Honeywell VISTA-10P ∗58 Expert Programming Mode Procedures, Completing Zone Programming

Page 39

E n t d A 0 2 2 - 4 0 6 3 1 R c v d A 0 2 2 - 4 0 6 4 1

If the serial number transmitted does not match the serial number entered, a display similar to the one shown appears. If the loop number does not match, it will also be displayed.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter (or transmit) the correct serial number.

[∗] to continue

Zn ZT RC In: L

10 03 10 RF: 1s

If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and a summary display will appear, showing that zone's programming. An “s” indicates that a transmitter’s serial number has been enrolled.

[∗] to accept the zone information and continue

PROGRAM ALPHA? 0 = NO 1 = YES 0

If you want to program descriptors for the zone now, enter 1 (yes) and refer to the *82 Descriptor Programming section for procedures.

To program descriptors later, enter 0 (no). [∗] to continue

ENTER ZN NUM. (00 = QUIT) 11

If 0 (No) was entered at the Program Alpha prompt, the system will return you to the ZONE NUMBER prompt. Repeat these steps for each zone in the system.

When all zones have been programmed, enter 00 as the zone number to quit. [∗] to continue

Completing Zone Programming

When you have finished programming all zones, test each zone using the system’s TEST mode. Do not use the Transmitter ID Sniffer Mode for checking wireless transmitting devices, as it will only check for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop.

NOTE: Following the successful enrollment of each wireless device, note the device serial number in the appropriate column on the ENROLLED TRANSMITTERS worksheet in the Programming Form; then enter the other information (zone number, zone type, loop number, etc.) relevant to that device.

58 Expert Programming Mode Procedures

This method is designed for use by installers with previous experience in programming ADEMCO control panels. This mode is also used to program wireless keys using pre-defined templates.

Start Expert Programming mode by pressing 58 while in Data Programming mode. The following prompts are displayed:

 

PROMPT

VALID ENTRIES

EXPLANATION

 

 

 

 

SET TO CONFIRM? 0 = NO 1 = YES

We recommend that you select “yes” to confirm the programming of every transmitter. If selected, a prompt appears after entering the serial and loop numbers to confirm each transmitter)

Zn ZT RC HW: RT

01 09 10 EL 1

Zn ZT RC IN: L

10 – – – :

A summary screen will appear, showing zone 1’s currently programmed values.

Enter the zone number being programmed, then press [∗]. In this example, zone 10 is being entered

(see Zone Number prompt in *56 Menu Mode for zone numbers).

[D] = for assigning wireless key programming templates (see Wireless Key Programming Templates section in i/i); lets you choose from a series of preset templates for easy programming of wireless key zones

00 = quit (when all zones have been programmed, press “00” to quit this menu mode) [∗] to continue

5-3

Image 39
Contents Ademco VISTA-10P Ademco VISTA-10PSIA Recommendations for Proper Protection Table Of Contents Menu Mode Programming Testing the SystemSystem Communication and Operation Compatible Devices Features and Installation HighlightsCapabilities FunctionsImportant Installation Highlights Installer Please Read Mounting and Wiring the Control Cabinet and LockMounting the PC Board Alone no RF Receiver Mounting the PC Board and RF Receiver Mounting Board with RF ReceiverSize MA or less 100 mA 300 mA 500 mA 600 mA Wiring to KeypadsSupplementary Power optional Keypad AddressesDistance from control Wire Size Wiring the AC TransformerBackup Battery Wire Run ChartAC Power Outlet Ground Earth GroundMetal Cold Water Pipe Normally Open Zones/ Normally Open Eolr Zones Hardwire ZonesWire Smoke Detectors Smoke DetectorsInstalling the RF Receiver Installing a 5800TM ModuleRF Receiver No. of Zones Installing the Transmitters Installing a KeyswitchTransmitter Battery Life Keyswitch Wiring Connections Connecting Relay ModulesOn-Board Trigger Connector with 4-Wire Cable On-Board TriggersPhone Line/Phone Module Connections Long Range Radio Connections Phone Module ProblemsRJ31X Audio Alarm Verification Connections AAV, listen-InKeypads To enable keypadsProgramming Overview About ProgrammingOutput Devices Wireless Receiver, Transmitters, and Wireless Keys keyfobsPager Programming Function KeysZone Type Definitions Monitor Zone No Alarm ResponseKeyswitch ConfigurableTask Procedure Menu Mode Programming ∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82Loading Factory Defaults/Initializing for Download Exiting the Programming ModeTable of Device Addresses Reports as†† Enabled By…Programming Data Fields System Setup FieldsData Field Programming About Data Field ProgrammingZone Sounds & Timing Dialer Programming System Status Report Codes Bypass Restore Report Code Cancel Report CodeAlarm Restore Report Code Trouble Restore Report CodeMiscellaneous System Fields No. of Reports In Armed Period per Zone Swinger Suppression Event Log EnablesEvent Log Full Report Code Option SelectionPager Programming Fields Zone Type 90 Report Codes Configurable Zone Type Programming FieldsConfigurable Zone Type Configurable Zone Type OptionsZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Installation Instructions SET to CONFIRM? 0 = no 1 = YES Menu Mode ProgrammingZone Programming Procedure Zone Programming Overview ∗56 and ∗58 Menu ModesXmit to Confirm Input Type RF TransInput S/N L Input S/N∗58 Expert Programming Mode Procedures Completing Zone ProgrammingProgram ALPHA? 0 = no 1 = YES Wireless Key Programming Templates RC in LTemplate ? Xmit to Confirm Press to Skip Wireless Key Predefined Default TemplatesWireless Key Transmitter Input S/N AXXX-XXXXOutput Device programming involves Output Device Programming Overview *79/*80 Menu ModeMenu Mode Output Device Mapping ∗79 Menu ModePrompt Entry Menu Mode Defining Output Functions∗80 Menu Mode Output Definition ComponentsE P Trig List No Used for… Zone List Overview ∗81 Menu ModeMenu Mode Zone List ProgrammingIs no longer available to be used as an end Function Key Programming Overview ∗57 Menu ModeProgramming Function Keys Press the desired function key, A-DAbout Descriptor Programming Overview ∗82 Menu Mode Programming Zone Descriptors Menu mode ∗82When defining descriptors Custom? ZN 01 Back D OORZN 01 Back Door ZN 01 Back DoorFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSystem Operation section Programming Installer and User Schedules= group number Installation Instructions System Communication and Operation System Communication OverviewReport Code Formats Code for Type +1/4+1 Report Standard Expanded WhereAdemco Contact ID Code DefinitionMaximum Setting the Real-Time Clock User Security CodesLevel User No Functions Function Description Keypad CommandsKeypad Functions Voice KeypadsKeys Displayed as Zone Various System Trouble DisplaysAlpha Display MeaningSystem Test Testing the SystemAbout Test Procedures Checking Transmitter Enrollment Sniffer ModeAutomatic Periodic Test Report Go/No Go Test ModeAutomatic Standby Battery Tests Dialer Communication Test and Periodic Test ReportsLong Range Radio Specifications & AccessoriesRelay Module Phone ModulesSeries Transmitter Input Loop Identification Compatible 5800 Series Transmitters TableModel Product Input Type Description Can be used to turn the burglary protection on and off 5827 Wireless KeypadInstallation Instructions FCC Part Industrie CanadaFederal Communications Commission FCC Part Industry CanadaSIA Quick Reference Guide UL NoticesLimitations of this Alarm System Limitations and Warranty10-2 Index 10-4 Summary of Connections K0735V3 10/04 Rev. B Limited Warranty