Monessen Hearth operating instructions KHLDV400 KHLDV500

Page 58
Kit #KHL400CKPS Kit #KHL500CKPS
Kit #KHL400CKNS Kit #KHL500CKNS

KHLDV Series Gas Fireplace

 

 

 

REPLACEMENT PARTS

 

 

 

 

 

SIGNATURE COMMAND SYSTEM

 

 

 

 

 

 

 

 

 

 

 

Item

Description

qty.

KHLDV400NTSC

KHLDV400PTSC

KHLDV500NTSC

KHLDV500PTSC

1.

Gas Valve Assembly

1

80D0001

80D0002

80D0001

80D0002

2.

Pilot Assembly

1

80D0039

80D0040

80D0039

80D0040

3.

Control Box

1

80D0037

80D0038

80D0037

80D0038

4.

Command Center

1

80D0005

80D0005

80D0005

80D0005

5a.

Tube, Rear, Venturi

1

73D349K

73D3549K

54D0564

54D0564

5b.

Tube, Front, Venturi

1

73D0562K

73D0562K

43D0185

43D1085

5c.

Rear Tube, Tee to Solenoid

1

73D3529K

73D3529K

73D3529K

73D3529K

5d.

Rear Tube, Solenoid to Venturi

1

73D3528K

73D3528K

73D3528K

73D3528K

5e.

Tube, Front, Through-wall

1

73D0146K

73D0146K

73D0146

73D0146

6.

Flexhose w/Shutoff Valve

1

69D0030

69D0030

69D0030

69D0030

7a.

Rear Injector

1

58D0102

58D0052

57D0679

57D0680

7b.

Front Injector

1

57D0612

58D0056

56D3059

62D3005

8a.

Rear Burner Assembly

1

73D3270

73D3270

73D3268

73D3268

8b.

Front Burner Assembly

1

73D3269

73D3269

73D3267

73D3267

9.

Venturi

1

45D0600

45D0600

45D0600

45D0600

10.

Wire Valve/Control (not shown)

1

80D0010

80D0010

80D0010

80D0010

11.

Wire AC Module (not shown)

1

80D0009

80D0009

80D0009

80D0009

12

Wire Command Ctr. (not shown)

1

80D0008

80D0008

80D0008

80D0008

13.

Remote Transmitter (full function)

1

TSFRSC

TSFRSC

TSFRSC

TSFRSC

14.

AC Module

1

SCSACM

SCSACM

SCSACM

SCSACM

15.

Solenoid (not shown)

1

73D3007

73D3007

73D3007

73D3007

 

Accessories

 

 

 

 

 

16.

Forged Andiron 13"

1

FA113

FA113

FA113

FA113

17.

Cast Iron 121/2"

1

CAI121/2

CAI121/2

CAI121/2

CAI121/2

18.

SCS Wall Extension Kit

1

SCSWEK

SCSWEK

SCSWEK

SCSWEK

 

(15' Wire, Rough-in Box, Wall Cover)

 

 

 

 

19.

Decorative Door Kit

1

KHL400ADBT

KHL400ADBT

KHL500ADBT

KHL500ADBT

Fuel Conversion Kits - Signature Command System

Natural Gas to LP

KHLDV400

KHLDV500

LP to Natural Gas

KHLDV400

KHLDV500

58

73D0024

Image 58
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerNever connect unit to private non Important Safety Information and Code ApprovalCode Approval Utility gas wells. This gas is commonlyHigh Elevations Product featuresGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500Firebox framing PRE-INSTALLATION InformationBefore You Start Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationMantel clearances ClearancesClearances to combustibles Side ViewFinishing Material Never install combustible materialsSECURe Fireplace to floor or framing Over front face of fireplaceFailure to follow these instructions will void Warranty Venting InstallationInstallation precautions LifeFor horizontal termination Installation planningInstalling a vent system in an outside chase For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerAlways install horizontal venting on a level plane Vertical Sidewall InstallationStep VERTICAL/Horizontal termination configurations 610 mm Mm MaxBelow Grade Installations VentING installationTo be installed around the termination area VentNG installation Vertical through-the-roof applica- tionsFlat ceiling installation Installation for vertical termina- tionExample Termination Heights for Vents Above Flat or Sloped Roofs Installing gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Do not connect wall switch to a 110V circuit Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Initial lighting Millivolt Operating InstructionsWhat to do if YOU Smell GAS Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flameLighting the burner Main burner switchPilot position Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Self Diagnostics Chart Command Center OperationsFunction Operation For accurate temperature readings to appear on Due to the sensitive temperature monitoringPerature before accurate room temperatures Turn appliance OFF at the Master Switch ifCode setting, as they will communicate with Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Resetting the transmitterThermostat Mode Timer ModeSmart Mode Option for Thermostat Mode Figure Blower Speed Control Blower On Delay Time and Off Delay Time Setup FigureLight Brightness Control Setting up Blank Screen or Constant Display in Idle Safety FeaturesAUX Control Rear Burner On/Off Control Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalBRICK, light bulb, and lens placement Final installationRock wool placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentGlass Door Cleaning and maintenanceVent SysteM LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause Troubleshooting Signature Command System TroubleshootingAccessories / Field Installed Options Replacement PartsFirebox components and accessories Description QtyReplacement Parts Standing Pilot Millivolt controlFuel Conversion Kits Millivolt Control Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Current Old Simpson Duravent Venting Components for 5xOr Mhsc Selkirk Box Description Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsFive Year Warranty Lifetime WarrantyBasic Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.