Monessen Hearth PF, CR, CL)NVC/PVC, 624DV(ST manual Troubleshooting, Electronic Ignition, Yes

Page 40

Designer Series Gas Fireplaces

troubleshooting

electronic Ignition

START

1.Turn gas supply off.

2.Turn ON/OFF switch to “ON” Power to module (24V Normal)

YES

Is there a spark across ignitor sensor gap?

YES

Turn on gas.

Does pilot burner light?

YES

Does spark stop when pilot is lit?

YES

Does main burner light?

YES

Does system run until ON/OFF switch is in “OFF” position?

YES

END OF TROUBLESHOOTING

 

 

 

Check: Line voltage (120VAC)

 

 

 

NO

Low voltage transformer (19.5 minimum VAC)

ON/OFF switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unplug ignition lead and

 

 

 

 

NO

check spark at module

 

 

 

 

(24VAC normal).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is spark OK?

 

NO

 

Replace module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yES

 

 

 

 

 

 

 

 

 

 

 

 

 

A.Check ignition cable ground wiring, ceramic insulator and gap. Correct if necessary.

B.Does ignition cable show signs of melting or buckling? Take protective action to shield cable and boot from excessive temperatures.

 

A. Are all manual gas valves open?

NO

Are supply tubing and pressure good?

Are pilot burner orifices blocked?

 

B.Check electrical connections between module and pilot operator on gas control.

C.Check for 24VAC across PV-MVPV terminals. If voltage is correct, replace gas control.

If voltage is not correct, replace module.

 

 

NOTE: If module goes into lockout, reset system.

NO

A. Check continuity of ignition cable and ground wire.

B. Clean flame rod.

 

 

 

 

C. Check electrical connections between flame rod and

 

 

module.

 

 

D. Is ceramic flame rod insulator cracked?

 

 

E. Is pilot flame a steady blue? Does flame cover flame rod?

 

 

If not, adjust pilot flame. Replace module if problem

 

 

persists.

 

 

 

A.Check for 24VAC across MV-MVPV terminal. Replace module if there is no voltage.

NO

B. Are electrical connections between module and gas

control good?

 

 

If connections are good, replace gas control or gas

 

control operator.

 

NOTE: If module goes into lockout, reset system.

 

 

A. Check continuity of ignition cable and ground wire.

NO

NOTE: If ground is poor or erratic, shutdown may

occasionally occur even though operation is normal

 

 

at time of checkout.

 

B.Is pilot flame a steady blue? Does flame cover flame rod? If above checks out, replace module.

40

42D0200

Image 40
Contents Designer Series Direct Vent Gas Fireplace Designer Series Gas Fireplaces Installer OwnerImportant Safety Information and code approval Code ApprovalPlease Read the Following Carefully Never connect unit to private nonProduct features High ElevationsFireplace Dimensions Fireplace Framing Peninsula & Corner Framing SpecificationsPeninsula Framing See-through Framing Specifications Framing FireplaceClearances Clearances to combustiblesMantel clearances Finishing MaterialInstallation and Operating Instructions Fireplace locationInstallation SecurE fireplace to floorOptional TOP Vent installation Optional top vent applicationInstallation precautions VentING installationVenting Clearances 42D0200 Canadian Installations1 US Installations2 VentING installationGeneral Venting Information Termination Location Dimensions How To Use The Vent GraphFeet Rear Wall Vent installation Top View Flat InstallationInstalling Horizontal Vent Cap Horizontal termination configurations Adhered toHorizontal termination configuration ExampleBelow Grade Installations Vertical through-the-roof applications Installation for vertical termination Flat ceiling installationConnect a section of pipe and extend up through the hole Fireplace installation Installing gas piping to fireplace / burner system locationInstallation items needed Check gas typeNatural Gas Propane/LPLabel all wires before disconnecting when Electrical WiringServicing controls. Wiring errors can cause Remote Wall mounted Switch Electrical installationDo not connect wall switch to 110 V circuit Remote Wall Switch Electronic Pilot Ignition WiringOptional DC Remote Systems Glass removal Glass Frame RemovalLOG Placement Install logs and rock wool ember material in fireboxLog placement Log placement Install Top Log #6AIR Restrictor Adjustment Venting Height feet Grille OpeningInitial lighting What to do if YOU Smell GASNever use an open flame to check for gas leak Never check for gas leak with open Approved leak testing methodFlame Lighting the burner Main burner switchPilot position Cleaning and maintenance Cleaning glassFirebox cleaning Venting systemTroubleshooting Standing Pilot IgnitionElectronic Ignition TroubleshootingYES Glass replacement and blower General troubleshootingOptional Blower accessory Blot Logs Replacement partsDescription Qty Natural Propane Replacement Parts are Available Through Your Retailer Fuel Conversion Kits Millivolt Natural Gas to LP Standing Pilot Millivolt ControlLP to Natural Gas Replacement Parts Electronic IgnitionReplacement Parts Vent ComponentsDesigner Series Gas Fireplaces Designer Series Gas Fireplaces Designer Series Gas Fireplaces Carbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %