fireplace installation | Designer Series Gas Fireplaces |
check gas type
Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit.
Installing gas piping to fireplace / burner system location
WARNING
A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
CAUTION
For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.
installation items needed
Before installing fireplace and burner system, make sure you have the items listed below.
• | External regulator | • | Piping (check local codes) | • | Sealant (resistant to propane/LP gas) |
| (supplied by installer) | • | Test gauge connection* | • | Sediment trap (recommended) |
• | Equipment shutoff valve* | • | Tee joint | • | Pipe wrench |
•approved flexible gas line with gas connector (if allowed by local codes — not provided)
*A CSA
For propane/LP connections the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 35. Pointing the vent down protects it from freezing rain or sleet.
| 100 gal. (min) | |
External | Propane/LP | |
Supply Tank | ||
Regulator | ||
| ||
| Vent Pointing | |
| Down | |
| FP1977 |
|
| Use only new black iron or steel pipe. Internally |
|
| tinned copper or copper tubing can be used |
| CAUTION | per National Fuel Code, Section 2.6.3, providing |
| gas meets hydrogen sulfide limits, and where | |
|
| |
|
| permitted by local codes. Gas piping system |
|
| must be sized to provide minimum inlet |
|
| pressure (listed on data plate) at the maximum |
|
| flow rate (BTU/hr). Undue pressure loss will |
|
| occur if the pipe is too small. |
|
|
|
When using copper of flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT.
Figure 35 -
External Regulator with Vent Pointing Down (Propane/LP Only)
42D0200 | 25 |