Monessen Hearth operating instructions Fireplace and Framing Dimensions, KHLDV400 KHLDV500

Page 6

KHLDV Series Gas Fireplace

FIREPLACE and FRAMING DIMENSIONS

 

 

 

Min. Rough

 

E

 

R

Opening

 

D

 

 

Depth

 

 

 

T

 

 

 

J

Q H

 

 

 

 

 

 

 

R

 

 

 

1/2” or 5/8”

 

 

P - Min. Rough Opening Width

 

 

 

S

Min. Rough

 

 

 

 

 

 

 

 

Opening

 

 

 

 

Height

 

 

 

 

 

K

 

 

 

O

 

 

 

 

I M

F

 

 

Figure 2 -

 

 

 

 

Fireplace and Framing Dimensions

 

 

 

 

 

 

L

C

 

 

 

B

N

 

 

 

A

 

Ref.

KHLDV400

 

KHLDV500

 

G

A

44ZB\zn"

(1141 mm)

48ZB\zn"

(1243 mm)

B

35Z\x"

(902 mm)

39Z\x"

(1003 mm)

C

32"

(813 mm)

36"

(914 mm)

D

22Z\x"

(572 mm)

24Z\x"

(622 mm)

E

28Z\,"

(714 mm)

32Z\,"

(816 mm)

F

30"

(762 mm)

30"

(762 mm)

G

38M\zn"

(976 mm)

38M\zn"

(976 mm)

H

23M\,"

(606 mm)

23M\,"

(606 mm)

I

44C\,"

(1127 mm)

44C\,"

(1127 mm)

J

8>\zn"

(218 mm)

8>\zn"

(218 mm)

K

4Z\v"

(108 mm)

4Z\v"

(108 mm)

L

4"

(102 mm)

4"

(102 mm)

M

38Z\zn"

(967 mm)

38Z\zn"

(967 mm)

N

1"

(25 mm)

1"

(25 mm)

 

Framing Dimensions

 

 

O

44C\v"

(1137 mm)

44C\v"

(1137 mm)

P

45B\zn"

(1153 mm)

49B\zn"

(1253 mm)

Q

23M\,"

(606 mm)

23M\,"

(606 mm)

R

53B\,"

(1362 mm)

56M\zn"

(1434 mm)

S

75M\,"

(1927 mm)

49M\,"

(2029 mm)

T

37ZB\zn"

(964 mm)

39ZB\zn"

(1014 mm)

73D0024

Image 6
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerNever connect unit to private non Important Safety Information and Code ApprovalCode Approval Utility gas wells. This gas is commonlyHigh Elevations Product featuresGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500Firebox framing PRE-INSTALLATION InformationBefore You Start Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationMantel clearances ClearancesClearances to combustibles Side ViewFinishing Material Never install combustible materialsSECURe Fireplace to floor or framing Over front face of fireplaceFailure to follow these instructions will void Warranty Venting InstallationInstallation precautions LifeFor horizontal termination Installation planningInstalling a vent system in an outside chase For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerVertical Sidewall Installation Always install horizontal venting on a level planeStep VERTICAL/Horizontal termination configurations 610 mm Mm MaxVentING installation Below Grade InstallationsTo be installed around the termination area VentNG installation Vertical through-the-roof applica- tionsInstallation for vertical termina- tion Flat ceiling installationExample Termination Heights for Vents Above Flat or Sloped Roofs Fireplace installation Installing gas piping to fireplace / burner system locationCheck gas type Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Do not connect wall switch to a 110V circuit Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Initial lighting Millivolt Operating InstructionsWhat to do if YOU Smell GAS Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flameMain burner switch Lighting the burnerPilot position Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsFeatures Battery InstallationCommand Center System CONFIGURATION/SETUP Key Combinations for System SettingsFunction Operation Default Setting Command Center Operations Self Diagnostics ChartFunction Operation For accurate temperature readings to appear on Due to the sensitive temperature monitoringPerature before accurate room temperatures Turn appliance OFF at the Master Switch ifCode setting, as they will communicate with Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Resetting the transmitterTimer Mode Thermostat ModeSmart Mode Option for Thermostat Mode Figure Blower On Delay Time and Off Delay Time Setup Figure Blower Speed ControlLight Brightness Control Safety Features Setting up Blank Screen or Constant Display in IdleAUX Control Rear Burner On/Off Control Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalFinal installation BRICK, light bulb, and lens placementRock wool placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentGlass Door Cleaning and maintenanceVent SysteM LogsTroubleshooting Standing Pilot IgnitionPoSSIBLE Cause Troubleshooting Signature Command System TroubleshootingAccessories / Field Installed Options Replacement PartsFirebox components and accessories Description QtyReplacement Parts Standing Pilot Millivolt controlAccessories Fuel Conversion Kits Millivolt Control Natural Gas to LPLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Venting Components for 5x Current Old Simpson DuraventOr Mhsc Selkirk Box Description Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsLifetime Warranty Five Year WarrantyBasic Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.