Monessen Hearth KHLDV400, KHLDV500 Signature command Optional fan blower system

Page 33

signature command - Optional fan blower system

KHLDV Series Gas Fireplace

WARNING

Electrical Grounding Instructions: This

appliance is equipped with a three-prong

 

 

(grounding) plug for your protection against

 

shock hazard and should be plugged directly

 

into a properly grounded three-prong

 

receptacle.

 

 

 

 

 

The black and white wires on the AC box

NOTE

wiring harness are marked ‘Blower’, ‘Light’

and ‘Aux’. It is important to use the wires

marked ‘Blower’ or the control will not work

 

correctly.

 

 

WARNING

Electrical connections should only be performed by a qualified licensed electrician. Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service.

BLOTKHLSC SIGNATURE COMMAND BLOWER

 

To Junction Box

 

 

In Fireplace

 

 

 

AC Module

 

Light

{ WHITE

 

WHITE

BLACK

 

BLACK

BLACK

 

OptionalAUX

 

{ WHITE

 

 

GREEN

 

 

Connector

 

 

Pin To Control Box

 

 

Control Box

Blower (300w Max)

Figure 47 -

 

 

 

 

BLOTKHLSC Blower Wiring Diagram

The BLOTKHLSC Blower Kit requires the SCSACM A/C

Module and the TSFRSC remote to install and operate

this kit. Refer to blower instructions for installation and

remote instructions for operation.

FP2705

 

 

73D0024

33

Image 33
Contents Khldv Series Direct Vent Gas Fireplace Signature Command System Operation Instructions Operating Instructions Signature CommandOwner InstallerCode Approval Important Safety Information and Code ApprovalNever connect unit to private non Utility gas wells. This gas is commonlyGas Specifications & Orifice Size Product featuresHigh Elevations GAS pressuresKHLDV400 KHLDV500 Fireplace and Framing DimensionsBefore You Start PRE-INSTALLATION InformationFirebox framing Cold Climate InsulationFireplace Location PRE-INSTALLATION InformationClearances to combustibles ClearancesMantel clearances Side ViewSECURe Fireplace to floor or framing Never install combustible materialsFinishing Material Over front face of fireplaceInstallation precautions Venting InstallationFailure to follow these instructions will void Warranty LifeInstalling a vent system in an outside chase Installation planningFor horizontal termination For vertical terminationGeneral Venting Information Termination Location Canadian Installations1 US Installations2Outside Corner How To Use The Vent GraphVertical Sidewall Installation Always install horizontal venting on a level planeStep 610 mm Mm Max VERTICAL/Horizontal termination configurationsVentING installation Below Grade InstallationsTo be installed around the termination area Vertical through-the-roof applica- tions VentNG installationInstallation for vertical termina- tion Flat ceiling installationExample Termination Heights for Vents Above Flat or Sloped Roofs Fireplace installation Installing gas piping to fireplace / burner system locationCheck gas type Propane/LP Natural GasMillivolt Checking GAS Pressure and Electrical installation Remote Wall mounted Switch Millivolt Remote Wall Switch InstallationDo not connect wall switch to a 110V circuit Optional Fan/Blower System BlotkhlWA RNI GN Millivolt Optional FAN/BLOWER SystemBlower Access Covers What to do if YOU Smell GAS Millivolt Operating InstructionsInitial lighting Never use an open flame to check for gas leakNever check for gas leak with open flame Approved leak testing methodMain burner switch Lighting the burnerPilot position Electrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beCommand Center Wall Installation Junction BOX WiringWall Switch Installation Do not connect wall switch to 110Electrical Installation Blotkhlsc Signature Command Blower Signature command Optional fan blower systemSignature command Operating Instructions OPERATing Instructions Command CenterFeatures Battery InstallationCommand Center System CONFIGURATION/SETUP Key Combinations for System SettingsFunction Operation Default Setting Command Center Operations Self Diagnostics ChartFunction Operation Perature before accurate room temperatures Due to the sensitive temperature monitoringFor accurate temperature readings to appear on Turn appliance OFF at the Master Switch ifDo not use two 2 or more remote control sys Setting Privacy Code on TransmitterCode setting, as they will communicate with Resetting the transmitterTimer Mode Thermostat ModeSmart Mode Option for Thermostat Mode Figure Blower On Delay Time and Off Delay Time Setup Figure Blower Speed ControlLight Brightness Control Safety Features Setting up Blank Screen or Constant Display in IdleAUX Control Rear Burner On/Off Control Symptom Causes Action Using the Mounting BaseGlass Frame Removal Glass removalFinal installation BRICK, light bulb, and lens placementRock wool placement LOG placement Log placementPlace the upper right rear log over the rear log Burner, Pilot and Control Compart- ment Cleaning and maintenanceVent SysteM Cleaning and maintenanceGlass Door LogsTroubleshooting Standing Pilot IgnitionPoSSIBLE Cause Troubleshooting Troubleshooting Signature Command SystemFirebox components and accessories Replacement PartsAccessories / Field Installed Options Description QtyStanding Pilot Millivolt control Replacement PartsAccessories Fuel Conversion Kits Millivolt Control Natural Gas to LPLP to Natural Gas Signature Command System KHLDV400 KHLDV500 Logs VENTing components Venting Components for 5x Current Old Simpson DuraventOr Mhsc Selkirk Box Description Manufacturer Requirements Requirements for the Commonwealth of MassachusettsLifetime Warranty Five Year WarrantyBasic Warranty Model EnerGuide Ratings Mhsc
Related manuals
Manual 1 pages 58.97 Kb Manual 1 pages 53.14 Kb

KHLDV500, KHLDV400 specifications

The Monessen Hearth KHLDV400 is a high-performance gas fireplace designed to provide both warmth and aesthetic appeal to any living space. This unit is engineered with modern technology, making it an excellent choice for homeowners looking to enhance their home’s atmosphere while enjoying the benefits of efficient heating.

One of the standout features of the KHLDV400 is its impressive heating capability. With an input of 40,000 BTUs, this gas fireplace is capable of heating spaces effectively, making it perfect for medium to large rooms. This fireplace utilizes a direct vent system, ensuring that combustion gases are efficiently expelled outside, while fresh air is drawn from the exterior to support the flame. This makes for a safe and environmentally friendly operation, as it minimizes indoor air pollution.

The KHLDV400 also boasts an innovative burner design that creates realistic flames, mimicking the look of traditional wood-burning fires. The fireplace comes with a choice of decorative media options, including glowing embers and fire glass, allowing homeowners to customize the look of their fireplace to match their personal style.

Another notable characteristic of the KHLDV400 is its intuitive control system. It can be operated via a handheld remote or wall switch, providing convenience and ease of use. Homeowners can adjust the flame height and heat output with simple controls, ensuring comfort at all times. Additionally, it features a standing pilot option that enhances its reliability and safety during operation.

Durability and quality craftsmanship are hallmarks of the Monessen brand, and the KHLDV400 is no exception. The fireplace is built with high-quality materials designed to withstand the test of time. Its sleek, contemporary design features a clean-face appearance that enhances any decor, while the glass front allows for an unobstructed view of the beautiful flame display.

With its combination of style, advanced technology, and efficient heating capabilities, the Monessen Hearth KHLDV400 is an exceptional choice for those looking to invest in a gas fireplace that delivers both performance and elegance to their home.