Monessen Hearth KHLDV500 Accessories, Fuel Conversion Kits Millivolt Control Natural Gas to LP

Page 56

KHLDV Series Gas Fireplace

 

 

 

REPLACEMENT PARTS

 

 

 

 

Standing Pilot – Millivolt Control

 

 

 

 

 

 

 

 

 

 

 

Item

Description

 

qty.

KHLDV400NV

KHLDV400PV

KHLDV500NV

KHLDV500PV

1.

Gas Valve Assembly

1

37D0117

37D0118

37D0117

37D0118

2.

Pilot Assembly

 

1

20H2048

20H2049

20H2048

20H2049

2C.

Replacement Thermocouple

1

37D1067

37D1067

37D1067

37D1067

2I.

Replacement Igniter w/wire

1

37D1069

37D1069

37D1069

37D1069

2T.

Replacement Thermopile

1

37D1068

37D1068

37D1068

37D1068

3.

Tube, Rear, Venturi

1

73D0050

74D0050

54D0564

54D0564

3.

Tube, Front, Venturi

1

73D0562

73D0562

43D0185

43D1085

3.

Tube, Rear,Through-wall

1

73D0145

73D0145

73D0145

73D0145

3.

Tube, Front, Through-wall

1

73D0146

73D0146

73D0146

73D0146

4.

Flexhose w/Shutoff Valve

1

69D0030

69D0030

69D0030

69D0030

5.

Rocker Switch

 

1

41D0048

41D0048

41D0048

41D0048

6.

Piezo Igniter

 

1

14D0503

14D0503

14D0503

14D0503

7.

Rear Injector

 

1

58D0102

58D0052

57D0679

57D0680

7.

Front Injector

 

1

57D0612

58D0056

56D3059

62D3005

8.

Rear Burner Assembly

1

73D3270

73D3270

73D2368

73D3268

8.

Front Burner Assembly

1

73D3269

73D3269

73D3267

73D3267

9.

Venturi

 

1

45D0600

45D0600

45D0600

45D0600

10.

Wire Assembly

 

1

44D0500

44D0500

44D0500

44D0500

10.

Wire Assembly

 

1

44D0501

44D0501

44D0501

44D0501

 

Accessories

 

 

 

 

 

 

11.

On/Off Remote Control

1

TSMT / RCB / RCBE / RCMT / WMTD

 

12.

Thermostatic Remote Control

1

TSST / RCST / RCT / RCSTE / RCSTEBA / RCSITEA / WWTD

13.

Wall Switch Kit

 

1

 

MVWS

 

14.

Wall Thermostat Kit

1

 

WT

 

 

15.

Forged Andiron 13"

1

 

FA113

 

15.

Cast Iron 121/2"

 

1

 

CAI121/2

 

Fuel Conversion Kits - Millivolt Control

 

 

 

 

Natural Gas to LP

 

 

 

 

 

 

 

KHLDV400

Kit #KHL400CKP

 

 

 

 

 

KHLDV500

Kit #KHL500CKP

 

 

 

 

LP to Natural Gas

 

 

 

 

 

 

 

KHLDV400

Kit #KHL400CKN

 

 

 

 

 

KHLDV500

Kit #KHL500CKN

 

 

 

 

56

73D0024

Image 56
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerImportant Safety Information and Code Approval Code ApprovalNever connect unit to private non Utility gas wells. This gas is commonlyProduct features Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500PRE-INSTALLATION Information Before You StartFirebox framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances Clearances to combustiblesMantel clearances Side ViewNever install combustible materials SECURe Fireplace to floor or framingFinishing Material Over front face of fireplaceVenting Installation Installation precautionsFailure to follow these instructions will void Warranty LifeInstallation planning Installing a vent system in an outside chaseFor horizontal termination For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerStep Vertical Sidewall InstallationAlways install horizontal venting on a level plane VERTICAL/Horizontal termination configurations 610 mm Mm MaxTo be installed around the termination area VentING installationBelow Grade Installations VentNG installation Vertical through-the-roof applica- tionsExample Installation for vertical termina- tionFlat ceiling installation Termination Heights for Vents Above Flat or Sloped Roofs Check gas type Fireplace installationInstalling gas piping to fireplace / burner system location Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Millivolt Remote Wall Switch Installation Remote Wall mounted SwitchDo not connect wall switch to a 110V circuit Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Millivolt Operating Instructions What to do if YOU Smell GASInitial lighting Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flamePilot position Main burner switchLighting the burner Optional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beJunction BOX Wiring Command Center Wall InstallationWall Switch Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsCommand Center FeaturesBattery Installation Function Operation Default Setting System CONFIGURATION/SETUPKey Combinations for System Settings Function Operation Command Center OperationsSelf Diagnostics Chart Due to the sensitive temperature monitoring Perature before accurate room temperaturesFor accurate temperature readings to appear on Turn appliance OFF at the Master Switch ifSetting Privacy Code on Transmitter Do not use two 2 or more remote control sysCode setting, as they will communicate with Resetting the transmitterSmart Mode Option for Thermostat Mode Figure Timer ModeThermostat Mode Light Brightness Control Blower On Delay Time and Off Delay Time Setup FigureBlower Speed Control AUX Control Rear Burner On/Off Control Safety FeaturesSetting up Blank Screen or Constant Display in Idle Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalRock wool placement Final installationBRICK, light bulb, and lens placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentCleaning and maintenance Vent SysteMGlass Door LogsPoSSIBLE Cause TroubleshootingStanding Pilot Ignition Troubleshooting Signature Command System TroubleshootingReplacement Parts Firebox components and accessoriesAccessories / Field Installed Options Description QtyReplacement Parts Standing Pilot Millivolt controlLP to Natural Gas AccessoriesFuel Conversion Kits Millivolt Control Natural Gas to LP Signature Command System KHLDV400 KHLDV500 Logs VENTing components Or Mhsc Selkirk Box Description Venting Components for 5xCurrent Old Simpson Duravent Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsBasic Warranty Lifetime WarrantyFive Year Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.