 of 2

Page 54

7022-122

January 19, 2011

Image 54
Contents Castile Pellet Insert Hot glass will cause burnsCastile Pellet Insert Welcome to the Quadra-Fire FamilyTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Glass SpecificationsGetting Started Appliance LocationNegative Pressure Castile Pellet Insert Locating Your Appliance & ChimneyDraft Minimum Vacuum Requirements 095Vent Configurations Negative Pressure, Shut-Down and Electrical Power FailureCastile Pellet Insert Avoiding Smoke and Odors Outside AirTools And Supplies Needed Castile Pellet Insert Fire SafetyInspect Appliance & Components Pre-Burn Check List3Dimensions and Clearances Appliance DimensionsMust be installed in a non-tapered enclosure Castile Pellet Insert Clearance To Combustibles, UL and ULCShown with Rear Vent and Outside Air Castile Pellet Insert Floor Protection Masonry and Factory-Built FireplacesMinimum Opening for Masonry and Factory-Built Fireplaces Prefabricated Metal ChimneyUsing a saws-all, cut out the floor Altering the Factory-Built FireplaceVent Information Chimney and Exhaust ConnectionVenting Termination Requirements HorizontalHori tal Run,RunftFT Castile Pellet Insert Pellet Venting ChartsMinimum Vent for One Elbow MinimumVertical Vent for Three Elbows5Venting Systems Full Reline With Horizontal Outside AirCastile Pellet Insert Full Reline With Vertical Outside Air Mobile Home Installation 6Mobile HomeLeveling System 7Appliance Set-UpOutside Air Kit Instructions Ance. Shown in Figures 18.1Adjustable Hearth Support Castile Pellet Insert Door Handle RemovalDoor Removal Ex the sides into a bowed position before installing 20.7Surround & Trim Set, Econo 21.4Piece. Figure Castile Pellet Insert Surround & Trim Set, Econo Cont’dSurround and Cast Trim Set Shown in Figure .2 onTwo Piece Log Set Installation Castile Pellet Insert Thermostat Installation Operating Instructions Combustible/Non-Combustible MaterialsFuel Material and Fuel Storage Clear Space Castile Pellet Insert General Operating InformationBefore Your First Fire Thermostat Calls For HeatFire Characteristics Feed Rate Adjustment InstructionsCastile Pellet Insert Starting Your First Fire Frequently Asked Questions Castile Pellet Insert Ignition CyclesTurn down thermostat and let the appliance completely cool Page Symptom Possible Cause Corrective Action Types of Fuel Quick Reference Maintenance ChartMaintaining & Servicing Your Appliance FrequencySee .1 on Ash Removal from Firebox Cleaning Firepot with Cleaning Rod & Firepot Clean-Out ToolCleaning Ash Drawer Disposal of Ashes Frequency As neededCleaning the Glass Cleaning Heat Exchanger TubesCleaning Beneath Heat Exchanger Door Latch InspectionCleaning Convection Blower Requires No Lubrication Cleaning the HopperCleaning Exhaust Blower Requires No Lubrication Preparing Firebox for Non-Burn SeasonCastile Pellet Insert High Ash Fuel Maintenance Immediate Attention and Cleaning is RequiredCastile Pellet Insert Combustion Blower Replacement Convection Blower ReplacementCastile Pellet Insert Igniter Replacement Glass ReplacementRe-installing Baffle & Brick Set Castile Pellet Insert Baffle & Brick Set RemovalCastile Pellet Insert Re-installing Baffle & Brick Set Cont’d Reference Materials Component FunctionThermostat Vacuum SwitchWiring Schematic See .1 below Snap Disc #1 Convection Blower 110FCleaning Rods & Heat Exchanger Tubes Castile Pellet Insert Component LocationsService Parts Part number list on following pagesCastile Pellet Insert At Depot Stocked#23 Door Assembly #28 Feed AssemblyStocked at Depot Stocked #38 Firepot and Associted PartsOptional Accessories SP-CSTLI5134 Description Comments Part Number Fasteners Service And Maintenance Log Service And Maintenance Log Cont’d Homeowner’s Notes Limited Lifetime Warranty Warranty Conditions Contact Information