Monessen Hearth KHLDV500 Signature command Operating Instructions, What to do if YOU Smell GAS

Page 34

KHLDV Series Gas Fireplace

signature command - OPERATING INSTRUCTIONS

 

 

for your safety read before lighting

WARNING

If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not attempt to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your finger to push in the master switch. Never use tools. If the switch will not function by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

continued on next page

34

73D0024

Image 34
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerNever connect unit to private non Important Safety Information and Code ApprovalCode Approval Utility gas wells. This gas is commonlyHigh Elevations Product featuresGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500Firebox framing PRE-INSTALLATION InformationBefore You Start Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationMantel clearances ClearancesClearances to combustibles Side ViewFinishing Material Never install combustible materialsSECURe Fireplace to floor or framing Over front face of fireplaceFailure to follow these instructions will void Warranty Venting InstallationInstallation precautions LifeFor horizontal termination Installation planningInstalling a vent system in an outside chase For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerAlways install horizontal venting on a level plane Vertical Sidewall InstallationStep VERTICAL/Horizontal termination configurations 610 mm Mm MaxBelow Grade Installations VentING installationTo be installed around the termination area VentNG installation Vertical through-the-roof applica- tionsFlat ceiling installation Installation for vertical termina- tionExample Termination Heights for Vents Above Flat or Sloped Roofs Installing gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Do not connect wall switch to a 110V circuit Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Initial lighting Millivolt Operating InstructionsWhat to do if YOU Smell GAS Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flameLighting the burner Main burner switchPilot position Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Self Diagnostics Chart Command Center OperationsFunction Operation For accurate temperature readings to appear on Due to the sensitive temperature monitoringPerature before accurate room temperatures Turn appliance OFF at the Master Switch ifCode setting, as they will communicate with Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Resetting the transmitterThermostat Mode Timer ModeSmart Mode Option for Thermostat Mode Figure Blower Speed Control Blower On Delay Time and Off Delay Time Setup FigureLight Brightness Control Setting up Blank Screen or Constant Display in Idle Safety FeaturesAUX Control Rear Burner On/Off Control Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalBRICK, light bulb, and lens placement Final installationRock wool placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentGlass Door Cleaning and maintenanceVent SysteM LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause Troubleshooting Signature Command System TroubleshootingAccessories / Field Installed Options Replacement PartsFirebox components and accessories Description QtyReplacement Parts Standing Pilot Millivolt controlFuel Conversion Kits Millivolt Control Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Current Old Simpson Duravent Venting Components for 5xOr Mhsc Selkirk Box Description Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsFive Year Warranty Lifetime WarrantyBasic Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.