Fujitsu Remote Controller manual Temperature SET Back Timer, To set the temperature SET Back timer

Page 9

TEMPERATURE SET BACK TIMER

Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only.

The timer function is not available depending on the model.

To set the temperature SET BACK timer

1

SET BACK

SU MO TU

WE TH FR SA

If there is no existing

 

 

 

 

 

 

 

 

 

 

 

SET BACK tempera-

 

 

 

 

ture setting, “- -” will

 

 

3 6 9

12 15 18 21

be displayed for the

 

 

 

 

temperature.

Press the SET BACK button to change to the SET BACK confirmation display. The SET BACK operating time and the set temperature will be displayed.

2 SET

Press the SET button for 2 seconds or more.

3

Day setting

 

Operating time setting

 

SU MO TU

WE TH FR SA

DAY

SET

SET

 

 

 

 

 

 

 

 

 

 

 

 

DAY OFF

 

 

 

3

6

9

12 15 18 21

 

2

 

4

 

 

 

 

 

1

3

ex. When setting all days together

Follow steps 3 and 4 in “To set the WEEKLY timer” (p. 6). The DELETE button is also used as described in the procedures for the weekly timer.

4

Temperature setting

Press the SET TEMPERATURE buttons to

 

set the temperature (from 48 °F to 88 °F).

 

SU MO TU WE TH FR SA

 

 

 

 

3

6

9

12 15 18 21

SET BACK

ON

84°F

OFF

ex. Operating time 3:00–10:00 P.M.

temperature

76°F

 

 

(15:00–22:00)

Normal

 

 

76°F

 

 

 

temperature

 

 

 

 

 

 

 

5 SET

Repeat steps 3 and 4. Press the SET button for 2 seconds or more to com- plete the temperature SET BACK timer settings.

To start/cancel the temperature SET BACK timer operation

To start

SET BACK

SU MO TU WE TH FR SA

To cancel

SET BACK

DELETE

 

 

1

2

ex. Display during SET BACK timer operation (The operating time will not be displayed.)

Press the SET BACK button. The SET BACK confirmation display appears for 5 seconds, and then the timer starts au- tomatically.

Press the SET BACK button, and then press the DELETE button while the SET BACK confirmation display is dis- played. Even if the SET BACK button is pressed again, the SET BACK timer will be cancelled.

NOTES

(1)The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.

(2)The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.

(3)The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.

(4)During the COOL/DRY mode, the air conditioner will operate at a minimum of 64 °F even if the SET BACK temperature is set to 62 °F or lower.

(5)The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET BACK confirmation display.)

(6)Room temperatures as low as 48, 52, and 56 °F cannot be set depending on the model.

En-8

Image 9
Contents Français English Operating ManualContents Safety PrecautionsName of Parts Function Information Preparatory Operation To set the operation modeOperation To set the current day and timeVertical air direction adjustment Swing operation Horizontal air direction adjustment Swing operationFollows Room temperature sensor selection ON/OFF TimerTo set the ON/OFF timer To cancel the timer modeTo set the Weekly timer Weekly TimerDay of the week setting Time settingTo cancel To start/cancal the Weekly timer operationTo set the DAY OFF for a holiday To startTo set the temperature SET Back timer Temperature SET Back TimerTo start/cancel the temperature SET Back timer operation Day setting Operating time settingOperating Tips SELF-DIAGNOSISTroubleshooting SpecificationsSymptom Cause and Action Sommaire Precautions DE SecuriteNomenclature DES Organes AffichageInformations Relatives AU Fonctionnement DE L’APPAREIL Preparatifs Réglage du mode de fonctionnementFonctionnement Réglage du jour et de l’heure actuelsFr-4 Minuterie DE Mise EN MARCHE/ARRET Annulation du mode MinuterieSélection du capteur de la température de la pièce Fonction de verrouillage de l’appareilProgrammation de la minuterie Hebdomadaire Minuterie HebdomadaireProgrammation du jour de la semaine Réglage de l’heureMise en marche Réglage du Jour Arret pour les vacancesAnnulation Suivez les mêmes procédures queRéglage du jour Minuterie D’ABAISSEMENT DE LA TemperatureRéglage de la température Réglage de l’heure de fonctionnementConseils D’UTILISATION AUTO-DIAGNOSTICDepannage Fiche TechniqueSymptômes Cause et Action Precauciones DE Seguridad ÍndiceDenominación DE LOS Componentes IndicadorInformación Sobre LAS Funciones Funcionamiento PreparativosPara fijar el día y hora actuales Activación/desactivación del funcionamientoDe aire y después lleve a cabo los siguientes pasos NotasTemporizador DE CONEXIÓN/DE Desconexión Para cancelar el modo de temporizadorSelección del sensor de temperatura de la habitación Función de bloqueo parcialPara ajustar el temporizador Semanal Temporizador SemanalAjuste del día de la semana Ajuste de la horaPara ajustar la desconexión de día durante un día festivo Para cancelarPara comenzar Ajuste del día siguientePara ajustar el temporizador de cambio de temperatura Temporizador DE Cambio DE LA TemperaturaAjuste de día Ajuste de la temperaturaConsejos Para EL Funcionamiento AutodiagnósticoEspecificaciones Localización DE AveríasSíntoma Causa y Acción Compruebe