Monessen Hearth KHLDV500 Millivolt Remote Wall Switch Installation, Remote Wall mounted Switch

Page 24

KHLDV Series Gas Fireplace

Millivolt - REMOTE WALL SWITCH INSTALLATION

 

 

Remote Wall mounted Switch

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 31. Do not extend beyond the wall switch wire length provided.

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

OFF

PILOT

 

HI

 

ON

TH

 

 

 

 

TP

TH/TP

 

 

 

OPTIONAL REMOTE

 

 

 

WALL SWITCH

 

 

 

ON

ON

OFF

RS

OFF

 

 

 

 

 

WARNING

Do not connect wall switch to a 110V circuit.

Figure 31 -

Wiring Diagram for Wall Switch

CAUTION

Electrical connections should only be performed

service.

 

by a qualified, licensed electrician. Main power

 

supply must be turned off before connecting fans

 

to the main electrical power supply or performing

Optional Fan/Blower System (BLOTKHL)

important: Always check local building codes. This installation must comply with local regulations as well as the National Electric Code.

WIRING

1.Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60°C wire in accordance with prevailing codes.

2.Remove the external junction box cover by removing the screw from the right side of the outside firebox wall. Junction box was installed at the factory.

3.The junction box cover has a factory installed “romex” style strain relief connector. After connect- ing the wires, route the wire leads through this connector. Refer to the wiring diagram in Figure 33.

BEFORE INSTALLING BLOWER

1.Always turn off the gas supply and allow the unit to cool before proceeding.

2.Clean the inside of the firebox (wall and floor), where the blower and wires will be installed. Make sure the firebox wall and floor are clean and dry before mounting the blower.

WARNING

Before installing the blower, turn off the fireplace and allow to cool. Only a qualified service person should service and repair the fireplace. A qualified service person should connect and disconnect the fireplace to gas supply. Follow all local codes.

NOTE: It is very important to arrange the blower wires and wire assembly so that wires do not come in contact with blower blades or firebox.

INSTALLING BLOWERS

1.Remove screen rod assemblies by lifting rod and pushing back and down to release rod from the three hooks located behind the face of the fireplace on the right, left, and middle.

2.Remove the plate located in front of the glass at the bottom.

3.Rotate the access doors on the right and left side of the glass toward the glass.

4.Remove glass frame by releasing the three latches located at the top of the firebox. Tilt glass away from the unit, lift glass frame up and away from the unit. Page 45

5.Remove logs.

6.Remove hearth brick, wall brick and rear brick. NOTE: Remove brackets that secure wall brick.

24

73D0024

Image 24
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerImportant Safety Information and Code Approval Code ApprovalNever connect unit to private non Utility gas wells. This gas is commonlyProduct features Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500PRE-INSTALLATION Information Before You StartFirebox framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances Clearances to combustiblesMantel clearances Side ViewNever install combustible materials SECURe Fireplace to floor or framingFinishing Material Over front face of fireplaceVenting Installation Installation precautionsFailure to follow these instructions will void Warranty LifeInstallation planning Installing a vent system in an outside chaseFor horizontal termination For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerVertical Sidewall Installation Always install horizontal venting on a level planeStep VERTICAL/Horizontal termination configurations 610 mm Mm MaxVentING installation Below Grade InstallationsTo be installed around the termination area VentNG installation Vertical through-the-roof applica- tionsInstallation for vertical termina- tion Flat ceiling installationExample Termination Heights for Vents Above Flat or Sloped Roofs Fireplace installation Installing gas piping to fireplace / burner system locationCheck gas type Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Millivolt Remote Wall Switch Installation Remote Wall mounted SwitchDo not connect wall switch to a 110V circuit Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Millivolt Operating Instructions What to do if YOU Smell GASInitial lighting Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flameMain burner switch Lighting the burnerPilot position Optional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beJunction BOX Wiring Command Center Wall InstallationWall Switch Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsFeatures Battery InstallationCommand Center System CONFIGURATION/SETUP Key Combinations for System SettingsFunction Operation Default Setting Command Center Operations Self Diagnostics ChartFunction Operation Due to the sensitive temperature monitoring Perature before accurate room temperaturesFor accurate temperature readings to appear on Turn appliance OFF at the Master Switch ifSetting Privacy Code on Transmitter Do not use two 2 or more remote control sysCode setting, as they will communicate with Resetting the transmitterTimer Mode Thermostat ModeSmart Mode Option for Thermostat Mode Figure Blower On Delay Time and Off Delay Time Setup Figure Blower Speed ControlLight Brightness Control Safety Features Setting up Blank Screen or Constant Display in IdleAUX Control Rear Burner On/Off Control Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalFinal installation BRICK, light bulb, and lens placementRock wool placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentCleaning and maintenance Vent SysteMGlass Door LogsTroubleshooting Standing Pilot IgnitionPoSSIBLE Cause Troubleshooting Signature Command System TroubleshootingReplacement Parts Firebox components and accessoriesAccessories / Field Installed Options Description QtyReplacement Parts Standing Pilot Millivolt controlAccessories Fuel Conversion Kits Millivolt Control Natural Gas to LPLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Venting Components for 5x Current Old Simpson DuraventOr Mhsc Selkirk Box Description Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsLifetime Warranty Five Year WarrantyBasic Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.