Monessen Hearth KHLDV500 Setting Privacy Code on Transmitter, Performing Learn Function, General

Page 40
Figure 51

KHLDV Series Gas Fireplace

TOUCH SCREEN REMOTE CONTROL OPERATION

Setting Privacy Code on Transmitter:

Figure 51

The remote transmitter privacy code is preset in facto- ry. In the event of activation or interference from other nearby transmissions, change the

code using the following procedures (learn function must be performed after changing the code):

1.Press the ON/arrow button and the TIMER button at the same time to enter privacy code setup mode.

2.The setup display is shown in the figure. The four digits on the top stand for the privacy code (as the actual DIP switches on Ambient’s

previous remotes). The default

values of the four digits will be all “1” (ON).

3.The first digit will be flashing upon entering the setup mode. Push the ON button to toggle its value between “0” (OFF) and “1”(ON), and push the “OFF” button to jump to the next digit. The next digit will then start flashing and the first one stops flashing. Set up the four digits to your choice.

4.After setting up all the four digits, push “OFF” to finish the process and return to the previous mode.

5.The Signature Command control board then needs to re-learn the new setting.

Performing Learn Function

1.The RF receiver button on the control board in the fire- place must be in the on position before the learn func- tion can begin. Figure 52. With the Command Center master switch in the ON position, use paper clip to de- press the recessed button on Control Board, one beep for RF receiver ON or two beeps for RF receiver OFF.

Battery Door

FP2650

Master Switch

ON

LED

OFFFigure 53

Command Center

transmitter to learn. Another two beeps will be given to confirm a successful learning. Figure 30

 

WARNING

Do not use two (2) or more remote control sys-

 

tems in the same area with the same privacy

 

 

 

 

code setting, as they will communicate with

 

 

each other. This may cause the appliances to

 

 

malfunction.

 

 

 

Resetting the transmitter:

If the transmitter is not working properly, reinstall the bat- teries to reset the transmitter.

1.Pull out at least one of the batteries.

2.Press any key on the screen to discharge.

3.Wait for 10 seconds and reinstall the batteries.

Pushing and holding any key for more than 10 seconds until the display refreshes will also reset the transmitter.

nFunctions and Operations

General:

The TSFRSC Remote Control has four (4) operating modes: Manual, Timer, Thermostatic and Smart Mode.

2.Holding the OFF button on the Com- mand Center while turning on the master switch will activate the learn function for the transmitter.

3.After the above op- eration, two beeps will be given and the green LED on the Command Cen- ter will flash for 10 seconds.

RF Receiver

ON/OFF

Control Board

The control system can be set to temperature range between 45° F and 90° F. The blower speed and flame height can be adjusted in the manual, timer and thermo- static mode. The Smart Mode will automatically adjust flame height and blower speed according to the differ- ence between Set and Room temperatures.

The transmitter will operate the remote receiver from 1 foot to a maximum of 30 feet. The distance is reduced when batteries are low.

Manual Mode

Figure 54

In this mode, the TIMER button and the THERMO but- ton will only display “TIMER” and “THERMO”, respec- tively without showing the time and the SET temperature.

Figure 52

4. During the 10 seconds, press the OFF button on the

Pressing the ON/up and OFF/down buttons will change the flame height if none of the menu buttons (TIMER, THERMO, LIGHT, FAN, AUX) are pressed and flashing.

40

73D0024

Image 40
Contents Khldv Series Direct Vent Gas Fireplace Operating Instructions Signature Command Signature Command System Operation InstructionsInstaller OwnerImportant Safety Information and Code Approval Code ApprovalNever connect unit to private non Utility gas wells. This gas is commonlyProduct features Gas Specifications & Orifice SizeHigh Elevations GAS pressuresFireplace and Framing Dimensions KHLDV400 KHLDV500PRE-INSTALLATION Information Before You StartFirebox framing Cold Climate InsulationPRE-INSTALLATION Information Fireplace LocationClearances Clearances to combustiblesMantel clearances Side ViewNever install combustible materials SECURe Fireplace to floor or framingFinishing Material Over front face of fireplaceVenting Installation Installation precautionsFailure to follow these instructions will void Warranty LifeInstallation planning Installing a vent system in an outside chaseFor horizontal termination For vertical terminationCanadian Installations1 US Installations2 General Venting Information Termination LocationHow To Use The Vent Graph Outside CornerAlways install horizontal venting on a level plane Vertical Sidewall InstallationStep VERTICAL/Horizontal termination configurations 610 mm Mm MaxBelow Grade Installations VentING installationTo be installed around the termination area VentNG installation Vertical through-the-roof applica- tionsFlat ceiling installation Installation for vertical termina- tionExample Termination Heights for Vents Above Flat or Sloped Roofs Installing gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Propane/LPMillivolt Checking GAS Pressure and Electrical installation Millivolt Remote Wall Switch Installation Remote Wall mounted SwitchDo not connect wall switch to a 110V circuit Optional Fan/Blower System BlotkhlMillivolt Optional FAN/BLOWER System WA RNI GNBlower Access Covers Millivolt Operating Instructions What to do if YOU Smell GASInitial lighting Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flameLighting the burner Main burner switchPilot position Optional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beJunction BOX Wiring Command Center Wall InstallationWall Switch Installation Do not connect wall switch to 110Electrical Installation Signature command Optional fan blower system Blotkhlsc Signature Command BlowerSignature command Operating Instructions Command Center OPERATing InstructionsBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Self Diagnostics Chart Command Center OperationsFunction Operation Due to the sensitive temperature monitoring Perature before accurate room temperaturesFor accurate temperature readings to appear on Turn appliance OFF at the Master Switch ifSetting Privacy Code on Transmitter Do not use two 2 or more remote control sysCode setting, as they will communicate with Resetting the transmitterThermostat Mode Timer ModeSmart Mode Option for Thermostat Mode Figure Blower Speed Control Blower On Delay Time and Off Delay Time Setup FigureLight Brightness Control Setting up Blank Screen or Constant Display in Idle Safety FeaturesAUX Control Rear Burner On/Off Control Using the Mounting Base Symptom Causes ActionGlass removal Glass Frame RemovalBRICK, light bulb, and lens placement Final installationRock wool placement Log placement LOG placementPlace the upper right rear log over the rear log Cleaning and maintenance Burner, Pilot and Control Compart- mentCleaning and maintenance Vent SysteMGlass Door LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause Troubleshooting Signature Command System TroubleshootingReplacement Parts Firebox components and accessoriesAccessories / Field Installed Options Description QtyReplacement Parts Standing Pilot Millivolt controlFuel Conversion Kits Millivolt Control Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Current Old Simpson Duravent Venting Components for 5xOr Mhsc Selkirk Box Description Requirements for the Commonwealth of Massachusetts Manufacturer RequirementsFive Year Warranty Lifetime WarrantyBasic Warranty Mhsc Model EnerGuide Ratings
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.