Monessen Hearth KHLDV400 PRE-INSTALLATION Information, Before You Start, Firebox framing

Page 7

pRE-INSTALLATION INFORMATION

KHLDV Series Gas Fireplace

Before You Start

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:

Fireplace (Firebox and Burner System)

Log Set

Rock Wool

Noncombustible Panel

ITEMS REQUIRED FOR INSTALLATION

Phillips Screwdriver

Framing Materials

Hammer

Wall Finishing Materials

Saw and/or saber saw Level

Measuring Tape

Pliers

Electric Drill and Bits

Square

Pipe Wrench

Tee Joint

Noncombustible finishing material or dura-rock*

Caulking Material (noncombustible)

Fireplace Surround Material (noncombustible)

Piping Complying with Local Codes

Pipe Sealant Approved for use with Propane/LPG

(Resistant to sulfur compounds)

*Only used if desired to cover painted face other than using tiles or marble. If tiles or marble are used around the face then the non-combustible material is not needed.

firebox framing

Firebox framing can be built before or after the appliance is set in place. Refer to Figure 2 for firebox dimensions and framing. Construct firebox framing following Figure 2 for your specific installation requirements. The framing headers may rest on the top of the firebox standoffs. Do not bring headers below top of standoffs. NOTE: When planning your framing and installation, keep in mind that your gas line will come in on the right side of the box (as you are facing it) and your electricity will come in on the left side.

The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure.

WARNING

Unit framing is to be rectangular front to

 

 

back. Failure to do so will cause fire and

 

damage to property.

 

 

WARNING

Do not fill spaces around firebox with insulation or other materials. This could cause a fire.

NOTE

COLD CLIMATE INSULATION

If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and under the floor on which the appliance rests, if the floor is above ground level.

73D0024

Image 7
Contents Khldv Series Direct Vent Gas Fireplace Signature Command System Operation Instructions Operating Instructions Signature CommandOwner InstallerUtility gas wells. This gas is commonly Important Safety Information and Code ApprovalCode Approval Never connect unit to private nonGAS pressures Product featuresGas Specifications & Orifice Size High ElevationsKHLDV400 KHLDV500 Fireplace and Framing DimensionsCold Climate Insulation PRE-INSTALLATION InformationBefore You Start Firebox framingFireplace Location PRE-INSTALLATION InformationSide View ClearancesClearances to combustibles Mantel clearancesOver front face of fireplace Never install combustible materialsSECURe Fireplace to floor or framing Finishing MaterialLife Venting InstallationInstallation precautions Failure to follow these instructions will void WarrantyFor vertical termination Installation planningInstalling a vent system in an outside chase For horizontal terminationGeneral Venting Information Termination Location Canadian Installations1 US Installations2Outside Corner How To Use The Vent GraphAlways install horizontal venting on a level plane Vertical Sidewall InstallationStep 610 mm Mm Max VERTICAL/Horizontal termination configurationsBelow Grade Installations VentING installationTo be installed around the termination area Vertical through-the-roof applica- tions VentNG installationFlat ceiling installation Installation for vertical termina- tionExample Termination Heights for Vents Above Flat or Sloped Roofs Installing gas piping to fireplace / burner system location Fireplace installationCheck gas type Propane/LP Natural GasMillivolt Checking GAS Pressure and Electrical installation Optional Fan/Blower System Blotkhl Millivolt Remote Wall Switch InstallationRemote Wall mounted Switch Do not connect wall switch to a 110V circuitWA RNI GN Millivolt Optional FAN/BLOWER SystemBlower Access Covers Never use an open flame to check for gas leak Millivolt Operating InstructionsWhat to do if YOU Smell GAS Initial lightingNever check for gas leak with open flame Approved leak testing methodLighting the burner Main burner switchPilot position Or performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyDo not connect wall switch to 110 Junction BOX WiringCommand Center Wall Installation Wall Switch InstallationElectrical Installation Blotkhlsc Signature Command Blower Signature command Optional fan blower systemSignature command Operating Instructions OPERATing Instructions Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Self Diagnostics Chart Command Center OperationsFunction Operation Turn appliance OFF at the Master Switch if Due to the sensitive temperature monitoringPerature before accurate room temperatures For accurate temperature readings to appear onResetting the transmitter Setting Privacy Code on TransmitterDo not use two 2 or more remote control sys Code setting, as they will communicate withThermostat Mode Timer ModeSmart Mode Option for Thermostat Mode Figure Blower Speed Control Blower On Delay Time and Off Delay Time Setup FigureLight Brightness Control Setting up Blank Screen or Constant Display in Idle Safety FeaturesAUX Control Rear Burner On/Off Control Symptom Causes Action Using the Mounting BaseGlass Frame Removal Glass removalBRICK, light bulb, and lens placement Final installationRock wool placement LOG placement Log placementPlace the upper right rear log over the rear log Burner, Pilot and Control Compart- ment Cleaning and maintenanceLogs Cleaning and maintenanceVent SysteM Glass DoorStanding Pilot Ignition TroubleshootingPoSSIBLE Cause Troubleshooting Troubleshooting Signature Command SystemDescription Qty Replacement PartsFirebox components and accessories Accessories / Field Installed OptionsStanding Pilot Millivolt control Replacement PartsFuel Conversion Kits Millivolt Control Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Current Old Simpson Duravent Venting Components for 5xOr Mhsc Selkirk Box Description Manufacturer Requirements Requirements for the Commonwealth of MassachusettsFive Year Warranty Lifetime WarrantyBasic Warranty Model EnerGuide Ratings Mhsc
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.