Monessen Hearth KHLDV400, KHLDV500 operating instructions Installer, Owner

Page 3

IMPORTANT SAFETY INFORMATION

KHLDV Series Gas Fireplace

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

WARNING

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.

Any change to this fireplace or its controls can be dangerous.

Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning.

This fireplace is a vented product. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, combustion leakage can occur.

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, the fire- place may not have been installed properly. Get fresh air at once! Have the fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance prob- lems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply.

do not try to light any appliance.

do not touch any electrical switch; do not use any phone in your building .

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

73D0024

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace.

8.Turn fireplace off and let cool before servicing, install- ing, or repairing. Only a qualified service person should install, service, or repair the fireplace. Have burner system inspected annually by a qualified service person.

9.You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. Refer to Cleaning and Maintenance, Page 49.

11.Keep the area around your fireplace clear of combus- tible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decora- tions on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Never place anything on top of fireplace.

14.Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate.

Continued on page 4

Image 3
Contents Khldv Series Direct Vent Gas Fireplace Signature Command System Operation Instructions Operating Instructions Signature CommandOwner InstallerUtility gas wells. This gas is commonly Important Safety Information and Code ApprovalCode Approval Never connect unit to private nonGAS pressures Product featuresGas Specifications & Orifice Size High ElevationsKHLDV400 KHLDV500 Fireplace and Framing DimensionsCold Climate Insulation PRE-INSTALLATION InformationBefore You Start Firebox framingFireplace Location PRE-INSTALLATION InformationSide View ClearancesClearances to combustibles Mantel clearancesOver front face of fireplace Never install combustible materialsSECURe Fireplace to floor or framing Finishing MaterialLife Venting InstallationInstallation precautions Failure to follow these instructions will void WarrantyFor vertical termination Installation planningInstalling a vent system in an outside chase For horizontal terminationGeneral Venting Information Termination Location Canadian Installations1 US Installations2Outside Corner How To Use The Vent GraphVertical Sidewall Installation Always install horizontal venting on a level planeStep 610 mm Mm Max VERTICAL/Horizontal termination configurationsVentING installation Below Grade InstallationsTo be installed around the termination area Vertical through-the-roof applica- tions VentNG installationInstallation for vertical termina- tion Flat ceiling installationExample Termination Heights for Vents Above Flat or Sloped Roofs Fireplace installation Installing gas piping to fireplace / burner system locationCheck gas type Propane/LP Natural GasMillivolt Checking GAS Pressure and Electrical installation Optional Fan/Blower System Blotkhl Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Do not connect wall switch to a 110V circuitWA RNI GN Millivolt Optional FAN/BLOWER SystemBlower Access Covers Never use an open flame to check for gas leak Millivolt Operating InstructionsWhat to do if YOU Smell GAS Initial lightingNever check for gas leak with open flame Approved leak testing methodMain burner switch Lighting the burnerPilot position Or performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyDo not connect wall switch to 110 Junction BOX WiringCommand Center Wall Installation Wall Switch InstallationElectrical Installation Blotkhlsc Signature Command Blower Signature command Optional fan blower systemSignature command Operating Instructions OPERATing Instructions Command CenterFeatures Battery InstallationCommand Center System CONFIGURATION/SETUP Key Combinations for System SettingsFunction Operation Default Setting Command Center Operations Self Diagnostics ChartFunction Operation Turn appliance OFF at the Master Switch if Due to the sensitive temperature monitoringPerature before accurate room temperatures For accurate temperature readings to appear onResetting the transmitter Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Code setting, as they will communicate withTimer Mode Thermostat ModeSmart Mode Option for Thermostat Mode Figure Blower On Delay Time and Off Delay Time Setup Figure Blower Speed ControlLight Brightness Control Safety Features Setting up Blank Screen or Constant Display in IdleAUX Control Rear Burner On/Off Control Symptom Causes Action Using the Mounting BaseGlass Frame Removal Glass removalFinal installation BRICK, light bulb, and lens placementRock wool placement LOG placement Log placementPlace the upper right rear log over the rear log Burner, Pilot and Control Compart- ment Cleaning and maintenanceLogs Cleaning and maintenanceVent SysteM Glass DoorTroubleshooting Standing Pilot IgnitionPoSSIBLE Cause Troubleshooting Troubleshooting Signature Command SystemDescription Qty Replacement PartsFirebox components and accessories Accessories / Field Installed OptionsStanding Pilot Millivolt control Replacement PartsAccessories Fuel Conversion Kits Millivolt Control Natural Gas to LPLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Venting Components for 5x Current Old Simpson DuraventOr Mhsc Selkirk Box Description Manufacturer Requirements Requirements for the Commonwealth of MassachusettsLifetime Warranty Five Year WarrantyBasic Warranty Model EnerGuide Ratings Mhsc
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.