Monessen Hearth CR, PF, CL)NVC/PVC, 624DV(ST manual Designer Series Direct Vent Gas Fireplace

Page 1

Designer Series Direct Vent Gas Fireplace

Model:

624dv(ST,PF,CR,CL)NVC/PVC,

NEC/PEC

WARNING

If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING: Improper installation, adjustment, alteration, services or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

Installation and Operating Instructions

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

CHILDRENANDADULTS SHOULD BEALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

Keep the room area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future refer- ence.

42D0200 2/10 Rev. 14

Image 1
Contents Designer Series Direct Vent Gas Fireplace Designer Series Gas Fireplaces Owner InstallerCode Approval Important Safety Information and code approvalPlease Read the Following Carefully Never connect unit to private nonHigh Elevations Product featuresFireplace Dimensions Fireplace Framing Peninsula & Corner Framing SpecificationsPeninsula Framing Framing Fireplace See-through Framing SpecificationsClearances to combustibles ClearancesMantel clearances Finishing MaterialFireplace location Installation and Operating InstructionsSecurE fireplace to floor InstallationOptional top vent application Optional TOP Vent installationInstallation precautions VentING installationVenting Clearances 42D0200 Canadian Installations1 US Installations2 VentING installationGeneral Venting Information Termination Location Dimensions How To Use The Vent GraphFeet Top View Flat Installation Rear Wall Vent installationInstalling Horizontal Vent Cap Adhered to Horizontal termination configurationsExample Horizontal termination configurationBelow Grade Installations Vertical through-the-roof applications Flat ceiling installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Installing gas piping to fireplace / burner system location Fireplace installationInstallation items needed Check gas typePropane/LP Natural GasLabel all wires before disconnecting when Electrical WiringServicing controls. Wiring errors can cause Remote Wall mounted Switch Electrical installationDo not connect wall switch to 110 V circuit Remote Wall Switch Electronic Pilot Ignition WiringOptional DC Remote Systems Glass Frame Removal Glass removalInstall logs and rock wool ember material in firebox LOG PlacementLog placement Install Top Log #6 Log placementVenting Height feet Grille Opening AIR Restrictor AdjustmentInitial lighting What to do if YOU Smell GASNever use an open flame to check for gas leak Never check for gas leak with open Approved leak testing methodFlame Lighting the burner Main burner switchPilot position Cleaning glass Cleaning and maintenanceFirebox cleaning Venting systemStanding Pilot Ignition TroubleshootingElectronic Ignition TroubleshootingYES Glass replacement and blower General troubleshootingOptional Blower accessory Blot Logs Replacement partsDescription Qty Natural Propane Replacement Parts are Available Through Your Retailer Fuel Conversion Kits Millivolt Natural Gas to LP Standing Pilot Millivolt ControlLP to Natural Gas Electronic Ignition Replacement PartsVent Components Replacement PartsDesigner Series Gas Fireplaces Designer Series Gas Fireplaces Designer Series Gas Fireplaces Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Fireplace Efficiency % Mhsc