INSTALLATION | Designer Series Gas Fireplaces |
| X |
|
|
| X | X |
|
| B |
|
|
A | Y | A | Y |
| Z |
| |
Y |
|
|
|
|
|
| FP2277 |
Figure 7 -
Possible Fireplace Locations
A.WALL LOCATION
Y Minimum distance between a glass panel and a parallel wall = 42"
Z Minimum distance between the edge of a glass panel and an adjacent wall = 3"
B.Island Location
X (Maximum length of horizontal venting = 20'. Refer to the venting section of this manual for specific dimensions.
AFlat on Wall B Room Divider
SecurE fireplace to floor
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 8. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets are adjustable from 1/2" to 5/8" to accommodate different thickness of noncombustible material.
Screws
Figure 8 -
Secure Fireplace to Floor and Framing Studs
FP2278