Honeywell Ademco Security Systems AC Loss Report Code, Low Bat Report Code, Test Report Code

Page 29

 

FIELD

 

 

TITLE and EXPLANATION

 

 

 

 

 

 

 

 

 

 

AC Loss Report Code

 

*62

 

 

 

 

 

 

Enter the appropriate report code. Timing of this report is random with up to a 4-hour delay. If AC

 

 

 

 

restores before the report goes out, there is no “AC RESTORE” report.

 

 

 

 

UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations.

 

 

 

 

Low Bat Report Code

 

*63

 

 

 

 

 

 

Enter the appropriate report code; sent when a low-battery condition exists in the system’s battery.

 

 

 

 

UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations.

 

 

 

 

Test Report Code

 

*64

 

 

 

 

 

 

Enter the appropriate report code, which is sent periodically to test that the communicator and phone

 

 

 

 

lines are operational. Frequency of report is set in Scheduling mode (event 11) or by the following key

 

 

 

 

commands: installer code + [#] + 0 + 0 = test report sent every 24 hours

 

 

 

 

installer code + [#] + 0 + 1 = test report sent once per week

 

 

 

 

installer code + [#] + 0 + 2 = test report sent every 28 days

 

 

 

 

Each mode sets schedule 2 to the selected repeat option; first test report sent 12 hours after command.

 

 

 

 

NOTE: Make sure the Real-Time Clock is set to the proper time before entering the test report schedule

 

 

 

 

command to ensure that test reports are sent when expected. (see Setting the Real-Time Clock section).

 

 

 

 

UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations.

 

 

 

 

Open Report Code

 

*65

 

 

 

 

 

 

Enter the appropriate report code, which is sent upon disarming of the system.

 

 

 

 

UL: Required for UL commercial burglar alarm installations.

 

 

 

 

Arm Away/Stay Report Code

 

*66

 

 

 

 

 

 

Enter appropriate report code. NOTE: “OPEN” reports not sent if associated closing report is not enabled.

 

 

 

 

RF Trans. Low Batt. Report Code

 

*67

 

 

 

 

 

 

Enter the appropriate report code; sent when a wireless transmitter low-battery condition exists.

 

 

 

 

UL installations: must be enabled if wireless devices are used.

 

 

 

 

 

 

*68

 

 

Cancel Report Code

 

 

 

 

Enter the appropriate report code; sent upon disarming of the system after an alarm was reported.

VISTA-10PSIA:Default = code enabled

*69

Recent Closing Report VISTA-10PSIA only Always enabled. Field does not apply to other controls.

Similar to the Exit Error condition described in field *59, but occurs if any burglary zone is faulted within two minutes after the initial exit delay expires. Disarming the system within the two minutes stops the alarm sound and displays " ALARM CANCELED " or "CA" and the faulted zone number. No message is sent to the Central Monitoring Station.

If the system is not disarmed within two minutes, the alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the Central Monitoring Station (after dial delay expires).

 

*70

Alarm Restore Report Code

 

 

Enter the appropriate report code; sent when an alarm zone is restored to its non-faulted condition.

 

 

 

 

UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations.

 

 

Trouble Restore Report Code

 

*71

 

 

Enter the appropriate report code, which is sent when a trouble in a zone is restored

 

 

UL: Required for UL commercial burglar alarm installations.

 

 

Bypass Restore Report Code

 

*72

 

 

Enter the appropriate report code, which is sent when a zone that has been bypassed is unbypassed.

 

 

UL: Required for UL commercial burglar alarm installations.

 

 

AC Restore Report Code

 

*73

 

 

Enter the appropriate report code; sent when AC power has been restored after an AC power outage.

 

 

UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations.

 

 

Low Bat Restore Report Code

 

*74

 

 

Enter the appropriate report code; sent when a system low-battery condition is restored to normal.

 

 

UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations.

 

*75

RF Xmtr Low Batt. Restore Code

Enter the appropriate report code; sent when a trans. low battery is restored (new battery installed). UL installations: must be enabled if wireless devices are used. Required for UL commercial burglar alarm installations and required for residential fire alarm installations.

4-5

Image 29
Contents Ademco VISTA-10P Ademco VISTA-10PSIA Recommendations for Proper Protection Table Of Contents System Communication and Operation Menu Mode ProgrammingTesting the System Capabilities Features and Installation HighlightsFunctions Compatible DevicesImportant Installation Highlights Installer Please Read Mounting the PC Board Alone no RF Receiver Mounting and Wiring the ControlCabinet and Lock Mounting the PC Board and RF Receiver Mounting Board with RF ReceiverSupplementary Power optional Wiring to KeypadsKeypad Addresses Size MA or less 100 mA 300 mA 500 mA 600 mABackup Battery Wiring the AC TransformerWire Run Chart Distance from control Wire SizeMetal Cold Water Pipe AC Power Outlet GroundEarth Ground Wire Smoke Detectors Hardwire ZonesSmoke Detectors Normally Open Zones/ Normally Open Eolr ZonesRF Receiver No. of Zones Installing the RF ReceiverInstalling a 5800TM Module Transmitter Battery Life Installing the TransmittersInstalling a Keyswitch Keyswitch Wiring Connections Connecting Relay ModulesPhone Line/Phone Module Connections On-Board Trigger Connector with 4-Wire CableOn-Board Triggers Long Range Radio Connections Phone Module ProblemsRJ31X Audio Alarm Verification Connections AAV, listen-InProgramming Overview To enable keypadsAbout Programming KeypadsPager Programming Wireless Receiver, Transmitters, and Wireless Keys keyfobsFunction Keys Output DevicesZone Type Definitions Keyswitch No Alarm ResponseConfigurable Monitor ZoneLoading Factory Defaults/Initializing for Download Menu Mode Programming ∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82Exiting the Programming Mode Task ProcedureTable of Device Addresses Reports as†† Enabled By…Data Field Programming System Setup FieldsAbout Data Field Programming Programming Data FieldsZone Sounds & Timing Dialer Programming System Status Report Codes Alarm Restore Report Code Cancel Report CodeTrouble Restore Report Code Bypass Restore Report CodeMiscellaneous System Fields Event Log Full Report Code Event Log EnablesOption Selection No. of Reports In Armed Period per Zone Swinger SuppressionPager Programming Fields Configurable Zone Type Configurable Zone Type Programming FieldsConfigurable Zone Type Options Zone Type 90 Report CodesZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Installation Instructions Zone Programming Procedure Menu Mode ProgrammingZone Programming Overview ∗56 and ∗58 Menu Modes SET to CONFIRM? 0 = no 1 = YESInput S/N L Input Type RF TransInput S/N Xmit to ConfirmProgram ALPHA? 0 = no 1 = YES ∗58 Expert Programming Mode ProceduresCompleting Zone Programming Template ? Wireless Key Programming TemplatesRC in L Wireless Key Transmitter Wireless Key Predefined Default TemplatesInput S/N AXXX-XXXX Xmit to Confirm Press to SkipMenu Mode Output Device Mapping Output Device Programming Overview *79/*80 Menu Mode∗79 Menu Mode Output Device programming involves∗80 Menu Mode Menu Mode Defining Output FunctionsOutput Definition Components Prompt EntryE P Trig Menu Mode Zone List Overview ∗81 Menu ModeZone List Programming List No Used for…Programming Function Keys Function Key Programming Overview ∗57 Menu ModePress the desired function key, A-D Is no longer available to be used as an endWhen defining descriptors About Descriptor Programming Overview ∗82 Menu ModeProgramming Zone Descriptors Menu mode ∗82 ZN 01 Back Door ZN 01 Back D OORZN 01 Back Door Custom?For Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSystem Operation section Programming Installer and User Schedules= group number Installation Instructions Report Code Formats System Communication and OperationSystem Communication Overview Code for Type +1/4+1 Report Standard Expanded WhereMaximum Ademco Contact IDCode Definition Level User No Functions Setting the Real-Time ClockUser Security Codes Keypad Functions Keypad CommandsVoice Keypads Function DescriptionAlpha Display Various System Trouble DisplaysMeaning Keys Displayed as ZoneAbout Test Procedures Testing the SystemChecking Transmitter Enrollment Sniffer Mode System TestAutomatic Standby Battery Tests Go/No Go Test ModeDialer Communication Test and Periodic Test Reports Automatic Periodic Test ReportRelay Module Specifications & AccessoriesPhone Modules Long Range RadioModel Product Input Type Description Series Transmitter Input Loop IdentificationCompatible 5800 Series Transmitters Table Can be used to turn the burglary protection on and off 5827 Wireless KeypadInstallation Instructions Federal Communications Commission FCC Part Industrie CanadaIndustry Canada FCC PartSIA Quick Reference Guide UL NoticesLimitations of this Alarm System Limitations and Warranty10-2 Index 10-4 Summary of Connections K0735V3 10/04 Rev. B Limited Warranty