Monessen Hearth KHLDV400 Due to the sensitive temperature monitoring, LCD display, Logo Bar

Page 39

TOUCH SCREEN REMOTE CONTROL OPERATION

KHLDV Series Gas Fireplace

 

 

Due to the sensitive temperature monitoring

 

 

components in the transmitter, it is necessary

 

NOTE

to allow the transmitter to stabilize to room tem-

 

perature before accurate room temperatures

 

 

 

 

are displayed. If the transmitter is activated

 

 

from a severe cold condition, allow 15 minutes

 

 

for accurate temperature readings to appear on

 

 

the LCD display.

 

 

 

 

 

 

 

WARNING

Turn appliance OFF (at the Master Switch) if

 

you are away from your house for an extended

 

 

 

 

period of time. Never leave anything on top of

 

 

the surface of the transmitter.

 

 

 

nFunction Areas of the LCD Display

Figure 26 shows the display of the TSFRSC LCD.

Information Bar

The information bar shows the room temperature, the “sending signal” radio icon, the low battery indication icon,

Information Bar

 

 

Menus

Touch Area

Adjustment Controls

Logo Bar

 

 

Function Areas of the LCD Display

Logo Bar

Figure 49

The Logo Bar contains the brand logo: Signature Com- mand System.

the child-proof icon, and the flame icon. This area doesn’t have touch buttons.

The room temperature will always be shown after power-up. It displays the room temperature from 40 °F to 99 °F. “Lo” and “HI” will be displayed when the room temperature is lower than 40°F or higher than 99°F, respectively.

The radio icon will be shown when the transmitter is sending a signal.

The low battery indication icon will be shown when the battery voltage is low.

The child-proof icon will be shown when the child- proof mode is activated.

The flame icon indicates the current flame height - Off, Low, Medium and High

nInitialization and Setting up

Installing Batteries:

Figure 50

The remote transmitter has two battery compartments, one on each end of the trans- mitter. Always change all four (4) batteries at the same time.

To install batteries,

1.Press down the battery door tab and pull out to re- move the battery door.

2.Install the batteries as in- dicated inside the battery compartments.

Battery Door Tabs

Figure 50

Touch Area

The touch area contains all touch buttons to control the transmitter. It consists of two categories: menus and ad- justment arrows. The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed.

The menus include TIMER, THERMO, LIGHT, FAN and AUX (Rear Burner Control).

The adjustment arrows include ON/up and OFF/ down. Their default function is to adjust the flame height. When a button from the menu is pressed, the ON/up and OFF/down buttons will temporarily become adjustment controls for the selected item. When the adjustment is done, the ON/up and OFF/ down buttons go back to flame height controller again.

3.Close the battery door by snapping in place.

4.When all four batteries are installed, the transmitter will initialize for 5 seconds and then is ready for use.

5.The batteries should be replaced every 12 months or when the low battery icon indicator is displayed.

Changing Temperature Unit

When batteries are installed in the transmitter,

1.All available icons on the LCD will be turned on then be cleared.

2.The LCD will display temperature unit: °F. Use ON ∆ to toggle the units between °F and °C within the first 5 seconds.

3.The transmitter enters Manual Mode

4.The LCD displays room temperature with the chosen unit.

73D0024

39

Image 39
Contents Khldv Series Direct Vent Gas Fireplace Signature Command System Operation Instructions Operating Instructions Signature CommandOwner InstallerUtility gas wells. This gas is commonly Important Safety Information and Code ApprovalCode Approval Never connect unit to private nonGAS pressures Product featuresGas Specifications & Orifice Size High ElevationsKHLDV400 KHLDV500 Fireplace and Framing DimensionsCold Climate Insulation PRE-INSTALLATION InformationBefore You Start Firebox framingFireplace Location PRE-INSTALLATION InformationSide View ClearancesClearances to combustibles Mantel clearancesOver front face of fireplace Never install combustible materialsSECURe Fireplace to floor or framing Finishing MaterialLife Venting InstallationInstallation precautions Failure to follow these instructions will void WarrantyFor vertical termination Installation planningInstalling a vent system in an outside chase For horizontal terminationGeneral Venting Information Termination Location Canadian Installations1 US Installations2Outside Corner How To Use The Vent GraphVertical Sidewall Installation Always install horizontal venting on a level planeStep 610 mm Mm Max VERTICAL/Horizontal termination configurationsVentING installation Below Grade InstallationsTo be installed around the termination area Vertical through-the-roof applica- tions VentNG installationInstallation for vertical termina- tion Flat ceiling installationExample Termination Heights for Vents Above Flat or Sloped Roofs Fireplace installation Installing gas piping to fireplace / burner system locationCheck gas type Propane/LP Natural GasMillivolt Checking GAS Pressure and Electrical installation Optional Fan/Blower System Blotkhl Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Do not connect wall switch to a 110V circuitWA RNI GN Millivolt Optional FAN/BLOWER SystemBlower Access Covers Never use an open flame to check for gas leak Millivolt Operating InstructionsWhat to do if YOU Smell GAS Initial lightingNever check for gas leak with open flame Approved leak testing methodMain burner switch Lighting the burnerPilot position Or performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyDo not connect wall switch to 110 Junction BOX WiringCommand Center Wall Installation Wall Switch InstallationElectrical Installation Blotkhlsc Signature Command Blower Signature command Optional fan blower systemSignature command Operating Instructions OPERATing Instructions Command CenterFeatures Battery InstallationCommand Center System CONFIGURATION/SETUP Key Combinations for System SettingsFunction Operation Default Setting Command Center Operations Self Diagnostics ChartFunction Operation Turn appliance OFF at the Master Switch if Due to the sensitive temperature monitoringPerature before accurate room temperatures For accurate temperature readings to appear onResetting the transmitter Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Code setting, as they will communicate withTimer Mode Thermostat ModeSmart Mode Option for Thermostat Mode Figure Blower On Delay Time and Off Delay Time Setup Figure Blower Speed ControlLight Brightness Control Safety Features Setting up Blank Screen or Constant Display in IdleAUX Control Rear Burner On/Off Control Symptom Causes Action Using the Mounting BaseGlass Frame Removal Glass removalFinal installation BRICK, light bulb, and lens placementRock wool placement LOG placement Log placementPlace the upper right rear log over the rear log Burner, Pilot and Control Compart- ment Cleaning and maintenanceLogs Cleaning and maintenanceVent SysteM Glass DoorTroubleshooting Standing Pilot IgnitionPoSSIBLE Cause Troubleshooting Troubleshooting Signature Command SystemDescription Qty Replacement PartsFirebox components and accessories Accessories / Field Installed OptionsStanding Pilot Millivolt control Replacement PartsAccessories Fuel Conversion Kits Millivolt Control Natural Gas to LPLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Venting Components for 5x Current Old Simpson DuraventOr Mhsc Selkirk Box Description Manufacturer Requirements Requirements for the Commonwealth of MassachusettsLifetime Warranty Five Year WarrantyBasic Warranty Model EnerGuide Ratings Mhsc
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.