Monessen Hearth 624DV(ST, PF, CR, CL)NVC/PVC Lifetime Warranty, Five Year Warranty, Basic Warranty

Page 51

Designer Series Gas Fireplaces

Limited lifetime warranty policy

Lifetime Warranty

The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners.

Five Year Warranty

The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.

Basic Warranty

MHSC warrants the components and materials in your gas appliance to be free from manufacturing and material defects for a period of two years from date of installation. After installation, if any of the components manufactured by MHSC in the appliance are found to be defective in materials or workmanship, MHSC will, at its option, replace or repair the defective components at no charge to the original owner. MHSC will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase.

This Limited Lifetime Warranty will be void if the appliance in not installed by a qualified installer in accor- dance with the installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) firebox/burner assembly damage by accident, neglect, misuse, abuse, alterations, negligence of others, including the installation thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or (3) incidental or consequential damage. All service work must be performed by an authorized service representative.

This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchant- ability of fitness for purpose and of all other obligations or liabilities. MHSC does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. It states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also have additional rights not covered in the Limited Lifetime Warranty.

MHSC reserves the right to investigate any and all the claims against the Limited Lifetime Warranty and de- cide upon method of settlement.

IF WARRANTY SERVICE IS NEEDED...

1.Contact your supplier. Make sure you have your warranty, your sales receipt and the model/ serial number of your MHSC product.

2.DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.

42D0200

51

Image 51
Contents Designer Series Direct Vent Gas Fireplace Designer Series Gas Fireplaces Owner InstallerNever connect unit to private non Important Safety Information and code approvalCode Approval Please Read the Following CarefullyHigh Elevations Product featuresFireplace Dimensions Peninsula & Corner Framing Specifications Fireplace FramingPeninsula Framing Framing Fireplace See-through Framing SpecificationsFinishing Material ClearancesClearances to combustibles Mantel clearancesFireplace location Installation and Operating InstructionsSecurE fireplace to floor InstallationOptional top vent application Optional TOP Vent installationVentING installation Installation precautionsVenting Clearances 42D0200 VentING installation Canadian Installations1 US Installations2General Venting Information Termination Location How To Use The Vent Graph DimensionsFeet Top View Flat Installation Rear Wall Vent installationInstalling Horizontal Vent Cap Adhered to Horizontal termination configurationsExample Horizontal termination configurationBelow Grade Installations Vertical through-the-roof applications Flat ceiling installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Check gas type Fireplace installationInstalling gas piping to fireplace / burner system location Installation items neededPropane/LP Natural GasElectrical Wiring Label all wires before disconnecting whenServicing controls. Wiring errors can cause Electrical installation Remote Wall mounted SwitchDo not connect wall switch to 110 V circuit Electronic Pilot Ignition Wiring Remote Wall SwitchOptional DC Remote Systems Glass Frame Removal Glass removalInstall logs and rock wool ember material in firebox LOG PlacementLog placement Install Top Log #6 Log placementVenting Height feet Grille Opening AIR Restrictor AdjustmentWhat to do if YOU Smell GAS Initial lightingNever use an open flame to check for gas leak Approved leak testing method Never check for gas leak with openFlame Main burner switch Lighting the burnerPilot position Venting system Cleaning and maintenanceCleaning glass Firebox cleaningStanding Pilot Ignition TroubleshootingTroubleshooting Electronic IgnitionYES General troubleshooting Glass replacement and blowerOptional Blower accessory Blot Replacement parts LogsDescription Qty Natural Propane Replacement Parts are Available Through Your Retailer Standing Pilot Millivolt Control Fuel Conversion Kits Millivolt Natural Gas to LPLP to Natural Gas Electronic Ignition Replacement PartsVent Components Replacement PartsDesigner Series Gas Fireplaces Designer Series Gas Fireplaces Designer Series Gas Fireplaces Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Fireplace Efficiency % Mhsc