Monessen Hearth KHLDV500 Command Center Operations, Self Diagnostics Chart, Function Operation

Page 38

KHLDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

FUNCTIONS/OPERATION (with Command Center)

Turning on the fireplace

1.Turn on the master switch and wait for a beep.

2.Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set- ting or last memory setting (See Turning Off Fireplace below). For memory feature.

Pilot Safety Lockout Function

1.If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens. The LED on the Command Center flashes Green once every 2 seconds, until reset.

2.If the pilot flame is lost during normal operation, the system will try three (3) times to relight after three (3) failures, flame loss lockout happens. The LED on the Command Center flashes Red-Green once every 2 seconds, until re- set.

3.Turning the master switch on the Command Center to the off position, then ON again will reset the system.

Flame Height Control

1.Press the ON button (on the Command Center) once to turn on the main burner with maximum flame height.

2.Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium and low.

3.The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot will stay; in intermittent pilot configuration, the pilot will be shut off.

Turning the Fireplace Off

There are three ways to turn the fireplace off.

1.Flip the master switch to the off (“O”) position. (This will turn the entire system OFF.)

2.Press the OFF button to Medium, Low, then Off.

3.Hold the OFF button anytime for three seconds or by turning off the wall switch. These two commands of OFF are (Memory Off) the system will remember all last settings before turning off. The next time the fireplace is turned on, all settings will resume. To reset, change to the desired settings and shut off by using the Memory Off commands and the system will be reset to those new settings.

Command Center Operations:

The following functions are available on the Command Center.

Function

operation

 

Power Up

Flip the master switch to the ON ("_") position to power up the system

 

Fireplace ON

Press the ON button on the Command Center or turn on wall switch to turn the fireplace on

 

Fireplace OFF

Flip the master switch to the OFF ("o") position OR press the OFF button 3

 

 

times OR for Memory Off, hold the OFF button 3 seconds, or turn off wall switch

 

Flame Height Up

Press the ON button once to turn on the fireplace with maximum flame height

 

Flame Height Down

Press the OFF button to lower the flame height to Medium and Low

 

 

 

 

Self Diagnostics Chart:

The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a ser- vice call. Please refer to the charts below for indicator reference.

Fault

LED Indication

Conversion Cover Missing

One RED (1 time)

Spark Fail

Two RED (1 time)

No Sensor Signal

Three RED (1 time)

Pilot Lockout - trial

One GREEN, every 2 sec. (until manual reset)

Pilot Lockout - flame loss

One RED-GREEN, every 2 sec. (until manual reset)

Low Battery

One RED, every 10s (continuously)

No or Low Thermopile Power

Two RED, every 10s (continuously)

Learning

GREEN Flashes, every 1 sec. (for 10 sec.)

AC Power On

GREEN solid

Pressure Switch Failed (Power Vent only)

One RED every 2 sec. (until manual reset)

 

 

38

73D0024

Image 38
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerNever connect unit to private non Important Safety Information and Code ApprovalCode Approval Utility gas wells. This gas is commonlyHigh Elevations Product featuresGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500Firebox framing PRE-INSTALLATION InformationBefore You Start Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationMantel clearances ClearancesClearances to combustibles Side ViewFinishing Material Never install combustible materialsSECURe Fireplace to floor or framing Over front face of fireplaceFailure to follow these instructions will void Warranty Venting InstallationInstallation precautions LifeFor horizontal termination Installation planningInstalling a vent system in an outside chase For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerStep Vertical Sidewall InstallationAlways install horizontal venting on a level plane VERTICAL/Horizontal termination configurations 610 mm Mm MaxTo be installed around the termination area VentING installationBelow Grade Installations VentNG installation Vertical through-the-roof applica- tionsExample Installation for vertical termina- tionFlat ceiling installation Termination Heights for Vents Above Flat or Sloped Roofs Check gas type Fireplace installationInstalling gas piping to fireplace / burner system location Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Do not connect wall switch to a 110V circuit Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Initial lighting Millivolt Operating InstructionsWhat to do if YOU Smell GAS Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flamePilot position Main burner switchLighting the burner Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsCommand Center FeaturesBattery Installation Function Operation Default Setting System CONFIGURATION/SETUPKey Combinations for System Settings Function Operation Command Center OperationsSelf Diagnostics Chart For accurate temperature readings to appear on Due to the sensitive temperature monitoringPerature before accurate room temperatures Turn appliance OFF at the Master Switch ifCode setting, as they will communicate with Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Resetting the transmitterSmart Mode Option for Thermostat Mode Figure Timer ModeThermostat Mode Light Brightness Control Blower On Delay Time and Off Delay Time Setup FigureBlower Speed Control AUX Control Rear Burner On/Off Control Safety FeaturesSetting up Blank Screen or Constant Display in Idle Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalRock wool placement Final installationBRICK, light bulb, and lens placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentGlass Door Cleaning and maintenanceVent SysteM LogsPoSSIBLE Cause TroubleshootingStanding Pilot Ignition Troubleshooting Signature Command System TroubleshootingAccessories / Field Installed Options Replacement PartsFirebox components and accessories Description QtyReplacement Parts Standing Pilot Millivolt controlLP to Natural Gas AccessoriesFuel Conversion Kits Millivolt Control Natural Gas to LP Signature Command System KHLDV400 KHLDV500 Logs VENTing components Or Mhsc Selkirk Box Description Venting Components for 5xCurrent Old Simpson Duravent Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsBasic Warranty Lifetime WarrantyFive Year Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.