R

5100-I ACT WOOD INSERT

HOW TO ORDER

To order the entire assembly, order the top line part number only.

 

 

 

To order an individual part from an assembly, order the part(s)

 

 

 

 

 

 

listed in the indented portion.

 

 

 

 

 

 

 

 

Item

 

Description

 

Comments

Part Number

 

 

 

 

 

 

Stocked at Depot

 

Louver Assembly Only

Gold

438-5480

 

 

Nickel

438-5530

 

 

 

 

 

 

Black

430-3770

 

 

Louver, Single

Gold

430-3830

 

 

 

Nickel

430-5460

 

 

Nut, Keps Lock, 8-32

Qty: 40

226-0060/40

Y

 

Screw, Pan Head Philips 8-32 X

Qty: 40

225-0500/40

Y

 

3/8

 

 

 

 

 

Screw, Sheet Metal #8 X 1/2 S-

Qty: 40

12460/40

Y

 

Grip

 

 

 

 

 

Snap Disc, Ceramic

 

SRV230-0960

Y

 

Speed Control Only (Rheostat)

 

842-0370

Y

 

Wire Harness

 

832-3270

Y

13

Window Assembly, Side

Glass, Gold Trim & Frame

438-5440

 

Glass, Nickel Trim & Frame

438-5560

 

 

 

 

 

Bolt, Window Frame

Qty: 4

812-2350

 

 

Glass, Window

Qty: 1 pc, Lt/Rt Interchangeable

832-2000

Y

 

Nut, Keps Lock, 8-32

Qty: 40

226-0060/40

Y

 

Trim Ring, Window

Gold

430-2721

 

 

Nickel

430-5360

 

 

 

 

14

Blower, Rodale

Qty: 1 pc, Lt/Rt Interchangeable

832-3190

 

15

Mount, Blower, Right

 

SRV430-1194

 

16

Outside Air Cover Plate

 

430-2480

 

17

Flue Tab

 

438-0010

 

 

Component Pack (Includes Owners

For Gold Trim Units

438-5510

 

 

Manual, Warranty Card, Touch-Up

 

 

 

 

Paint, (1) Spring Handle 1/2”, (2)

 

 

 

 

1/4” Spring Handles, (2) Leveling

For Nickel Trim Units

438-5570

 

 

Bolts, 2 Consumer Cards, Epa &

 

 

 

 

 

 

Sales Efficiency Cards, “If Fireplace

 

 

 

 

Altered” Label)

 

 

 

 

 

 

 

 

 

Spring Handle, 1/2”

Gold

832-0620

Y

 

Nickel

250-8330

 

 

 

 

 

Spring Handle, 1/4”

Gold

832-0630

Y

 

Nickel

250-8340

 

 

 

 

 

Paint Touch-Up

 

7000-304

 

 

Door Handle Assembly

 

832-0540

Y

 

Rear Channel, Outside Air Kit

 

436-7020

 

 

Upgrade, Door, Nickel

Nickel Spring Handles, Hinge Pins &

UK-DRNL

 

 

Logo

 

 

 

 

 

Page 40

438-0380E

April 21, 2010

Image 40
Contents Advanced Combustion Technology ACT Hot glass will cause burnsLocation On right side of insert as face the appliance Serial NumberModel Name Manufactured DateTable of Contents Appliance Certification BTU & Efficiency Specifications Glass SpecificationsListing and Code Approvals Mobile Home ApprovedFire Safety Design, Installation & Location ConsiderationsGetting Started Asphyxiation RiskNegative Pressure Tools And Supplies Needed Flue Draft ConsiderationsInspect Appliance and Components Appliance Dimensions Dimensions and ClearancesPanel Size Clearance to Combustibles SideWallFloor Protection USA & Canada Calculating Alternate Floor Protection MaterialHearth Extension Insulation Alternatives, R Value = Hearth ExtensionPer Minimum Material Inch Thickness Required Installation Considerations Outside Air InstallationDisconnect the appliance from power supply Blower Cord LocationWiring Diagram Optional Offset AdapterChimney Requirements Venting SystemsInspections Larger ChimneysMasonry Chimney Cont’d Metal Heat Circulating Masonry Prefabricated Metal ChimneyPrefabricated Metal Chimney Cont’d Securing Chimney ComponentsAltering the Fireplace S629M, Standard for 650oC FACTORY-BUILT ChimneysOvalizing Round Stainless Steel Liners Air Clearances Chimney Height / Rise and RunChimney Termination Requirements RuleMobile Home Installation Fire Risk Asphyxiation RiskInstallation Outline Panel & Trim Set Installation Appliance Set-upLeveling Bolts Kit Includes Tools NeededSecuring Liner to Flue Collar Assembling TrimSize 12 d x 50 w, 2-10 h Zero Clearance Adjustable Trim SupportIncluded in Kit Tools Needed Operating Instructions Over-Firing Your ApplianceBurning Process Wood Selection & StorageSecond Stage Building a FireFinal Stage Opacity Burn Rates & Operating EfficiencyBTU / Hr Close Start-Up Air Primary Control Start-up Air System Air Controls Blower Operating InstructionsPrimary Air System Correct Baffle & Blanket Placement Incorrect PositionsFrequently Asked Questions Issues SolutionsGeneral Maintenance Creosote Chimney CleaningMaintaining & Servicing Your Appliance Disposal of AshesCleaning Plated Surfaces Glass CleaningWhen cleaning glass Baffle & Blanket Placement Quick Reference Maintenance GuideGlass Replacement Side Window Glass Replacement Door AssemblyFrequency As needed Door Handle Assembly Replacement Blower ReplacementFirebrick Replacement Nbr Brick Size QtyBaffle Removal Troubleshooting Start Fire Problems Possible Cause SolutionReference Materials Exploded DrawingsService Parts & Accessories Important this is Dated Information HOW to OrderHOW to Order Description Comments Part Number Stocked at DepotAt Depot StockedDescription Comments Part Number Warranty Policy April 21 438-0380E Do DIS N C OT AR D