Fujitsu Remote Controller, UTB-UUB Vertical air direction adjustment Swing operation, Follows

Page 5

OPERATION

To set the operation mode

Vertical air direction adjustment (Swing operation)

 

 

 

 

 

* Press the START/STOP button to start the air conditioner, and then proceed as

 

 

 

 

 

 

 

 

 

 

follows.

 

 

 

 

 

Press the VERTICAL AIRFLOW DIRECTION button to adjust the direction of the verti-

 

 

 

 

 

cal airflow. To set the swing operation, press the VERTICAL AIRFLOW DIRECTION

 

 

 

 

 

 

 

 

 

 

button for more than 2 seconds. (Stop the setting by pressing for more than 2 sec-

 

 

 

 

 

ex. Vertical swing operation

onds again.)

Horizontal air direction adjustment (Swing operation)

* Press the START/STOP button to start the air conditioner, and then proceed as follows.

Press the HORIZONTAL AIRFLOW DIRECTION button to adjust the direction of the horizontal airflow. To set the swing operation, press the HORIZONTAL AIRFLOW DIRECTION button for more than 2 seconds. (Stop the setting by pressing for more

ex. Horizontal swing operation than 2 seconds again.)

NOTES

(1)• Always use the remote controller’s AIRFLOW DIRECTION button. Attempting to move the air direction louvers manually could result in improper operation; in this case, stop operation and restart.

The flaps should begin to operate properly again.

During cooling operation, do not set the vertical airflow direction louver in the downward position for an ex- tended period. Water vapor may condense near the out- let port and drops of water may drip from the air condi- tioner.

(2)• The range of swing is relative to the currently set airflow direction.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

(3)The swing operation is not available depending on the model. Please refer to the operating manual for the in- door unit.

<Vertical airflow swing operation>

 

Airflow direction

Range of swing

 

 

1

1 to 3

 

1

2

2 to 4

 

2

3

2 to 4

 

3

4

1 to 4 (All range)

 

 

 

 

 

 

4

<Horizontal airflow swing operation>

 

Airflow direction

Range of swing

 

 

11 to 5 (All range)

2

1 to 3

1 2 3 4 5

32 to 4

43 to 5

51 to 5 (All range)

IMPORTANT: Depending on the indoor unit model, the actual adjustment ranges of the airflow direction may be different from the ranges listed in the tables above. For more information, refer to the operating manual of the indoor unit.

En-4

Image 5
Contents Français English Operating ManualName of Parts ContentsSafety Precautions Function Information Preparatory Operation To set the operation modeOperation To set the current day and timeFollows Vertical air direction adjustment Swing operationHorizontal air direction adjustment Swing operation Room temperature sensor selection ON/OFF TimerTo set the ON/OFF timer To cancel the timer modeTo set the Weekly timer Weekly TimerDay of the week setting Time settingTo cancel To start/cancal the Weekly timer operationTo set the DAY OFF for a holiday To startTo set the temperature SET Back timer Temperature SET Back TimerTo start/cancel the temperature SET Back timer operation Day setting Operating time settingOperating Tips SELF-DIAGNOSISSymptom Cause and Action TroubleshootingSpecifications Sommaire Precautions DE SecuriteNomenclature DES Organes AffichageInformations Relatives AU Fonctionnement DE L’APPAREIL Preparatifs Réglage du mode de fonctionnementFonctionnement Réglage du jour et de l’heure actuelsFr-4 Minuterie DE Mise EN MARCHE/ARRET Annulation du mode MinuterieSélection du capteur de la température de la pièce Fonction de verrouillage de l’appareilProgrammation de la minuterie Hebdomadaire Minuterie HebdomadaireProgrammation du jour de la semaine Réglage de l’heureMise en marche Réglage du Jour Arret pour les vacancesAnnulation Suivez les mêmes procédures queRéglage du jour Minuterie D’ABAISSEMENT DE LA TemperatureRéglage de la température Réglage de l’heure de fonctionnementConseils D’UTILISATION AUTO-DIAGNOSTICSymptômes Cause et Action DepannageFiche Technique Precauciones DE Seguridad ÍndiceDenominación DE LOS Componentes IndicadorInformación Sobre LAS Funciones Funcionamiento PreparativosPara fijar el día y hora actuales Activación/desactivación del funcionamientoDe aire y después lleve a cabo los siguientes pasos NotasTemporizador DE CONEXIÓN/DE Desconexión Para cancelar el modo de temporizadorSelección del sensor de temperatura de la habitación Función de bloqueo parcialPara ajustar el temporizador Semanal Temporizador SemanalAjuste del día de la semana Ajuste de la horaPara ajustar la desconexión de día durante un día festivo Para cancelarPara comenzar Ajuste del día siguientePara ajustar el temporizador de cambio de temperatura Temporizador DE Cambio DE LA TemperaturaAjuste de día Ajuste de la temperaturaConsejos Para EL Funcionamiento AutodiagnósticoEspecificaciones Localización DE AveríasSíntoma Causa y Acción Compruebe