troubleshooting | Designer Series Gas Fireplaces | |
General troubleshooting |
| |
SYMPTOM | POSSIBLE CAUSE | ACTION |
6. Glass Soots | A. Flame impingement |
| on logs |
A. Install log set per the instructions
Inspect the injector and air intake area. Make sure this area does not have any blockage from debris and clean.
Check gas supply.
7. Flame burn blue | A. Insufficient oxygen |
and lifts off burner | being supplied |
(ghosting) |
|
A.Ensure that the vent cap is installed properly and free of debris. Ensure that the vent system joints are tight and have no leaks. Ensure that no debris has been blocking the inner air intake at the bottom back of the combustion chamber. Ensure that the glass is properly secure and latch.
WARNING
Make sure the glass panel edges do not touch any metal parts during thermal expansion.
CAUTION
Glass replacement and blower
Always use gloves when handling broken glass.
•Never operate fireplace if glass is broken.
•Replace any glass that is chipped, cracked, or broken. Replacement glass assemblies MUST be supplied by fireplace manufacturer — No substitute materials may be used.
optional Blower accessory - BLOT
wiring diagram for Blower
Attach Blower to
Green Green
120 VAC | White |
Blower |
|
Black | Blower Plug |
120 VAC | Black Black |
| |
Speed Control |
|
ON/OFF Wall Switch or
Optional Variable Speed Switch
120 VAC
60Hz
Factory Supplied
Not Supplied
Junction Box
42D0200 | 41 |