S E C T I O N 8

Specifications & Accessories

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

SECURITY CONTROL

Physical: 12-1/2” W x 14-1/2” H x 3” D (318mm x 368mm x 76mm)

Electrical:

VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No. 1321 (in U.S.A.)

RECHARGEABLE BACKUP BATTERY: 12VDC, 4AH (sealed lead acid type). Charging Voltage: 13.8VDC.

ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V BELLS or can drive one or two 702 (series connected) self-contained 20-watt sirens.

Do not connect two 702s in parallel.

AUXILIARY POWER OUTPUT: 12VDC, 600mA max.

NOTE: For UL installations, Alarm Sounder plus Auxiliary Power currents should not exceed 600mA total.

FUSE: Battery (3A) No. 90–12

Maximum Zone Resistance: Zones 1–8 = 300 ohms excluding EOLR standard zones

Communication:

FORMAT SUPPORTED:

ADEMCO Express: 10 characters/sec, DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF.

ADEMCO Low Speed: 10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.

Radionics/SESCOA: 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Can report 0-9, B-F

Ademco Contact ID 10 characters/sec., DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF.

LINE SEIZE: Double Pole

RINGER EQUIVALENCE: 0.1B

FCC REGISTRATION No.: 5GBUSA-44003-AL-E

COMPATIBLE DEVICES

Keypads:6150, 6160, 6150V, 6160V

Wireless Receivers: 5881L/5882L: accepts up to 8 transmitters 5881M/5882M: accepts up to 16 transmitters

5800TM Transmitter Module (used with 5827BD Wireless 2-Way Keypad) 5883 Transceiver: accepts up to system maximum transmitters 6150RF Keypad/Transceiver: accepts up to system maximum transmitters

Relay Module:

4204 RELAY MODULE

Phone Modules:

4285 PHONE MODULE

Long Range Radio

4286VIP PHONE MODULE

7835C/7845C

Sounders:

Ademco AB-12M 10” Motorized Bell & Box

 

Ademco 1011BE12M 10” Motorized Bell & Box

 

Ademco 702

Outdoor Siren

 

Ademco 719

2-Channel Siren

 

Ademco 747

Indoor Siren

 

Ademco 747UL Indoor Siren

 

Ademco 744

Siren Driver

 

Ademco 745X3 Voice Siren Driver

 

Ademco 705-820, 5-inch Round Speaker

Ademco 713 Speaker

System Sensor PA400B (beige)/; PA400R (red) Indoor Piezo Sounder

8-1

Image 61
Contents Ademco VISTA-10P Ademco VISTA-10PSIA Recommendations for Proper Protection Table Of Contents Testing the System Menu Mode ProgrammingSystem Communication and Operation Capabilities Features and Installation HighlightsFunctions Compatible DevicesImportant Installation Highlights Installer Please Read Cabinet and Lock Mounting and Wiring the ControlMounting the PC Board Alone no RF Receiver Mounting the PC Board and RF Receiver Mounting Board with RF ReceiverSupplementary Power optional Wiring to KeypadsKeypad Addresses Size MA or less 100 mA 300 mA 500 mA 600 mABackup Battery Wiring the AC TransformerWire Run Chart Distance from control Wire SizeEarth Ground AC Power Outlet GroundMetal Cold Water Pipe Wire Smoke Detectors Hardwire ZonesSmoke Detectors Normally Open Zones/ Normally Open Eolr ZonesInstalling a 5800TM Module Installing the RF ReceiverRF Receiver No. of Zones Installing a Keyswitch Installing the TransmittersTransmitter Battery Life Keyswitch Wiring Connections Connecting Relay ModulesOn-Board Triggers On-Board Trigger Connector with 4-Wire CablePhone Line/Phone Module Connections Long Range Radio Connections Phone Module ProblemsRJ31X Audio Alarm Verification Connections AAV, listen-InProgramming Overview To enable keypadsAbout Programming KeypadsPager Programming Wireless Receiver, Transmitters, and Wireless Keys keyfobsFunction Keys Output DevicesZone Type Definitions Keyswitch No Alarm ResponseConfigurable Monitor ZoneLoading Factory Defaults/Initializing for Download Menu Mode Programming ∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82Exiting the Programming Mode Task ProcedureTable of Device Addresses Reports as†† Enabled By…Data Field Programming System Setup FieldsAbout Data Field Programming Programming Data FieldsZone Sounds & Timing Dialer Programming System Status Report Codes Alarm Restore Report Code Cancel Report CodeTrouble Restore Report Code Bypass Restore Report CodeMiscellaneous System Fields Event Log Full Report Code Event Log EnablesOption Selection No. of Reports In Armed Period per Zone Swinger SuppressionPager Programming Fields Configurable Zone Type Configurable Zone Type Programming FieldsConfigurable Zone Type Options Zone Type 90 Report CodesZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Installation Instructions Zone Programming Procedure Menu Mode ProgrammingZone Programming Overview ∗56 and ∗58 Menu Modes SET to CONFIRM? 0 = no 1 = YESInput S/N L Input Type RF TransInput S/N Xmit to ConfirmCompleting Zone Programming ∗58 Expert Programming Mode ProceduresProgram ALPHA? 0 = no 1 = YES RC in L Wireless Key Programming TemplatesTemplate ? Wireless Key Transmitter Wireless Key Predefined Default TemplatesInput S/N AXXX-XXXX Xmit to Confirm Press to SkipMenu Mode Output Device Mapping Output Device Programming Overview *79/*80 Menu Mode∗79 Menu Mode Output Device programming involves∗80 Menu Mode Menu Mode Defining Output FunctionsOutput Definition Components Prompt EntryE P Trig Menu Mode Zone List Overview ∗81 Menu ModeZone List Programming List No Used for…Programming Function Keys Function Key Programming Overview ∗57 Menu ModePress the desired function key, A-D Is no longer available to be used as an endProgramming Zone Descriptors Menu mode ∗82 About Descriptor Programming Overview ∗82 Menu ModeWhen defining descriptors ZN 01 Back Door ZN 01 Back D OORZN 01 Back Door Custom?For Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSystem Operation section Programming Installer and User Schedules= group number Installation Instructions System Communication Overview System Communication and OperationReport Code Formats Code for Type +1/4+1 Report Standard Expanded WhereCode Definition Ademco Contact IDMaximum User Security Codes Setting the Real-Time ClockLevel User No Functions Keypad Functions Keypad CommandsVoice Keypads Function DescriptionAlpha Display Various System Trouble DisplaysMeaning Keys Displayed as ZoneAbout Test Procedures Testing the SystemChecking Transmitter Enrollment Sniffer Mode System TestAutomatic Standby Battery Tests Go/No Go Test ModeDialer Communication Test and Periodic Test Reports Automatic Periodic Test ReportRelay Module Specifications & AccessoriesPhone Modules Long Range RadioCompatible 5800 Series Transmitters Table Series Transmitter Input Loop IdentificationModel Product Input Type Description Can be used to turn the burglary protection on and off 5827 Wireless KeypadInstallation Instructions Federal Communications Commission FCC Part Industrie CanadaIndustry Canada FCC PartSIA Quick Reference Guide UL NoticesLimitations of this Alarm System Limitations and Warranty10-2 Index 10-4 Summary of Connections K0735V3 10/04 Rev. B Limited Warranty