Monessen Hearth KHLDV400 System CONFIGURATION/SETUP, Key Combinations for System Settings

Page 37

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

KHLDV Series Gas Fireplace

SYSTEM CONFIGURATION/SETUP

All System configuration/setup is done on the Command Center.

NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center.

Intermittent/Standing Pilot Setup (Default intermittent)

1.Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot.

2.After the above operation, one beep (for standing pilot) or two beeps (for intermittent pilot) will be given as confirmation.

Six-hour Safety Shutdown Option (Default ON)

1.The system comes preset from the factory with a six (6) hour shutdown from its last command of opera- tion. This is done to prevent the fireplace from continuing to operate if unattended. You may disable this feature if you wish.

NOTE: By disabling this feature, your fireplace may continue to operate unattended.

2.When the master switch is in the ON position (“-”), pressing the ON button and the OFF button on the Command Center simultaneously will toggle between enabling and disabling the six-hour shutdown op- tion.

3.After the above operation, one beep (for enabling the six-hour shutdown option) or two beeps (for disabling the six-hour shutdown option) will be given as confirmation.

Remote Transmitter Learn Function (Default OFF)

1.The RF receiver button located on the Control Board must be in the on position before the learn function can begin. Use paper clip to depress button. One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation. Refer to Figure 48 for location.

2.After the RF receiver is on, holding the OFF button on the Command Center while turning on the master switch will activate the learn function for the transmitter.

3.After the above operation, two beeps will be given and the green LED on the Command Center will flash for 10 seconds.

4.During the 10 seconds, press the OFF button on a transmitter to learn. Another two beeps will be given to confirm a successful learning. Refer to transmitter instructions for remote operations.

Shutting Off the Standing Pilot (Temporary Shut Off)

To shut off the standing pilot for service or summer shut down, press and hold the ON button on the Com- mand Center for 3 seconds when the master switch is in the ON position (“-”) and the main burner is off.

Note: Pilot will resume the next time system is turned on.

Key Combinations for System Settings

NOTE: When On/Off wall switch is used, it must be in the On position to perform all system setups.

Function

operation

Default Setting

Intermittent/Standing

Hold the ON button while turning on the master switch

Intermittent

Pilot Setup

(Beep once for standing pilot, twice for intermittent pilot)

Pilot

Standing Pilot Temp.

Hold the ON button 3 seconds (when the master switch

 

Shutoff

on the main burner is off)

 

RF Remote Receiver

Push the RF receiver On/Off button on the control board

RF OFF

On/Off

Beep once for ON and beep twice for OFF

 

Learn Remote

Hold the OFF button while turning on the master switch

 

Transmitter

(Beep twice then press any handheld remote button)

 

6-hour safety

Press the ON button and OFF button simultaneously

ON

shutdown setup

(Beep once for ON, twice for OFF)

 

 

 

 

73D0024

37

Image 37
Contents Khldv Series Direct Vent Gas Fireplace Signature Command System Operation Instructions Operating Instructions Signature CommandOwner InstallerCode Approval Important Safety Information and Code ApprovalNever connect unit to private non Utility gas wells. This gas is commonlyGas Specifications & Orifice Size Product featuresHigh Elevations GAS pressuresKHLDV400 KHLDV500 Fireplace and Framing DimensionsBefore You Start PRE-INSTALLATION InformationFirebox framing Cold Climate InsulationFireplace Location PRE-INSTALLATION InformationClearances to combustibles ClearancesMantel clearances Side ViewSECURe Fireplace to floor or framing Never install combustible materialsFinishing Material Over front face of fireplaceInstallation precautions Venting InstallationFailure to follow these instructions will void Warranty LifeInstalling a vent system in an outside chase Installation planningFor horizontal termination For vertical terminationGeneral Venting Information Termination Location Canadian Installations1 US Installations2Outside Corner How To Use The Vent GraphAlways install horizontal venting on a level plane Vertical Sidewall InstallationStep 610 mm Mm Max VERTICAL/Horizontal termination configurationsBelow Grade Installations VentING installationTo be installed around the termination area Vertical through-the-roof applica- tions VentNG installationFlat ceiling installation Installation for vertical termina- tionExample Termination Heights for Vents Above Flat or Sloped Roofs Installing gas piping to fireplace / burner system location Fireplace installationCheck gas type Propane/LP Natural GasMillivolt Checking GAS Pressure and Electrical installation Remote Wall mounted Switch Millivolt Remote Wall Switch InstallationDo not connect wall switch to a 110V circuit Optional Fan/Blower System BlotkhlWA RNI GN Millivolt Optional FAN/BLOWER SystemBlower Access Covers What to do if YOU Smell GAS Millivolt Operating InstructionsInitial lighting Never use an open flame to check for gas leakNever check for gas leak with open flame Approved leak testing methodLighting the burner Main burner switchPilot position Electrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beCommand Center Wall Installation Junction BOX WiringWall Switch Installation Do not connect wall switch to 110Electrical Installation Blotkhlsc Signature Command Blower Signature command Optional fan blower systemSignature command Operating Instructions OPERATing Instructions Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Self Diagnostics Chart Command Center OperationsFunction Operation Perature before accurate room temperatures Due to the sensitive temperature monitoringFor accurate temperature readings to appear on Turn appliance OFF at the Master Switch ifDo not use two 2 or more remote control sys Setting Privacy Code on TransmitterCode setting, as they will communicate with Resetting the transmitterThermostat Mode Timer ModeSmart Mode Option for Thermostat Mode Figure Blower Speed Control Blower On Delay Time and Off Delay Time Setup FigureLight Brightness Control Setting up Blank Screen or Constant Display in Idle Safety FeaturesAUX Control Rear Burner On/Off Control Symptom Causes Action Using the Mounting BaseGlass Frame Removal Glass removalBRICK, light bulb, and lens placement Final installationRock wool placement LOG placement Log placementPlace the upper right rear log over the rear log Burner, Pilot and Control Compart- ment Cleaning and maintenanceVent SysteM Cleaning and maintenanceGlass Door LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause Troubleshooting Troubleshooting Signature Command SystemFirebox components and accessories Replacement PartsAccessories / Field Installed Options Description QtyStanding Pilot Millivolt control Replacement PartsFuel Conversion Kits Millivolt Control Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Current Old Simpson Duravent Venting Components for 5xOr Mhsc Selkirk Box Description Manufacturer Requirements Requirements for the Commonwealth of MassachusettsFive Year Warranty Lifetime WarrantyBasic Warranty Model EnerGuide Ratings Mhsc
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.