Monessen Hearth PF, CR, CL)NVC/PVC, 624DV(ST Electrical installation, Remote Wall mounted Switch

Page 28

Designer Series Gas Fireplaces

Electrical installation

Remote Wall mounted Switch

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 38. Do not extend beyond the wall switch wire length provided.

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

OFF

PILOT

 

HI

 

ON

TH

 

 

 

 

TP

 

 

TH/TP

 

 

 

OPTIONAL REMOTE

 

 

 

WALL SWITCH

 

 

 

ON

ON

OFF

RS

OFF

 

 

 

 

 

 

 

 

OPTIONAL REMOTE

 

 

 

WALL SWITCH

 

 

 

ON

 

 

 

OFF

Figure 38 -

Wiring Diagram for Wall Switch

WARNING

Do not connect wall switch to (110 V) circuit.

28

42D0200

Image 28
Contents Designer Series Direct Vent Gas Fireplace Designer Series Gas Fireplaces Installer OwnerImportant Safety Information and code approval Code ApprovalPlease Read the Following Carefully Never connect unit to private nonProduct features High ElevationsFireplace Dimensions Fireplace Framing Peninsula & Corner Framing SpecificationsPeninsula Framing See-through Framing Specifications Framing FireplaceClearances Clearances to combustiblesMantel clearances Finishing MaterialInstallation and Operating Instructions Fireplace locationInstallation SecurE fireplace to floorOptional TOP Vent installation Optional top vent applicationInstallation precautions VentING installationVenting Clearances 42D0200 Canadian Installations1 US Installations2 VentING installationGeneral Venting Information Termination Location Dimensions How To Use The Vent GraphFeet Rear Wall Vent installation Top View Flat InstallationInstalling Horizontal Vent Cap Horizontal termination configurations Adhered toHorizontal termination configuration ExampleBelow Grade Installations Vertical through-the-roof applications Installation for vertical termination Flat ceiling installationConnect a section of pipe and extend up through the hole Fireplace installation Installing gas piping to fireplace / burner system locationInstallation items needed Check gas typeNatural Gas Propane/LPLabel all wires before disconnecting when Electrical WiringServicing controls. Wiring errors can cause Remote Wall mounted Switch Electrical installationDo not connect wall switch to 110 V circuit Remote Wall Switch Electronic Pilot Ignition WiringOptional DC Remote Systems Glass removal Glass Frame RemovalLOG Placement Install logs and rock wool ember material in fireboxLog placement Log placement Install Top Log #6AIR Restrictor Adjustment Venting Height feet Grille OpeningInitial lighting What to do if YOU Smell GASNever use an open flame to check for gas leak Never check for gas leak with open Approved leak testing methodFlame Lighting the burner Main burner switchPilot position Cleaning and maintenance Cleaning glassFirebox cleaning Venting systemTroubleshooting Standing Pilot IgnitionElectronic Ignition TroubleshootingYES Glass replacement and blower General troubleshootingOptional Blower accessory Blot Logs Replacement partsDescription Qty Natural Propane Replacement Parts are Available Through Your Retailer Fuel Conversion Kits Millivolt Natural Gas to LP Standing Pilot Millivolt ControlLP to Natural Gas Replacement Parts Electronic IgnitionReplacement Parts Vent ComponentsDesigner Series Gas Fireplaces Designer Series Gas Fireplaces Designer Series Gas Fireplaces Carbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %