clearances | Designer Series Gas Fireplaces |
Clearances to combustibles
| Follow these instructions carefully to ensure safe installation. Failure |
WARNING | to follow instructions exactly can create a fire hazard. |
or noncombustible material panel extending full width and depth of | |
| The appliance cannot be installed on a carpet, tile or other |
| combustible material other than wood flooring. If installed on carpet |
| or vinyl flooring, the appliance shall be installed on a metal, wood |
| the appliance. |
|
|
mantel clearances
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
10” |
|
|
| 8” |
|
12” | 6” |
|
| 4” | |
| 10” | |
|
| |
| 8” | 2” |
|
| 6” |
|
| 4” |
Wall
Insulation Board
Standoff
Top of Louvers
Figure 6 -
Mantel Clearances
FP2279
WARNING
Never obstruct or modify the air inlet or outlet grills (louvers). This may create a fire hazard.
Finishing Material
NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to cover the
42D0200