5100-I ACT WOOD INSERT
Masonry Chimney (Cont’d)
R
The
NOTE: Installation into fireplaces without a permit will void the listing.
NOTE: In Canada, this fireplace insert must be installed with a continuous chimney liner of a 6 inch (152mm) diam- eter extending from the fireplace insert to the the top of the chimney. The chimney liner must conform to the Class 3 requirements of
UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System
Follow Manufacturer’s Instructions on Insulation and Support
For Zero or Other
Masonry Chimney Must
Have Structural Integrity
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Minimum 8 in. (203mm) Masonry
Thickness in Front of Smoke Chamber
Minimum Clearance in Accordance with Insert Listing
Floor Protection in
Accordance with Insert
Listing
Combustible Floor
Follow Manufacturer’s
Instructions for Maximum
Liner Extension Above
Chimney
Maximum 30 Degrees
Offset in Chimney
Damper Plate Removed or
Fastened in Open Position
Seal with
Figure 15.1